![Vision Fitness T80 Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/vision-fitness/t80/t80_service-manual_1032002030.webp)
30
3.7 TROUBLESHOOTING – Heart Rate Issues
1) SYMPTOM:
a. The console does not display the heart rate when holding the heart rate grips.
2) SOLUTION:
a. First check if the heart rate grip is well-connected, not broken / damaged. Replace the HR grip / wiring as needed.
b. Confirm whether the heart rate board is well-connected with the UCB.
c. If well-connected, replace the heart rate board. If heart rate still does not work, replace the console.
CHAPTER 3: Troubleshooting
Heart Rate Board
connected to the UCB
Heart Rate Board
Содержание T80
Страница 1: ...1 Vision Fitness T80 Frame with Classic Elegant Touch Console Service Manual ...
Страница 3: ...3 CHAPTER 1 Serial Number Location 1 1 1 SERIAL NUMBER LOCATION T80 ...
Страница 23: ...23 CHAPTER 3 Troubleshooting 3 1 ELECTRICAL DIAGRAMS 3 1 1 Electrical Diagram TM Classic Console ...
Страница 24: ...24 3 1 2 Electrical Diagram TM Elegant Console 10inch LCD Console No Touch Panel ...
Страница 25: ...25 3 1 3 Electrical Diagram TM Touch Console 15inch LCD Console Touch Panel ...
Страница 28: ...28 3 4 T80 MCB SWITCH SETTING DEFINITION CHAPTER 3 Troubleshooting ...