(e.g. open cartridge, dispenser fixed in place and supply of the material under pressure)
Tip:
Alternatively, the air can also be extracted from the pump area with the syringe (9)
included in the scope of supply.
Turn the bleed screw (23) 180 degrees so
that the bleed hole (8) is in the position
shown (direction of the drive unit).
Pressurise the material.
Feed the material until it escapes from the
bleed hole (8) without bubbles.
Release (remove) the inlet pressure on
the material and wait until no more
material comes out of the bleed hole (8).
Close the bleed screw (23) again.
Remove any material which has escaped.
Pressurise the material.
Connect the drive unit to the power supply
and run slowly until the material escapes
from the outlet nozzle (attached Luer-Lock
needle) without bubbles.