Operation Manual
Check Y.Mito
Author F.Ogawa
2012/7/2
9/19
.
SPD-1207001
V
i
s
i
on Sens
i
ng Co. Ltd
4.3: About a trigger input pin outside the 4.3: and the outside control pulsed output pin.
External trigger input equivalent circuit.
・photo coupler "PS2805-4 (NEC)".
・Please usually make the pulse of 5V course an input signal.
External digital output equivalent circuit.
・photo coupler "PS2805-4 (NEC)".
・Be careful for electrical polarity.
Camera
inside
OUT 0
or
OUT 1
OUT 0 COMMON
or
OUT 1 COMMON
Internal output
PS2805-4[NEC]