22 / 36
4.4
Switching off, ending dosing process
If the dosing process for a 2-component system has to be terminated, the outlet openings
(A and B) have to be cleaned.
* Recommendation: OKS-469, OKS, www.oks-germany.com
Place dosing control unit in manual operation.
Release mixing capsule from mixing head and
dispose of in accordance with the material
manufacturer's regulations. The mixing capsule
must not be cleaned and reused.
Clean connection thread for mixing capsule
and holes (outlet openings). Ensure that the two
components are not mixed.
Hold the mixing head downwards and purge
bores (A and B) individually. Catch any material
leakage and clean the mixing head again.
Ensure that the two components are not mixed.
Use separate cloths.
Switch off material supply to the dosing pump.
Switch off dosing control unit and secure it
against unauthorised restarting.
Protect the connection thread and outlets against
drying out and soiling, where necessary (e.g. with
a cap and/or by applying lubricant* on the
relevant areas). Follow the material
manufacturer's instructions).
Fig. 13
A
B