IPI-4 Converter – Installation Guide
Page 5 of 6
D-301285_V6.0
Configuring AXSalert for Remote Management
AXSalert (all versions) can be configured to simultaneously
monitor and manage the access control hardware on multiple
AXS-100 loops over a local area network (LAN) or a wide area
network (WAN) running TCP/IP using separate IP Ports
.
Each defined IP Port enables the AXSalert server machine
(using a designated IP port) to bi-directionally communicate
with one Master AXS-100/200 controller via the IPI-4 adapter
.
1.
Ensure that the Master controller (including the IPI-4) is
powered up and wired correctly to the AXSalert host
machine via the LAN/WAN network.
2.
Launch AXSalert; the main AXSalert window appears.
3.
Access the Setup menu and click the Options command;
by default the Controller tab of the Setup window appears.
4.
Access the Communication tab; press Add Port and
enable the IP Port option.
Should communication error boxes appear at anytime during
this procedure, press OK each time a message appears box in
order to bypass them.
5.
In the field located to the right of the IP port option, enter
both the IP Address plus as well as the number of the IP
Port (default=10001). The IP address and
IP port number
MUST be separated by colon punctuation mark (“:”) as
shown in the example here: 62.0.18.235:300
.
Specifications & Order Details
Electrical Specifications
Input Voltage
5 VDC (+/-5%) via AXS-100 controller
Serial
Interface
RS-232 – 6 pin rigid Interface
Network
Interface
Female RJ45, 10Base-T or 100base-
TX (auto-sensing)
Compatibility
Ethernet: Version 2.0/IEEE 802.3
Data Rate
115.2 Kbps
Supported
Protocols
ARP, UDP/IP, TCP/IP, Telnet, ICMP,
SNMP, DHCP, BOOTP, TFTP, Auto IP
and HTPP
Visual Indicators
Amber LED: Link, Green LED: Activity
General Specifications
Construction
PCB board (no enclosure)
Dimensions
(L x W x D)
59.0 x 39.0 x 1.7mm
(2.32 x 1.54 x 0.67 inches)
Weight
15 grams (0.53 ounces) approx.
Operating
Temperature
& Humidity
0°C to 80°C (32°F to 176°F)
05% to 90% non-condensing
Storage
Temperature
0°C to 80°C (32°F to 176°F)
Browser-based
Configuration
Lantronix Programming Software
Remote
Management
EIRIS V4.6 or higher and
AXSalert (all versions)
Standards
Compliance
EMI tested and complaint
Warranty
One year limited warranty
(excluding batter)
Ordering Details
IPI-4 Converter
5-100482
IPI-4, Serial Port to Ethernet Adapter
Compatible Controllers
4-6280-4
AXS-100M, 2-door Controller, PCB only
3-6280-0
AXS-100, 2-door Controller, Metal Box, 230
Transformer
3-6280-1
AXS-100, 2-door Controller, Metal Box, 110
Transformer