Vishay TSSP57038H Скачать руководство пользователя страница 6

TSSP57038H

www.vishay.com

Vishay Semiconductors

  

 

Rev. 1.3, 10-Apr-2019

6

Document Number: 82798

THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT

ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT 

www.vishay.com/doc?91000

ASSEMBLY INSTRUCTIONS

Reflow Soldering

• Reflow soldering must be done within 168 h while stored

 

under a max. temperature of 30 °C, 60 % RH after 
opening the dry pack envelope

• Set the furnace temperatures for pre-heating and heating

 

in accordance with the reflow temperature profile as

 

shown in the diagram. Exercise extreme care to keep the

 

maximum temperature below 260 °C. The temperature

 

shown in the profile means the temperature at the device

 

surface. Since there is a temperature difference between

 

the component and the circuit board, it should be verified

 

that the temperature of the device is accurately being

 

measured

• Handling after reflow should be done only after the work

 

surface has been cooled off

Manual Soldering

• Use a soldering iron of 25 W or less. Adjust the

 

temperature of the soldering iron below 300 °C

• Finish soldering within 3 s

• Handle products only after the temperature has cooled off

 

 

 

 

 

 

 

VISHAY LEAD (Pb)-FREE REFLOW SOLDER PROFILE

Note

(1)

MOQ: minimum order quantity

ORDERING INFORMATION

ORDERING CODE

PACKAGING

VOLUME 

(1)

REMARKS

TSSP57038HTT1

Tape and reel

MOQ: 1500 pcs

3.95 mm x 3.95 mm x 0.75 mm

TSSP57038HTT2

MOQ: 5000 pcs

max. 120 s

max. 100 s

max. 20 s

Max. ramp up 3 °C/s

max. 260 °C

10

100

1000

10000

0

50

100

250

300

0

300

Axis Title

2nd l

ine

Temperature (°C)

Time (s)

250

200

150

100

50

200

150

245 °C

217 °C

240 °C

255 °C

Max. ramp down 6 °C/s

Max. 2 cycles allowed

19800

Содержание TSSP57038H

Страница 1: ... Up to 2 m for presence sensing Uses modulated bursts at 38 kHz PIN diode and sensor IC in one package Low supply current External metal shield Visible light is suppressed by IR filter Insensitive to supply voltage ripple and noise Supply voltage 2 5 V to 5 5 V Material categorization for definitions of compliance please see www vishay com doc 99912 DESCRIPTION The TSSP57038H is a compact infrared...

Страница 2: ...velope signal Out to μC ABSOLUTE MAXIMUM RATINGS PARAMETER TEST CONDITION SYMBOL VALUE UNIT Supply voltage VS 0 3 to 6 V Supply current IS 5 mA Output voltage VO 0 3 to VS 0 3 V Output current IO 5 mA Junction temperature Tj 100 C Storage temperature range Tstg 25 to 85 C Operating temperature range Tamb 25 to 85 C Power consumption Tamb 85 C Ptot 10 mW ELECTRICAL AND OPTICAL CHARACTERISTICS Tamb ...

Страница 3: ... Signal IR diode TSAL6200 IF 0 4 A 30 pulses f f0 t 10 ms Output Signal td 1 tpo 2 1 7 f0 td 15 f0 2 tpi 5 f0 tpo tpi 6 f0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 1 10 100 1000 10 000 100 000 t po Output Pulse Width ms Ee Irradiance mW m2 Output pulse width Input burst length λ 950 nm optical test signal Fig 1 Ee t VO VOH VOL t 600 µs 600 µs t 60 ms ton toff 94 8134 Optical Test Signal Output Sign...

Страница 4: ...benefit from the lower gain of these sensors because they are less sensitive to stray signal from the emitter simplifying the mechanical design Example for a sensor hardware There should be no common window in front of the emitter and detector in order to avoid crosstalk via guided light through the window 0 2 0 4 0 6 0 8 1 0 1 2 1 4 1 6 1 8 2 0 2 3 4 5 E e min Sensitivity mW m 2 VS Supply Voltage...

Страница 5: ... GND GND GND 0 75 0 05 4 x 0 75 3 0 35 0 05 8 x 1 5 3 0 3 0 3 0 3 0 7 1 7 3 25 Proposed pad layout from component side dim for reference only 4 3 4 3 0 35 0 8 2 75 4 x 0 75 3 3 x technical drawings according to DIN specifications All dimensions in mm Not indicated tolerances 0 1 Drawing No 6 550 5316 01 4 Issue 2 12 02 14 3 x 0 45 1 2 1 2 3 4 5 8 7 6 Marking area 0 4 Pin 1 identification 0 475 All...

Страница 6: ... there is a temperature difference between the component and the circuit board it should be verified that the temperature of the device is accurately being measured Handling after reflow should be done only after the work surface has been cooled off Manual Soldering Use a soldering iron of 25 W or less Adjust the temperature of the soldering iron below 300 C Finish soldering within 3 s Handle prod...

Страница 7: ...IONS in millimeters Reel size Y TT1 Ø 180 2 1500 pcs Unreel direction X Tape position coming out from reel 2 0 5 Ø 13 0 2 Ø 21 0 8 Label posted here Ø Y Ø 60 min 18 4 max 12 4 Parts mounted Empty leader 400 mm min 100 mm min with cover tape Direction of pulling out Empty trailer 200 mm min X 2 1 8 2 4 Ø 1 5 1 75 0 3 5 5 12 Technical drawings according to DIN specifications Drawing No 9 700 5380 01...

Страница 8: ...e absorption The following conditions should be observed if dry boxes are not available Storage temperature 10 C to 30 C Storage humidity 60 RH max After more than 168 h under these conditions moisture content will be too high for reflow soldering In case of moisture absorption the devices will recover to the former condition by drying under the following condition 192 h at 40 C 5 C 0 C and 5 RH d...

Страница 9: ...ecific data BAR CODE PRODUCT LABEL example 1 Calculated shelf life in sealed bag 12 months at 40 C and 90 relative humidity RH 3 After bag is opened devices that will be subjected to reflow solder or other high temperature process must be 4 Devices require bake before mounting if a Humidity Indicator Card reads 10 for level 2a 5a devices or 60 for level 2 devices when read at 23 5 C b 3a or 3b are...

Страница 10: ...s are not binding statements about the suitability of products for a particular application It is the customer s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application Parameters provided in datasheets and or specifications may vary in different applications and performance may vary over time A...

Отзывы: