Viridian EV EPC E32F21 Скачать руководство пользователя страница 7

Iss 1.3 Aug 2019 

 

EVSE Protocol Controller (EPC) Manual | Viridian EV

 

 7 

 

 

INPUT CURRENT RESISTANCE INFORMATION

 

 

An Input Current (IC) resistance (or equivalent voltage) restricts the current maximum advertised by the EPC. The 
resistor (or voltage) is applied across the IC and 0V terminals. It is recommended to use a resistor of 0.1% 
tolerance & power rating of 63mW or greater.

 

 

 

The IC values are as described below: 

 

 

Max Current

 

IC Resistance (Ohms)

 

IC Equivalent Voltage (V)

 

80A

 

9090

 

4.5045

 

79A

 

8060

 

4.4481

 

78A

 

7320

 

4.3990

 

77A

 

6650

 

4.3464

 

76A

 

6190

 

4.3046

 

75A

 

5620

 

4.2447

 

74A

 

5230

 

4.1974

 

73A

 

4870

 

4.1482

 

72A

 

4530

 

4.0958

 

71A

 

4220

 

4.0421

 

70A

 

4020

 

4.0040

 

69A

 

3740

 

3.9451

 

68A

 

3570

 

3.9059

 

67A

 

3320

 

3.8426

 

66A

 

3160

 

3.7981

 

65A

 

3010

 

3.7531

 

64A

 

2870

 

3.7080

 

63A

 

2670

 

3.6376

 

62A

 

2550

 

3.5915

 

61A

 

2430

 

3.5423

 

60A

 

2320

 

3.4940

 

59A

 

2210

 

3.4424

 

58A

 

2100

 

3.3871

 

57A

 

2050

 

3.3607

 

56A

 

1960

 

3.3108

 

55A

 

1870

 

3.2578

 

54A

 

1780

 

3.2014

 

53A

 

1690

 

3.1413

 

52A

 

1620

 

3.0916

 

51A

 

1580

 

3.0620

 

50A

 

1500

 

3.0000

 

49A

 

1430

 

2.9424

 

48A

 

1370

 

2.8903

 

47A

 

1330

 

2.8541

 

46A

 

1270

 

2.7974

 

45A

 

1210

 

2.7376

 

44A

 

1180

 

2.7064

 

43A

 

1130

 

2.6526

 

Содержание EPC E32F21

Страница 1: ...Iss 1 3 Aug 2019 EVSE Protocol Controller EPC Manual Viridian EV 1 EVSE Protocol Controller EPC Manual http viridianev co uk info viridianev co uk ...

Страница 2: ... for commissioning and using the Viridian EV EPC They are intended for use by electrically skilled persons who commission the device SCOPE OF VALIDITY OF THIS DOCUMENTATION This documentation is valid for all components of the Viridian EV EPC specified in this Manual and describes the delivery state as of Aug 2019 THIS PRODUCT IS BASED ON THE IEC 61851 AND SAE J1772 INTERNATIONAL STANDARDS ...

Страница 3: ...tem installer and plant operator are responsible for the necessary line protection The relay outputs are not fused within the device Without appropriate protection of the relay outputs overloading can cause undesirable heat generation or even fire The relay outputs are to be fused externally by the plant constructor 2 3 REPAIRS Repairs are not permitted Defective devices must be disposed of in com...

Страница 4: ...r 80 2 is either T for tethered versions or F for free cable socket versions 3 indicates the hardware revision e g 32 or 33 AREAS OF APPLICATION USE Controlling the charging procedure of electric vehicles For communication with the electric vehicle according to IEC 61851 or SAE J1772 MOUNTING Mounting onto standard rail according to DIN EN 60715 CONNECTION ELEMENTS Relay contacts for switching the...

Страница 5: ...rging area is required in buildings STATE E Short circuit power supply disconnected from electric vehicle electricity is not available other power supply problem STATE F EVSE is not available other power supply problem SEQUENCE OF CHARGING PROCESS 1 INITIALIZATION After the operating voltage is applied the module carries out initializations and function tests indicated by two LED flashing sequence...

Страница 6: ...fied current must be consistent with the line protection configured for the charging device and the rest of the plant configuration Failure to observe this notice can result in injury to persons or property damage PROXIMITY With free cable installations the charging device detects the maximum current carrying capacity of the connected charging cable via the proximity signal The activated charging ...

Страница 7: ...C Equivalent Voltage V 80A 9090 4 5045 79A 8060 4 4481 78A 7320 4 3990 77A 6650 4 3464 76A 6190 4 3046 75A 5620 4 2447 74A 5230 4 1974 73A 4870 4 1482 72A 4530 4 0958 71A 4220 4 0421 70A 4020 4 0040 69A 3740 3 9451 68A 3570 3 9059 67A 3320 3 8426 66A 3160 3 7981 65A 3010 3 7531 64A 2870 3 7080 63A 2670 3 6376 62A 2550 3 5915 61A 2430 3 5423 60A 2320 3 4940 59A 2210 3 4424 58A 2100 3 3871 57A 2050 ...

Страница 8: ...uivalent Voltage V 42A 1070 2 5845 41A 1050 2 5610 40A 1000 2 5000 39A 959 2 4477 38A 931 2 4107 37A 887 2 3503 36A 845 2 2900 35A 825 2 2603 34A 787 2 2020 33A 750 2 1429 32A 732 2 1132 31A 698 2 0554 30A 665 1 9970 29A 634 1 9400 28A 619 1 9117 27A 590 1 8553 26A 562 1 7990 25A 536 1 7448 24A 511 1 6909 23A 491 1 6465 22A 475 1 6102 21A 453 1 5588 20A 432 1 5084 19A 412 1 4589 18A 392 1 4080 17A...

Страница 9: ...tables LED DESCRIPTION OF OPERATING STATE COLOUR STATUS NOT LIT NOT LIT Device is not active switched off No power supply BLUE FLASHING 1 HZ Device is waiting to be connected to an electric vehicle Status A BLUE STEADY Electric vehicle connected electric vehicle not ready for charg ing Status B GREEN STEADY Charging process active Status C RED STEADY Electric vehicle requires ventilation charging ...

Страница 10: ...l Controller EPC Manual Viridian EV 10 4 MOUNTING 4 1 MOUNTING ONTO STANDARD RAIL 1 Clip the device a vertically onto the horizontal DIN rail b Swing the device downward until the unlocking slider on the DIN rail clicks into place ...

Страница 11: ...g to the respective type of circuit Failure to observe this notice can result in injury to persons or property damage Depending on the device version the Viridian EV EPC charging controller is connected to the EVSE in the following methods 5 1 CONNECTING TERMINALS TERMINAL ASSIGNMENT TETHERED CABLE Tethered means that the charging cable is permanently connected to the EVSE P3 P6 are not present an...

Страница 12: ...Iss 1 3 Aug 2019 EVSE Protocol Controller EPC Manual Viridian EV 12 EPC TERMINAL ASSIGNMENT TETHERED VERSION FREE CABLE VERSION Solenoid Lock Motor Lock ...

Страница 13: ...ge the lock for motorised locks ML MU MOTOR UNLOCK ExxF32 This provides return path for the solenoid circuit OV ExxF33 This provides 12V 300mA for 500 ms to disengage the lock MU HF LOCK FEEDBACK Reads lock feedback for motorised locks NC NOT CONNECTED P1 Relay 1 live from RCBO P2 Relay 1 coil on the contactor P3 Relay 2 live from 32A RCBO P4 Relay 2 coil on the 32A contactor P5 Relay 3 live from ...

Страница 14: ... Manual Viridian EV 14 5 2 230 V AC POWER SUPPLY WIRING EXAMPLE 230 V AC WARNING THE EXTERNAL CONTACT BLOCKS USED MUST BE FLOATING AND SAFELY SEPARATED FROM UNSAFE CIRCUITS Failure to observe this can result in injury to persons or property damage ...

Страница 15: ...nection to the 0V is only a functional ground Failure to observe this notice can result in electric shock or damage to property 5 4 RELAY OUTPUTS We recommend single fusing with 230 400 V 10 kA circuit breakers 1 pin C 2 A T 70 mm SHUTDOWN OF POWER BRANCH According to IEC 61851 a shutdown of the power branch on completion of the charging process within 3 s is required A shutdown of the power branc...

Страница 16: ...juries Disconnect the system and all devices from the power supply before starting work PROCEDURE 1 Disconnect the wiring from all EPC connector terminals 2 Disassemble the device by pulling the locking slider on the back of the device down and swivel the device away from the DIN rail and remove it 3 Install the new device by clipping the top locking guide onto the DIN rail and swinging it down un...

Страница 17: ...Iss 1 3 Aug 2019 EVSE Protocol Controller EPC Manual Viridian EV 17 7 DIMENSIONAL DRAWINGS ...

Отзывы: