53
Viscount
Physis Organs
Reference Manual
9.13 AUTOMATIC RESIZE OF EXTERNAL ROUTERS (EXTERNAL OUT
RESIZE function)
As already shown in par. 9.10, with External Routers, each stop can be channelled to one or more
PROGRAMMABLE rear Outputs; connecting more outputs after the stop channelling has been programmed
may affect some output related features, so that some outputs may not work as intended. The EXTERNAL
OUT RESIZE function sets up the output configuration (concerning the windchest size but not its type)
according to the amount of outputs in use.
To recall the function, selecte the EXT. OUT RESIZE field under the SET-UP menu.
The system will warn you that the external panning of the stops will be modified automatically (according to
the outputs in use). Press [EXIT] to abort and go back to the SET-UP menu. Press [ENTER] to continue:
the following screen will show:
The
CURRENT MAIN OUTS USED
parameter points out the amount of outputs currently used by the
External Routers, as set in the EXTERNAL OUT ROUTER function.
Instead, the
RESIZE TO
parameter must be set to the current amount of connected outputs. Press [EXIT]
to cancel the new configuration, or [ENTER] to confirm it.
The repositioning takes place through several adjustments, so as to use the outputs as already configured
before. However, some routers might be placed differently from what you intended. Therefore, at the end of
the procedure, the system will advice to check again the settings through the EXTERNAL OUT ROUTER
function.