5.8.1
Dosing programs
Quantity program
The
quantity program
is used to give out a fixed and defined quantity of medium.
Depending on the dispenser and the medium used, it is possible to set very small
amounts per dosing. The dosing time is determined by the volume flow. The dosing
operation can be broken off at any time until the set time has expired (
STOP
key).
Note:
The controller automatically sets the theoretical dosing amount at the connected
dispenser.
Maximum flow quantity that can be set:
start / stop program
The
start / stop program
is used when the dispenser is set to convey the medium for the
relevant individual period by the operator (or an external controller). The amount that is
dispensed can be defined. The dosing quantity is determined by the volume flow.
Time program
The
time program
is used if the dosing is to be done for a set period. This is triggered by
the operator (or an external controller). The amount that is dispensed can be defined. The
dosing operation can be broken off at any time until the set time has expired (
STOP
key).
The maximum dosing time that can be set is 99.99 seconds.
5.8.2
Operating modes
Dosing manually
In the three dosing programs the dosing is initiated by pressing the
START
key. The
quantity programs
and the
time program
end the dosing by itself once the set values have
been reached or at the end of the set dosing time.
In the
start / stop program
the dosing is ended by pressing the STOP key.
Dosing with the foot switch
The dosing system reacts to the pressing of the foot switch as follows:
In the quantity and time programs the dosing can be stopped by pressing the
STOP
key
before the specified values have been reached (EMERGENCY STOP). A set pause and
a return flow are carried out as well.
eco-PEN300 0,1 ml eco-PEN450 11 ml eco-PEN600 34 ml eco-PEN700 100 ml
Dosing program
Press the foot switch
... and release it again
Quantity program
Quantity program ends
Start / stop program
Dosing on
Dosing off
Time program
Time program ends