manualshive.com logo in svg
background image

4

GROUNDING INSTRUCTIONS

The equipment must be grounded. If it should malfunction or breakdown, grounding 
provides a path of least resistance for electric current to reduce the risk of electric shock. 
The unit is equipped with a cord having an equipment-grounding conductor and a 
grounding plug. The plug must be plugged into an appropriate outlet that is properly 
installed and grounded in accordance with all local codes and ordinances. If the user does 
not follow these grounding instructions, the user could void the Vision limited warranty.

ADDITIONAL ELECTRICAL INFO

In addition to the dedicated circuit requirement, the proper gauge wire must be used 
from the circuit breaker box, to each outlet that will have the maximum number of 
units running off of it. If the distance from the circuit breaker box to each outlet, is 100 
ft (30.5 m) or less, then 12 gauge wire should be used. For distances greater than 100 
ft (30.5 m) from the circuit breaker box to the outlet, a 10 gauge wire should be used.

ENERGY SAVING / LOW-POWER MODE

All units are configured with the ability to enter into an energy saving / low-

power mode when the unit has not been in use for a specified period of 

time. Additional time may be required to fully reactivate this unit once it has 

entered the low-power mode. This energy saving feature may be enabled 

or disabled from within the ‘Manager Mode’ or ‘Engineering Mode.

POWER REQUIREMENTS

DEDICATED CIRCUIT AND ELECTRICAL INFO

A “Dedicated Circuit” means that each outlet you plug into should 
not have anything else running on that same circuit. The easiest 
way to verify this is to locate the main circuit breaker box, and turn 
off the breaker(s) one at a time. Once a breaker has been turned 
off, the only thing that should not have power to it are the units 
in question. No lamps, vending machines, fans, sound systems, or 
any other item should lose power when you perform this test.
Non-looped (isolated) neutral/grounding means that each circuit 
must have an individual neutral/ground connection coming from 
it, and terminating at an approved earth ground. You cannot 
“jumper” a single neutral/ground from one circuit to the next.

ELECTRICAL REQUIREMENTS

For your safety and to ensure good treadmill performance, 
the ground on this circuit must be non-looped (isolated). 
Please refer to NEC article 210-21 and 210-23. Your 
treadmill is provided with a power cord with a plug listed 
below and requires the listed outlet. Any alterations of this 
power cord could void all warranties of this product.

110 V UNITS

Vision 100-125 V / 18A * treadmills ( refer to current on 
regulation decal of machine) require the use of a 100-125 
V, 60 Hz and a 20 A “Dedicated Circuit”, with a non-looped 
(isolated) neutral/ground for power. This outlet should 
be a NEMA 5-20R and have the same configuration as the 
plug. No adapter should be used with this product.

220 V UNITS

All Vision 220 V treadmills require the use of a 216-250 V, 
50 Hz and a 20 A “Dedicated Circuit”, with a non-looped 
(isolated) neutral/ground for power. This outlet should 
be a NEMA 6-20R and have the same configuration as the 
plug. No adapter should be used with this product.
* Vision 100-125 V / 14A treadmills ( refer to current on 
regulation decal of machine)require the use of a 100-
125 

V, 60 Hz and a minimum 15 A “Dedicated Circuit”, with 

a non-looped (isolated) neutral/ground for power.

WARNING!

Connect this exercise product to a properly grounded outlet only.

• Never operate product with a damaged cord or plug even if it is working properly. 

Never operate any product if it appears damaged, or has been immersed 
in water. Contact Customer Tech Support for replacement or repair.

Failure to follow these specifications can cause damage 
to your product and can void the warranty:

• All video and power outlets must be functional the day of delivery / 

assembly of the product. The client is responsible for any additional 
installation charges associated with return visits.

• Electrical supply may fluctuate in your area. To ensure stable 

performance of the product, use the proper gauge wire.

DANGER!

Improper connection of the equipment-grounding conductor can result in a risk of 
electric shock. Check with a qualified electrician or serviceman if you are in doubt as to 
whether the product is properly grounded. Do not modify the plug provided with the 
product. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.

ENGLISH

North American and 

European power 

cord plugs shown. 

Depending on your 

country, the plug 

type may vary.

110 NEMA 5-20P 

PLUG (N.A.)

220 NEMA 6-20P 

PLUG (N.A.)

EURO PLUG 

(EUROPE)

Содержание T600

Страница 1: ...T600 ...

Страница 2: ...2 ...

Страница 3: ...Service should only be done by an authorized service technician Installation of parts or accessories not originally intended or compatible with the equipment as sold will void warranty and may impact safety Measured at typical head height the A weighted sound pressure level when the Treadmill is running at 12 Km Hour without load is no greater than 70 dB Noise emission under load is higher than wi...

Страница 4: ...ty and to ensure good treadmill performance the ground on this circuit must be non looped isolated Please refer to NEC article 210 21 and 210 23 Your treadmill is provided with a power cord with a plug listed below and requires the listed outlet Any alterations of this power cord could void all warranties of this product 110 V UNITS Vision 100 125 V 18A treadmills refer to current on regulation de...

Страница 5: ...bricated to aid in assembly and usage Please do not wipe this off If you have difficulty a light application of lithium grease is recommended WARNING There are several areas during the assembly process that special attention must be paid It is very important to follow the assembly instructions correctly and to make sure all parts are firmly tightened If the assembly instructions are not followed c...

Страница 6: ...top of the console cable should be located at the top of the mast Detach and discard lead wire Attach RIGHT CONSOLE MAST 6 to BASE FRAME 2 using 4 BOLTS B and 4 FLAT WASHERS C from the top and bottom NOTE Be careful not to pinch wires while attaching the handlebar Hardware For Step 2 Description Qty E F Bolt Arc Washer 4 4 Open HARDWARE FOR STEP 2 Connect the HEART RATE GRIP WIRE 7 discard the wir...

Страница 7: ...using 2 pre installed screws A Tighten all bolts from steps 1 3 Hardware For Step 4 Description Qty I J K Bolt Spring Washer Flat Washer 4 4 4 Open HARDWARE FOR STEP 4 Connect the CONSOLE CABLES 4 and HEART RATE WIRES 7 to the CONSOLE 11 and carefully tuck the excess cable into the CONSOLE BASE 9 Attach the CONSOLE 11 to the CONSOLE BASE 9 using 4 BOLTS I and 4 SPRING WASHERS J and 4 FLAT WASHERS ...

Страница 8: ...5 Description Qty L M N Screw Power Cord Power Cord Retaining Plate 1 1 1 Open HARDWARE FOR STEP 5 Install the POWER CORD M to the BASE FRAME 2 Install the POWER CORD RETAINING PLATE N to the BASE FREAME 2 using 1 SCREW L ASSEMBLY COMPLETE ...

Страница 9: ...ows the user to set up programs and control workout 1 NUMBER KEYPAD Used to enter program data during program setup Press to confirm settings Press to clear data not yet entered during the workout setup 2 SPEED INCLINE Use to adjust speed or incline 3 GO Press to begin your workout immediately without having to select a workout program 4 STOP Press to stop your workout Press and hold for 3 seconds...

Страница 10: ...NDOM Random creates a random terrain pattern of hills and valleys that varies with each workout 20 00 Time Weight Elevation HEART RATE TARGET HR Target HR is a higher intensity workout for more fit users emphasizing cardiovascular benefits The user must wear a heart rate chest strip or keep hands on contact heart rate grips continuously The program adjusts the intensity level based on the actual h...

Страница 11: ... 30 9 29 4 46 8 44 2 44 6 42 4 41 8 39 9 38 5 36 7 FAIR 50 40 35 2 33 8 33 8 32 3 30 9 29 5 28 2 26 9 42 5 41 0 41 0 38 9 38 1 36 7 35 2 33 8 POOR 30 20 32 3 30 6 30 5 28 7 28 3 26 5 25 5 24 3 39 5 37 1 37 4 35 4 35 1 33 0 32 3 30 2 VERY POOR 10 5 28 3 25 9 26 5 25 1 25 1 23 5 22 3 21 1 34 5 31 6 32 5 30 9 30 9 28 3 28 0 25 1 1 During the test 2 1 If the STOP key is pressed the instrument will ter...

Страница 12: ... SPEED to scroll through the list of Manager Menu options 2 Press to select a custom setting 3 Use SPEED to change the value of the setting 4 To confirm and save the value of the setting press SETTING SAVED will appear in the INSTRUCTION CENTER To exit the setting without saving press for 5 seconds If no key is pressed the system will resume automatically GETTING STARTED 1 Check to make sure no ob...

Страница 13: ...the maximum time it will reset to 0 automatically P9 START SPEED 0 8 kph 0 5 mph 0 8 kph 0 5 mph 3 kph 1 8 mph kph mph 0 1 Controls the starting speed for all programs minimum speed not affected Displayed in native units miles per hour or kilometers per hour Reverts to default value on unit change P10 PAUSE TIME 60 sec 30 sec 180 sec second 1 This is the maximum time during which a workout can rem...

Страница 14: ...admill should not be located in a garage covered patio near water or outdoors LEVELING THE TREADMILL It is extremely important that the levelers are correctly adjusted for proper operation Turn leveling foot clockwise to lower and counter clockwise to raise treadmill Adjust each side as needed until the treadmill is level An unbalanced unit may cause belt misalignment or other issues Use of a leve...

Страница 15: ... left bolt turn If it is moving to the left tighten the left bolt by turning it clockwise turn and loosen the right turn Repeat Step 3 until the belt remains centered for several minutes 4 Check the tension of the belt The belt should be very snug When a person walks or runs on the belt it should not hesitate or slip If this occurs tighten the belt by turning both bolts clockwise turn Repeat if ne...

Страница 16: ...t dizzy or are short of breath USING THE HEART RATE FUNCTION The heart rate function on this product is not a medical device While heart rate grips can provide a relative estimation of your actual heart rate they should not be relied on when accurate readings are necessary Some people including those in a cardiac rehab program may benefit from using an alternate heart rate monitoring system like a...

Страница 17: ...se any equipment that is damaged and or has worn or broken parts Use only replacement parts supplied by your country s local VISION dealer 2 MAINTAIN LABELS AND NAMEPLATES Do not remove labels for any reason They contain important information If unreadable or missing contact your VISION dealer for a replacement 3 MAINTAIN ALL EQUIPMENT Preventative maintenance is the key to smooth operating equipm...

Страница 18: ... 2019 Johnson Health Tech Rev 2 0 A ENGLISH T600 ...