Date of last revision: 2.06
ENGINEERING
GUIDES
TREADMILL.PREMIERENG.REV2
2
ENGINEERING MODE
The user must hold down
“ELEVATION UP”
and
“SPEED DOWN”
for 5 seconds after powering up the treadmill to
enter the engineering menus. The P6 menu appears with the software version in the message center along with the
model number. Press
“STOP”
to exit P6. The user has 6 engineering modes to choose from. The
“SPEED”
and
“ELEVATION”
keys scroll through the modes, while
“SELECT”
chooses the mode. HOLDING the
“SELECT”
button
saves information and the
“STOP”
button goes back to the previous screen.
Display
Engineering Mode
Configure Mode
Edits variables stored in the NOVRAM. Speed and Incline variables can be edited
in this mode.
Display Test Mode
Tests displays and keyboard
Burn In Mode
Runs continuous program
Auto-Calibration Mode
Calibrates both speed and elevation
Speed Sensor Test Mode
Tests speed sensor functionality
RS232 Test Mode
RS232 communication circuit
Exit
Exit engineering mode
ENG1: EDIT VARIABLES MODE
The display shows the P address. To choose the P address press
“SELECT”
.
To clear P9 total time press and hold
“START”
for 3 seconds
To clear P10 total distance press and hold
“START”
for 3 seconds
To clear P19, P20, and P21 time from last maintenance press and hold
“START”
for 3 seconds
T9200/T9250/T9450 VARIABLES
Address
Description
Default Value
Min.Value
MaxValue
P0
Minimum Speed
N/A
310
600
SP1
Speed Check 2
N/A
700
1100
P1
1/2 max
N/A
1400
2100
SP2
Speed Check 4
N/A
2000
3000
P2
Max speed
N/A
3200
4500
P3
LED Brightness
3
0
9
P4
Minimum Elevation
N/A
30
300
P5 Max
Elevation
N/A
650
900
P6
Model and Units
N/A
N/A
N/A
P7
Max Time
99
15
99
P8
Default Weight
150
80
400
P9
Accumulated Time
N/A
N/A
N/A
P10
Accumulated Distance
N/A
N/A
N/A
P11
Belt Thickness (depends on the model)
13
44
P12
Roller Diameter
60
60
60
P13
Elevation motor
1
P14
Pause Time
5:00
:20
10:00
P15
Default Time
30
1
99
P16
Default Age
40
5
120
P17
Elevation Errors (turn on/ off)
1
N/A
N/A
Premier Upper Board: Engineering Guide