4.1

Informal safety measures

» The operating and maintenance instructions should always be kept at the location 

where the control system is in use.

» General and local regulations on health, safety and environmental protection must also 

be provided and complied with.

4.2

Use of symbols

The following symbols are used in these instructions:

4.3

Correct use, warranty

The control system is designed for controlling our dispensers in non explosion-protected 

environments.

Any
» modifications and additions,
» use of non-genuine spare parts,  
» repairs by persons or organisations not authorised by the manufacturer

that are made without the express, written consent of the manufacturer will render the 

warranty void and result in the loss of any right to make a claim under the warranty.

No liability can be accepted for damage caused by failure to observe the operating and 

maintenance instructions.

4.4

Qualifications of the operators and maintenance personnel

The operating organisation is responsible for ensuring that the operators and 

maintenance personnel are suitably qualified. The operating and maintenance 

instructions must have been read and understood. The relevant technical rules and safety 

regulations must be complied with.

Text in 

italics

Names of keys/buttons, connectors, chapters, screen displays, proper 

names and input boxes

1

Legend number in an illustration
Warning note. Failure to observe these notes may result in injury and 

damage to the control system.
Reference to technical information about operation and / or about 

preventing damage.

Содержание preeflow plug'n'dose AM

Страница 1: ...Dosing system Speed Control plug n dose AM Operating and maintenance instructions Translation of the German original operating manual ...

Страница 2: ...Printed 22 1 16 ...

Страница 3: ...ations of the operators and maintenance personnel 5 4 5 Organisational measures 6 4 6 Preparing to operate visual inspection 6 4 7 Preventing damage to the dispenser motor 6 5 Operation 7 5 1 Displays and controls connections 7 5 2 Cable assignment connector 1 7 5 3 Important for signal definition 8 5 4 Starting up 8 5 5 Shutting down 9 5 6 Operation 9 6 Troubleshooting Maintenance 9 7 Specificati...

Страница 4: ...tested for precision operation with our dispensers We would appreciate your assistance in our efforts to maintain the highest possible quality standards Please send us any suggestions you may have on ways that we may further improve our products 2 Function description The plug n dose AM control system controls the dispenser according to the signals that are generated by the master controller This ...

Страница 5: ...express written consent of the manufacturer will render the warranty void and result in the loss of any right to make a claim under the warranty No liability can be accepted for damage caused by failure to observe the operating and maintenance instructions 4 4 Qualifications of the operators and maintenance personnel The operating organisation is responsible for ensuring that the operators and mai...

Страница 6: ...tions for the dispenser s that are connected to the control system must be complied with 4 6 Preparing to operate visual inspection The control system must be visually examined each day before the start of work and before all shift changes If there is any doubt as to the system s readiness for operation it must be shut down immediately and inspected by a specialist before operation resumes 4 7 Pre...

Страница 7: ...ED Displays the operating modes ON ready for operation OFF dosing suck back in operation Flashing fault 1 Connector 1 Control signal see 5 2 3 Connector 3 Dispenser PIN Colour Function description 1 white Start dosing 1 24 V 1 Dispenser motor runs medium is delivered 2 brown Start suck back 2 24 V 2 Dispenser motor runs in reverse medium is sucked back in to avoid dripping 3 pink Fault interval 0 ...

Страница 8: ...enser D Connect 1 the cable of the master controller1 B Notice The control system is only ready for operation when the dispenser is connected Fill the dispenser with medium as directed in its operating and maintenance instructions Caution The dispenser lead connector 3 may only be connected and disconnected when the power supply is isolated The electronics in the drive motor could be damaged if th...

Страница 9: ...ee Do not use any aggressive solvents or detergents to clean the unit use a damp cloth only Isolate from the power supply before cleaning 7 Specifications Fault Possible cause Action control system does not operate LED flashes fault signal is output PIN 3 Overcurrent shutdown Clean the dispenser if necessary replace stator See the operating instructions for the dispenser Faulty motor Dimensions h ...

Страница 10: ...ousehold waste They must be taken to the collection points provided for this purpose 2002 96 EC WEEE EC Directive on waste electrical and electronic equipment This unit complies with RoHS requirements ViscoTec Pumpen und Dosiertechnik GmbH Amperstraße 13 D 84513Töging Product description Function Dosing system with dispenser Model plug n dose AM with dispenser eco PEN300 450 600 700 Harmonised sta...

Страница 11: ...plug n dose AM Operating and maintenance instructions Copyright Version 1 3 11 11 Notizen This is the last page in this document ...

Страница 12: ...info preeflow com www preeflow com ...

Отзывы: