Страница 2: ...4 Engineering Mode Overview Touch Console 14 CHAPTER 3 TROUBLESHOOTING 3 1 ELECTRICAL DIAGRAMS 23 3 2 MCB WIRING INSTRUCTIONS 26 3 3 MCB LED PLACEMENT AND DEFINITIONS 27 3 4 MCB SWITCH SETTING DEFINITION 28 3 5 Troubleshooting Machine Will Not Start 29 3 6 Troubleshooting Touch Panel Issues 29 3 7 Troubleshooting Heart Rate Issues 30 3 8 Troubleshooting iPod Issues 31 3 9 Troubleshooting Speaker A...

Страница 3: ...3 CHAPTER 1 Serial Number Location 1 1 1 SERIAL NUMBER LOCATION T80 ...

Страница 4: ...4 CHAPTER 1 Serial Number Location 1 1 2 SERIAL NUMBER LOCATION Touch Elegant Classic Console Touch Elegant Classic ...

Страница 5: ...ds until Engineering Menu appears on the display 2 Use the INCLINE and SPEED UP and DOWN keys to select a parameter 3 Press ENTER to enter a parameter setting 4 Use the INCLINE and SPEED UP and DOWN keys to change the parameter 5 Press the START key to save the change to the parameter 6 Press and hold the STOP key to exit Engineering Mode and return to normal operation ...

Страница 6: ... the ENTER key to enter the Language setting Use the INCLINE or SPEED UP and DOWN keys to select the languages English German Dutch French will scroll on the middle window ENG 4 Information Accumulated Time Distance and Aged Press and hold the START key for 5 seconds to clear all data Remarks Unit of Time is Hour Unit of Distance is KM or Mile Unit of Aged is Minute factory only setting ENG 5 Set ...

Страница 7: ...he same time for 3 5 seconds until Engineering Menu appears on the display 2 The Engineering Mode parameter list will be displayed on the screen 3 Press the ATM style key on either side of the screen to enter the appropriate screen settings 4 Set all the information using the ATM style keys 5 Press and hold the STOP key to exit Engineering Mode ...

Страница 8: ...t Descriptions Modified Accumulated Data Accumulated Distance Total distance displayed in native units miles or kilometers not editable Cannot be modified Accumulated Time Total time not editable Cannot be modified Main Board Information UI Software Version Application version not editable Cannot be modified IO Version Sub UCB software version not editable Cannot be modified OS Version Operation S...

Страница 9: ... to enter the next page of settings Set these settings the same way as Machine Type NOTE After changing a setting on any page select Finished to complete the setup the other items will keep the default settings press Restore to restore to the factory settings 2 4 3 ENGINEERING MODE Elegant Console Test Tab The Test Tab includes various tests of the functions of the unit Go UP and DOWN to choose ...

Страница 10: ...ole The console will cycle between red green and blue when the Continue key is selected Hardware Test This tab allows a service technician to test the RPM sensor and or the incline motor Changing a setting should cause the belt and or the incline motor to operate ...

Страница 11: ...des options for setting Max Workout Time Default Workout Time Warm up Time Cool Down Time and Pause Time Press the key next to Continue to enter the next page of defaults Set these defaults using the arrow keys NOTE After changing a setting on any page select Finished to complete the setup the other items will keep the default settings select Restore to restore to the factory settings ...

Страница 12: ...s settings for Month Day Year Time hour minute Language Country and Units miles kilometers Press the key next to Continue to enter the next page of region settings Set these region settings using the arrow keys NOTE After changing a region setting on any page select Finished to complete the setup the other items will keep the default region settings select Restore to restore to the factory setting...

Страница 13: ...13 2 4 7 ENGINEERING MODE Elegant Console Service Log Tab The Service Log Tab allows the club service provider to keep track of the service history ...

Страница 14: ...rners of the touch screen from 1 4 as shown below 2 An Engineering Mode parameter list will be displayed on the screen 3 Select the parameter by touching the parameter list 4 Set all information using the Touch panel 5 Press the Home key to save the change to the parameter and exit the Engineering Mode 1 2 3 4 ...

Страница 15: ... native units miles or kilometers not editable Cannot be modified Accumulated Time Total time not editable Cannot be modified Main Board Information UI Software Version Application version not editable Cannot be modified IO version Sub UCB software version not editable Cannot be modified OS Version Operation system version not editable Cannot be modified MCB Information MCB Type The frame MCB type...

Страница 16: ...PTICAL or BIKE Use the same procedure as Machine Type to set the Model Type Energy Saver First Boot and Program Speed 2 6 3 ENGINEERING MODE Touch Console Default Tab The Default Tab displays the default information of the console such as Workout Time Weight Age etc Selecting the data that needs to be set will bring up a slider to adjust the corresponding information Refer to the figure below auto...

Страница 17: ...imum 99 Minutes Minimum 5 Minutes Cool Down Time Default 5 minutes This option enables you to set users Cool Down Time after a workout Maximum 99 Minutes Minimum 5 Minutes Age Default Age Default 30 This option enables you to set the user s default age if not selected during setup Maximum 99 Minimum 13 Weight Default Weight Default 150LBS This option enables you to set user s default weight if not...

Страница 18: ...een or not On off Virtual Active Music VA Music Default on This option enables you to set the VA user can choose the VA music played or not On off Use the same operation as Max Workout Time to adjust the other Default information Press Restore to restore to the factory settings 2 6 4 ENGINEERING MODE Touch Console Region Tab The Region Tab is used to set Date Time Language Country and Units Touch ...

Страница 19: ... Tests the reliability of the LCD and Touch panel Display Test Touch panel Test Use your finger to draw a line following the instructions on the screen If the test fails selecting continue will bring the user directly into the calibration screen Refer to the figure below Display Test Key Test Audio Test Hardware Test ...

Страница 20: ... any key on the keypad to display the definition the function and the code of the key If there is no feedback check the keypad connection with the UCB Select Continue to exit the test d Audio Test When the Audio Test key is pressed the console should chime ...

Страница 21: ...the RPM Sensor Incline Motor and Heart Rate components Changing a setting should cause the belt incline motor or heart rate display to operate 2 6 6 ENGINEERING MODE Touch Console Error Log Tab The console will automatically show an error code history for the unit ...

Страница 22: ...22 2 6 7 ENGINEERING MODE Touch Console Service Log Tab The Service Log Tab allows the club service provider to keep track of the service history ...

Страница 23: ...23 CHAPTER 3 Troubleshooting 3 1 ELECTRICAL DIAGRAMS 3 1 1 Electrical Diagram TM Classic Console ...

Страница 24: ...24 3 1 2 Electrical Diagram TM Elegant Console 10inch LCD Console No Touch Panel ...

Страница 25: ...25 3 1 3 Electrical Diagram TM Touch Console 15inch LCD Console Touch Panel ...

Страница 26: ...B WIRING INSTRUCTIONS CN9 AC motor cable socket CN1 Input power cable socket CN13 External fan cable socket CN7 Digital communication cable socket CN6 Elevation motor cable socket CN8 Adaptor power cable socket CHAPTER 3 Troubleshooting ...

Страница 27: ...linking Normal Light MCU Fault Off MCU No Power DOWN LED2 Indicates if the console is commanding elevation down Light Normal Off No command from console received by the elevation motor UP LED3 Indicates if the console is commanding elevation up Light Normal Off No command from console received by the elevation motor 12V Indicates if the console voltage supply is present Light Normal Off 12 Volts a...

Страница 28: ...28 3 4 T80 MCB SWITCH SETTING DEFINITION CHAPTER 3 Troubleshooting ...

Страница 29: ...SOLUTION a If the touch screen is not accurate or has a slight deviation simply press the Enter and Stop keys to enter the screen calibration mode b If the touch screen calibration does not work check the touch screen for visible damage indentation or deformation If so replace the entire console c If not confirm whether the touch screen FPC wire is well connected with the main board d If well conn...

Страница 30: ...eck if the heart rate grip is well connected not broken damaged Replace the HR grip wiring as needed b Confirm whether the heart rate board is well connected with the UCB c If well connected replace the heart rate board If heart rate still does not work replace the console CHAPTER 3 Troubleshooting Heart Rate Board connected to the UCB Heart Rate Board ...

Страница 31: ...he figure below regarding the iPod cable and the iPod board c Check the FFC connect wire for damage If any is found replace the FFC wire d If the iPod still cannot connect replace the iPod PCB board e If the iPod still cannot connect after the iPod board was replaced replace the UCB CHAPTER 3 Troubleshooting iPod Wire iPod PCB Board FFC connect wire iPod FPC connected to the UCB FFC wire connected...

Страница 32: ...update the OS Software and IO Versions If the problem persists replace the UCB 3 8 2 Touch a If the speaker has no sound output confirm whether the speaker wire is well connected with the UCB b If well connected use a multi meter to confirm whether the audio output terminal switch is connected Refer to the figure below c If all wiring is well connected update the OS Software and IO Versions If the...

Страница 33: ...ect with the Passport 2 SOLUTION a Make sure that the RF and Passport connection key are functional see Key Test in Section 2 3 5 TM STOP Incline EP STOP Resistance b Confirm again whether the FFC connect wire is damaged c If above connections are all confirmed ok replace the RF board RF board FPC Connector FFC connected to the UCB ...

Страница 34: ... the Virtual Active VA files 2 SOLUTION a Confirm if the SD card is firmly seated on the UCB if not please re insert the SD card and use adhesive tape to fix it in place No Good OK b If the SD card is inserted correctly update the Software Versions c If the VA still cannot be played replace the UCB ...

Страница 35: ...CAB Touch console choose PremierGUIDeploy CAB Note The two files can not be placed together at the same time under the USB 3 Place the updadte config file on the USB flash drive 4 Start up the console and insert the USB flash drive into the slot in the front of the console The files will update automatically 4 2 UPDATING IO 1 IO Update Files BL_130 TXT PATCH TXT and IO1 TXT 2 Place the three files...

Отзывы: