background image

SLE-150-B460-P-SL

Scope of Delivery and Accessories

3 SCOPE OF DELIVERY AND ACCESSORIES

Power supply and communication cables are required to operate the device.

Because of the many possible configurations, the cables are listed in the

accessories rather than included in the scope of delivery.

3.1 Scope of Delivery

Designation

Quantity

Device SLE-150-B460-P-SL

1 x

Instructions for Use SLE-150-B460-P-SL

1 x

3.2 Accessories

vicolux smart light lighting controller

Designation

Description

Order no.

DLC-3005

Digital lighting controller, wall

mounting, continuous operation 4.8 A,

flash operation 18 A

1-30-202

DLC-3005-R

Digital lighting controller, rail mounting,

continuous operation 4.8 A, flash

operation 18 A

1-30-209

Connection cable lighting (M8, 4-pin) to DLC

Designation

Description

Order no.

Cable M8-4pin to PTSM -

0.15 m

1-30-208

Cable M8-4pin to PTSM -

1.0 m

1-30-211

Cable M8-4pol to PTSM -

2.0 m

1-30-212

Cable M8-4pol to PTSM -

3.0 m

to connect the lighting to DLC3005;

M8-Socket, 4-pin to PTSM 0.5/4-P-2.5

1-30-213

© Vision & Control GmbH 2021

999.995.377.10-en-1.3

11

Содержание SLE-150-B460-P-SL

Страница 1: ...N CONTROL Instructions for Use SLE 150 B460 P SL Compact spot light Luminous colour Blue 460 nm Instructions for Use SLE 150 B460 P SL Compact spot light Luminous colour Blue 460 nm 999 995 377 10 en...

Страница 2: ...this document on to third parties reproduce and communicate its contents in as far as this has not been expressly authorized Offenders will be liable for damages All rights are reserved with respect...

Страница 3: ...on Description SLE Compact spot light Attachment optics with condenser lens High energy efficiency 150 Luminous field diameter in mm at 200 mm Working distance B460 Luminous colour Blue 460 nm P Power...

Страница 4: ...Notices on the device 15 5 Technical Data 16 5 1 General Parameters 16 5 2 Electrical Parameters 17 5 3 Photometric Parameters 18 5 4 Conditions for Operation Storage and Transport 19 5 5 Technical Dr...

Страница 5: ...SLE 150 B460 P SL Table of Contents 8 1 Maintenance 28 8 2 Service 29 9 Disposal 30 10 EU Declaration of Conformity 31 Vision Control GmbH 2021 999 995 377 10 en 1 3 5...

Страница 6: ...future reference 1 1 Intended Use The device is intended exclusively for use as a lighting element for industrial image processing in automation technology The device is not suitable for use in potent...

Страница 7: ...ns of use Using spare parts which are not original parts from the manufacturer Using incompatible accessory components Improper maintenance and repair works Unauthorised modifications to the device 1...

Страница 8: ...al and rejects any warranty derived therefrom Within the bounds of the legal requirements the manufacturer shall only be responsible for the technical safety characteristics of the device if the maint...

Страница 9: ...s of the danger These measures must be taken DANGER Indicates an imminent danger with high risk resulting in severe injuries or death if not avoided WARNING Indicates a hazardous situation with medium...

Страница 10: ...ons are referred to separately at the relevant points in this manual WARNING Photochemical damage of the retina and retinal burn due to blue light Exposure can be harmful to the eyes In case of operat...

Страница 11: ...x smart light lighting controller Designation Description Order no DLC 3005 Digital lighting controller wall mounting continuous operation 4 8 A flash operation 18 A 1 30 202 DLC 3005 R Digital lighti...

Страница 12: ...operating voltage I O port and lighting without cable 1 x PTSM 0 5 2 P 2 5 1 x PTSM 0 5 7 P 2 5 1 x PTSM 0 5 4 P 2 5 1 30 206 Connection cable DLC PC Designation Description Order no USB cable Type A...

Страница 13: ...pen cable end with ferrules 4 x 0 25 mm 4A 60V PUR IP67 angled plug 1 11 606 Connection cable M8 4 pin straight plug 5A 30V Designation Description Order no Connection cable M8 4pin 1m 1 11 611 Connec...

Страница 14: ...ce Views 1 4 4 2 3 4 4 5 1 4 4 6 4 4 5 Image 1 Device view 1 Casing 2 Light emitting surface 3 Filter thread M28x0 5 depth 5 mm 4 Mounting hole M3x0 5 depth 4 5 mm 5 Mounting hole 4 2 through bore 6 C...

Страница 15: ...ructions are provided on the device Made in Germany www vision control com SLX XXX XXXX P SL 2 1 4 3 1 Notes on power supply 2 Device designation as DataMatrix code 3 Device designation as plain text...

Страница 16: ...otection IP IP 50 Safety class Class III safety extra low voltage SELV Risk group DIN EN 62471 Continuous operation Risk group 2 Flash mode Risk group 2 Overheat protection TMAX 1 80 C 1 The LED overh...

Страница 17: ...meters The LED overheating protection is not guaranteed Parameter Min Nom 1 Max Continuous operation LED current ILED 1 A Forward voltage ULED at ILED Max 2 9 V Power consumption Ptot 2 9 W Flash mode...

Страница 18: ...65 nm Spectral bandwidth 27 nm Luminous efficacy of radiation 51 0 lm W Continuous operation Irradiance 1 30 W m2 Illuminance 1 1 540 lx Radiance 2 188 7 kW m2sr Luminance 2 9 7 Mcd m2 Flash mode Irra...

Страница 19: ...e the specified ambient conditions when transporting and storing the device For accessories connected devices and components observe the specific information in the associated instructions for use Amb...

Страница 20: ...2 3 4 5 1 2 3 4 5 A A B B C C D D 32 30 8 5 10 11 5 5 75 2 x M3 depth 4 5 mm on both sides 8 5 10 M8 connector 10 11 5 75 2 x M3 depth 4 5 mm 10 11 54 32 light emitting surface 26 mm M28x0 5 depth 4...

Страница 21: ...energised state 6 1 Unpacking 1 Lift the cardboard together with the device out of the carton 2 Fold out the tucked in sides on the bottom of the cardboard The film loosens and forms an insertion poc...

Страница 22: ...the Device The following bores can be used for assembly 1 1 1 1 2 1 1 1 1 2 Image 4 Mounting holes 1 6 x M3x0 5 tapped hole maximum screwed in depth 4 5 mm 2 2 x 4 2 mounting hole through bore 22 999...

Страница 23: ...disconnecting The vicolux smart light lighting controller is not hot plug capable Connect or disconnect lights during operation may destroy the lights Connect or disconnect lights only if the lightin...

Страница 24: ...ut 2 1 WH white BD Data Channel for vicolux smart light modules 3 BU blue ILED LED cathode negative current input 4 1 BK black BG Data Channel for vicolux smart light modules 1 Only use in conjunction...

Страница 25: ...tective goggles If you have a known history of epilepsy do not work or stay in areas where there are flashing lights or stroboscopes CAUTION Impairment of eye sight due to dazzling Do not look during...

Страница 26: ...lux smart light lighting controller NOTICE Damage caused by incorrect connecting and disconnecting The vicolux smart light lighting controller is not hot plug capable Connect or disconnect lights duri...

Страница 27: ...es Continuous operation Apply a constant current ILED to the lighting Flash operation Apply current pulses ILED to the lighting Observe the specified parameters see Electrical Parameters page 17 Visio...

Страница 28: ...e specified cleaning sequence Never use dry cloths for cleaning This allows dust and other contaminants to be rubbed into the lens surface thereby damaging it 1 Remove non adherent dusts with a blower...

Страница 29: ...lad to be of service Monday to Thursday 8 00 to 17 00 and Friday 8 00 to 15 00 Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Phone 49 0 3681 7974 0 www vision control com Defective device...

Страница 30: ...eparately and sent to environmentally compatible recycling Disposal including that of individual components must also always be in a way that does not harm the environment which means it must be done...

Страница 31: ...al environments DIN EN IEC 61000 6 4 2020 09 Electromagnetic compatibility EMC Emission standard for industrial environments DIN EN 61000 4 2 2009 12 Electromagnetic compatibility EMC Testing and meas...

Страница 32: ...Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Telephone 49 0 3681 7974 0 Telefax 49 0 3681 7974 33 Vision Control GmbH...

Отзывы: