Control Systems

  

DRY PACKING

The reel is packed in an anti-humidity bag to protect the
devices from absorbing moisture during transportation and
storage.

FINAL PACKING

The sealed reel is packed into a cardboard box. A secondary
cardboard box is used for shipping purposes.

RECOMMENDED METHOD OF STORAGE

Dry box storage is recommended as soon as the aluminum
bag has been opened to prevent moisture absorption. The
following conditions should be observed, if dry boxes are
not available:

• Storage temperature 10 °C to 30 °C

• Storage humidity 

 60 % RH max.

After more than 72 h under these conditions moisture
content will be too high for reflow soldering.
In case of moisture absorption, the devices will recover to
the former condition by drying under the following condition:
192 h at 40 °C + 5 °C/- 0 °C and < 5 % RH (dry air/nitrogen)
or 
96 h at 60 °C + 5 °C and < 5 % RH for all device containers
or 
24 h at 125 °C + 5 °C not suitable for reel or tubes.
An EIA JEDEC standard JESD22-A112 level 4 label is
included on all dry bags.

VISHAY SEMICONDUCTOR GmbH STANDARD BAR CODE PRODUCT LABEL

 (finished goods)

PLAIN WRITTING

ABBREVIATION

LENGTH

Item-description

-

18

Item-number

INO

8

Selection-code

SEL

3

LOT-/serial-number

BATCH

10

Data-code

COD

3 (YWW)

Plant-code

PTC

2

Quantity

QTY

8

Accepted by

ACC

-

Packed by

PCK

-

Mixed code indicator

MIXED CODE

-

Origin

Company logo

LONG BAR CODE TOP

TYPE

LENGTH

Item-number

N

8

Plant-code

N

2

Sequence-number

X

3

Quantity

N

8

Total length

-

21

SHORT BAR CODE BOTTOM

TYPE

LENGTH

Selection-code

X

3

Data-code

N

3

Batch-number

X

10

Filter

-

1

Total length

-

17

Aluminum bag

Label 

Reel 

15973 

Содержание TSOP351 Series

Страница 1: ... IR remote control data formats The TSOP353 is optimized to better suppress spurious pulses from energy saving lamps The TSOP355 has an excellent noise suppression It is immune to dimmed LCD backlighting and any fluorescent lamps AGC3 and AGC5 may also suppress some data signals in case of continuous transmission This component has not been qualified according to automotive specifications BLOCK DI...

Страница 2: ... 100 C Operating temperature range Tamb 30 to 85 C Power consumption Tamb 85 C Ptot 10 mW ELECTRICAL AND OPTICAL CHARACTERISTICS Tamb 25 C unless otherwise specified PARAMETER TEST CONDITION SYMBOL MIN TYP MAX UNIT Supply current pin 3 Ev 0 VS 3 3 V ISD 0 27 0 35 0 45 mA Ev 40 klx sunlight ISH 0 45 mA Supply voltage VS 2 5 5 5 V Transmission distance Ev 0 test signal see fig 1 IR diode TSAL6200 IF...

Страница 3: ...Output Pulse Width ms 20759 λ 950 nm Optical Test Signal Fig 3 Ton Toff 0 0 0 2 0 4 0 6 0 8 1 0 1 2 0 7 0 9 1 1 1 3 f f0 Relative Frequency 16925 f f0 5 Δ f 3 dB f0 10 E E Rel Responsivity e min e 0 0 5 1 1 5 2 2 5 3 3 5 4 0 01 0 1 1 10 100 Ee Ambient DC Irradiance W m2 E e min Threshold Irradiance mW m 2 Correlation with Ambient Light Sources 10 W m2 1 4 kLx Std illum A T 2855 K 10 W m2 8 2 kLx D...

Страница 4: ... 60 80 100 120 Burst Length number of cycles burst Max Envelope Duty Cycle 22180 3 f 38 kHz Ee 2 mW m TSOP355 TSOP353 TSOP351 0 0 05 0 1 0 15 0 2 0 25 0 3 30 10 10 30 50 70 90 Tamb Ambient Temperature C E e min Threshold Irradiance mW m 2 20755 0 0 0 2 0 4 0 6 0 8 1 0 1 2 750 850 950 1050 1150 λ Wavelength nm 16919 S Relative Spectral Sensitivity λ rel 16801 0 4 0 2 0 0 2 0 4 0 6 0 6 0 9 0 30 10 2...

Страница 5: ...odulation Note For data formats with long bursts more than 10 carrier cycles please see the datasheet for TSOP352 TSOP354 0 10 15 20 Time ms 16920 IR Signal IR Signal from Fluorescent Lamp with Low Modulation 5 0 10 15 20 Time ms 16921 IR Signal IR Signal from Fluorescent Lamp with High Modulation 5 TSOP351 TSOP353 TSOP355 Minimum burst length 6 cycles burst 6 cycles burst 6 cycles burst After eac...

Страница 6: ... at the device surface Since there is a temperature difference between the component and the circuit board it should be verified that the temperature of the device is accurately being measured Handling after reflow should be done only after the work surface has been cooled off Manual Soldering Use a soldering iron of 25 W or less Adjust the temperature of the soldering iron below 300 C Finish sold...

Страница 7: ...trol Systems Vishay Semiconductors VISHAY LEAD Pb FREE REFLOW SOLDER PROFILE TAPING VERSION TSOP TT Dimensions in millimeters 0 50 100 150 200 250 300 0 50 100 150 200 250 300 t s T C 255 C 240 C 245 C max 260 C max 120 s max 100 s 217 C max 20 s max Ramp Up 3 C s max Ramp Down 6 C s max 2 cycles allowed 19800 16584 ...

Страница 8: ...ww vishay com Document Number 81780 8 Rev 1 5 09 Jul 10 TSOP351 TSOP353 TSOP355 Vishay Semiconductors IR Receiver Modules for Remote Control Systems TAPING VERSION TSOP TR Dimensions in millimeters 16585 ...

Страница 9: ...mm min 165 to 180 peel angle LABEL Standard bar code labels for finished goods The standard bar code labels are product labels and used for identification of goods The finished goods are packed in final packing area The standard packing units are labeled with standard bar code labels before transported as finished goods to warehouses The labels are on each packing unit and contain Vishay Semicondu...

Страница 10: ...or reflow soldering In case of moisture absorption the devices will recover to the former condition by drying under the following condition 192 h at 40 C 5 C 0 C and 5 RH dry air nitrogen or 96 h at 60 C 5 C and 5 RH for all device containers or 24 h at 125 C 5 C not suitable for reel or tubes An EIA JEDEC standard JESD22 A112 level 4 label is included on all dry bags VISHAY SEMICONDUCTOR GmbH STA...

Страница 11: ... procedures should be followed to prevent ESD damage to the devices especially when they are removed from the antistatic shielding bag Electro static sensitive devices warning labels are on the packaging VISHAY SEMICONDUCTORS STANDARD BAR CODE LABELS The Vishay Semiconductors standard bar code labels are printed at final packing areas The labels are on each packing unit and contain Vishay Semicond...

Страница 12: ...otherwise modify Vishay s terms and conditions of purchase including but not limited to the warranty expressed therein which apply to these products No license express or implied by estoppel or otherwise to any intellectual property rights is granted by this document or by any conduct of Vishay The products shown herein are not designed for use in medical life saving or life sustaining application...

Отзывы: