IMPORTANT SAFETY INSTRUCTION

1.  Upon receipt of device, check for any potential damage and inclusion of all equipment 

required to use device properly. Refer to Device Description for components.

2.  This device is intended for indoor use only.

3. 

Turn device off prior to installation and engaging with power supply.

4. 

Do not obstruct airflow to or from device.

5. 

To move the device, turn the device off and disconnect from power supply.

6.  To avoid electric shock and device damage, plug into an appropriate 110v outlet using the 

power cord provided.

7.  Do not handle device with wet or damp hands.

8.  Do not sit or stand on the device.

9.  Do not submerge the device or expose the device to water.

10. 

Never insert any object or limbs into the device.

11.  Do not stand directly in front of the device when in use.

12.  This device is a hard-mounted unit.  The device should be disconnected from power supply 

before installing, moving, cleaning, fuse replacement and/or mounting.  For hard-mounted, 

device must be secured properly, using approved mounting hardware.

13.  Do not use unapproved tripods, mounting devices, or electric cords to operate or install this 

device.

14.  Do not attempt any maintenance on this device. All maintenance must be performed by a 

technician certified by VentorLux. Tampering may cause harm and void warranty.

15.  This product employs overload protection. A blown fuse indicates an overload or short-

circuit situation. If the device does not turn on, it may indicate a fuse is blown. Replacing a 

fuse is not considered maintenance and may be performed by operator. Prior to changing 

fuse, disconnect the device from power supply and replace the fuse as outlined in Operating 

Instructions. In the event the device continues to short-circuit, discontinue use and contact 

the manufacturer at (706) 992-8382.

16.  Removing dust accumulated on the outside of the device is not considered maintenance 

and may be performed by an operator. Before cleaning, disconnect the device from power 

supply. See Operating Instructions.

17. 

To reduce the risk of fire, electric shock, or injury, turn the unit off and disconnect the unit 

from power supply before moving, cleaning, or changing fuse.

18.  After moving, cleaning, or changing fuse the unit must be reinstalled or remounted as 

previously installed prior to operation.

19.  Do not operate the device with a damaged cord or plug.

20.  Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar 

coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic 

area to avoid a tripping hazard.

21.  This device is not a toy and should not be handled or operated by children.

KEEP THESE INSTRUCTIONS!

READ ALL INSTRUCTIONS BEFORE USING THIS PRODUCT

WARNING: 

 T

o avoid risk of electric shock or fire, disconnect from power supply prior to installing, 

moving, cleaning, or changing fuse.

CAUTION: 

 M

aintenance of this device must be performed by a certified technician of VentorLux

This device contains UV lights which can be harmful to skin and eyes if misuse or tampering of

product occurs. This product has tested safe for use in occupied spaces for humans, pets, plants,

and food.

Содержание SOULIS X1

Страница 1: ...AIR PURIFICATION SYSTEM SOULIS X1 Summary Read Carefully to Ensure Proper Usage and Operation ...

Страница 2: ...SOULIS X1 OPERATION SAFETY MANUAL ...

Страница 3: ...CATIONS 6 04 INSTALLATION INSTRUCTIONS 8 05 OPERATION 10 06 PRODUCT FEATURES 12 07 MAINTENANCE 14 08 WARRANTY 16 TABLE OF CONTENT SOULIS X1 PROVIDES A SAFE ANSWER TO AIR PURIFICATION KILLING HARMFUL AIRBORNE MICRO ORGANISMS Read all safety warnings and instructions Failure to follow warnings and instructions may result in electric shock fire and or serious injury Do not attempt to tamper with the ...

Страница 4: ...fuse is blown Replacing a fuse is not considered maintenance and may be performed by operator Prior to changing fuse disconnect the device from power supply and replace the fuse as outlined in Operating Instructions In the event the device continues to short circuit discontinue use and contact the manufacturer at 706 992 8382 16 Removing dust accumulated on the outside of the device is not conside...

Страница 5: ......

Страница 6: ... designed to be ceiling wall or floor mounted Each unit comes with a 3 8 threaded rod holding hole in the upper section of the hanging yoke as well as a wall or counter mount stand SOULIS X1 MOUNTING INSTALLATION GUIDE ...

Страница 7: ...n a location that allows for maximum airflow into and out of the unit To engage Soulis connect power cord and click the switch ON I To turn Soulis off click the switch OFF O Cleaning the outside of Soulis is not considered maintenance and may be performed by the operator Use a dry rag to remove dust from the device exterior The device must be disconnected from the power source before cleaning Chan...

Страница 8: ...other micro organisms by cycling air through the device s Photolysis Chamber The air is then exposed to a specific frequency of UVC light causing the Pathogens and other micro organisms to be modified or destroyed The Photolysis chamber ensures no UVC light or Radiation can escape the chamber making it safe to use around people without the use of PPE Personal Protection Equipment Diagram Definitio...

Страница 9: ...ctric shock or injury to persons disconnect Soulis from the power supply before cleaning or changing the fuse Cleaning the outside of Soulis is not considered maintenance and may be performed by the operator See Operating Instruction for details Changing a fuse is not considered maintenance and may be performed by the operator SoulisParticle Filters are required during operation 2 Soulis particle ...

Страница 10: ...Use this unit only in the manner intended by the manufacturer If you have questions contact customer service at 706 992 8382 1 Grasp plug and remove from the receptacle or other outlet device Do not unplug by pulling on cord 2 Open fuse cover in the center 3 Remove fuse carefully from the fuse holder Grab on both ends 4 Risk of fire Replace fuse only with a 5 amp fuse 5 Insert and close fuse cover...

Страница 11: ...Y THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER WARRANTIES AND OBLIGATIONS OF VentorLux OR ITS SUPPLIERS EXPRESS OR IMPLIED VentorLux EXPRESSLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE LIMITATION OF REMEDY Under no circumstances shall VentorLux or any supplier of VentorLux be liable for any loss or damage including but not limited to loss or damage ...

Страница 12: ...nfecting chamber discharging disinfected air providing a pathogen free space Tested 100 safe for occupied spaces Soulis is safe for use in the presence of humans animals plants and food and offers 24 7 proactive disinfection of the air Soulis creates approximately 300 Cubic Feet per Minute CFM of clean air creating pathogen free environments Surrounding air is safely and quickly disinfected greatl...

Страница 13: ......

Страница 14: ......

Страница 15: ...NOTES ...

Отзывы: