background image

Quick Reference Guide

27

Section 7

Quick Reference Guide

General Operation

When the system is operating, one of the following four displays 
will be shown:

  •

“TIME OF DAY/GPM”, “FLOW RATE”, “CAPACITY 
REMAINING” or “DAYS TO A REGEN”. 

  •

Pressing 

NEXT

 will toggle between the three choices.

Manual Regeneration

Note: 

For softeners, if brine tank does not contain salt, fill with 

salt and wait at least two hours before regeneration. If you need 

to initiate a manual regeneration, either immediately, or the 

same night at the pre programmed time, for regeneration 

(typically 2:00 AM), complete the following steps.

1

Press and hold 

REGEN

 until valve motor starts (typically 3 

seconds).

2

Press and release 

REGEN

 (notice that flashing appears).

To Set Time of Day

In the event of a prolonged power outage, time of day flashes, 
indicating that this needs to be reset. All other information will 
be stored in memory no matter how long the power outage.

1

Accessed by pressing 

SET CLOCK

.

2

Adjust hours with 

U

 

and 

V

 buttons, AM/PM toggles at 12.

3

Press 

NEXT

4

Adjust minutes with 

U

 

and 

V

 buttons

5

Press 

NEXT

 to complete and return to normal operation

Bypass

To shut off water to the system, position arrow handles as 
shown in the bypass operation diagram below. If your valve 
doesn’t look like the diagram below, contact your service 
technician for instructions on how to shut off water.

Error

If the display toggles between “ERROR” 
and an error code (i.e. a number), 
call a service technician and report the
error code.

Adjust Hardness, Days Between Regeneration, Time of Regeneration and Alarm Buzzer

For initial set-up or to make adjustments, please complete the following steps

:

Note: 

Hardness display shows “-nA-” if used as a filter. If other displays do not appear, refer to manual.

1

Accessed by pressing 

NEXT

 and 

U

 button simultaneously.

2

Adjust hardness using 

U

 

and 

V

 buttons.

3

Press 

NEXT.

4

Adjust days between regenerations using 

U

 

and 

V

 buttons.

5

Press 

NEXT.

6

Adjust time of regeneration hour with 

U

 

and 

V

 

buttons, “

AM

/

PM

” toggles at 12:00. 

7

Press 

NEXT

.

8

Adjust time of regeneration minutes with 

V

 and 

V

 buttons.

9

Press 

NEXT

 to complete and return to normal operation.

“REGEN  TODAY”  AND  “TIME   OF  

DAY”  WILL   FLASH  ALTERNATELY

  IF  A  

REGENERATION

 IS  EXPECTED  TONIGHT.

NORMAL OPERATION

BYPASS OPERATION

Содержание WS series

Страница 1: ...W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com Model WS Series Owner s Manual...

Страница 2: ...nstalled and operated properly Please study this manual carefully and understand the cautions and notes before installing This manual should be kept for future reference If you have any questions rega...

Страница 3: ...rm control valve repairs or maintenance The 1 full flow bypass valve incorporates four positions including a diagnostic position that allows a service technician to have pressure to test a system whil...

Страница 4: ...ration could cause a siphoning of brine into the building If water is available on the outlet side of the softener or filter it is an indication of water bypassing the system Refer to Figure 4 i e a p...

Страница 5: ...and O ring Avoid getting solder flux primer and solvent cement on any part of the O rings split rings bypass valve or control valve If the building s electrical system is grounded to the plumbing inst...

Страница 6: ...l attention to codes for air gaps and anti siphon devices Note Drain line nut will not be supplied for units having a backwash rate greater than 7 gpm 7 Brine Tank Connection Install the 3 8 O D polye...

Страница 7: ...display Insert the sleeve removal tool at the bottom of the sleeve 1 Press NEXT and simultaneously for 3 seconds 2 Set the amount of hardness in grains per gallon default 20 using the or buttons The...

Страница 8: ...time remaining for that step to be completed The system runs through the steps automatically and will reset itself to provide treated water when the regeneration has been completed 3 2 3 Manual Regen...

Страница 9: ...y should be replaced The battery is a 3 Volt lithium coin cell type 2032 and is readily available at most stores To access battery location remove front cover refer to Section 5 1 3 2 5 Error Message...

Страница 10: ...led in Step 1 press REGEN again and the display will read SOFTENING 240 During a full regeneration this will be a 4 hour period for salt to dissolve Press REGEN again to put the valve into BACKWASH Un...

Страница 11: ...line securely with rigid piping 1 Included with your backwashing filter are two check valves 3 8 John Guest push in type with a screen 1 FPT stainless steel check valve 2 The 3 8 JG valve has a small...

Страница 12: ...liver soft water in this position 3 Softening Position Water in the brine tanks slowly dissolves salt in preparation for Brine Rinse Position During this cycle unit will delivery soft water Factory se...

Страница 13: ...main or regenerant piston Replace main or regenerant piston Valve does not regenerate automatically when REGEN button is pressed Transformer unplugged Connect transformer and PC board power No power a...

Страница 14: ...t Number Quantity 1 Front cover grey WS CV317CC 01 1 2 Motor CV3107 1 1 3 Drive bracket and spring clip CV3106 1 1 4 PC board CC CV3108CC 1 5 Drive gear 12 x 36 CV3110 3 6 Drive gear cover CV3109 1 7...

Страница 15: ...2 Drive cap assembly CV3004 1 3 O ring 228 CV3153 1 4 1 piston assembly down flow CV3011 1 1 piston assembly up flow CV3011 01 1 1 25 piston assembly down flow CV3407 1 5 Regenerant piston CV3174 1 6...

Страница 16: ...1 quick connect CV3151 2 2 Split ring CV3150 2 3 O ring 215 CV3105 2 4 Bypass rotor 1 CV3145 2 5 Bypass cap CV3146 2 6 Bypass handle CV3147 2 7 Bypass rotor seal retainer CV3148 2 8 O ring 135 CV3152...

Страница 17: ...01 1 7 0 7 DLFC for 3 4 elbow CV3162 007 1 1 0 DLFC for 3 4 elbow CV3162 010 1 1 3 DLFC for 3 4 elbow CV3162 013 1 7 DLFC for 3 4 elbow CV3162 017 2 2 DLFC for 3 4 elbow CV3162 022 2 7 DLFC for 3 4 el...

Страница 18: ...A 5 6 Injector Assembly Item Description Part Number Quantity 1 Refill port plug assembly CV3195 01 1 2 Elbow locking clip CH4615 1 3 Tube insert 3 8 CJCP P 6 1 4 Nut 3 8 CJCPG 6PBLK 1 5 Elbow cap 3 8...

Страница 19: ...r assembly Red CV3010 1D Injector assembly White CV3010 1E Injector assembly Blue CV3010 1F Injector assembly Yellow CV3010 1G Injector assembly Green CV3010 1H Injector assembly Orange CV3010 1I Inje...

Страница 20: ...w set CH1018 1 3 474 air check assembly 1 2 x 48 CH4500 48 1 4 474 float assembly 32 with two grommets CH4640 32 1 5 474 safety brine valve with 0 5 gpm flow control CH4600 50 1 6 Cap 4 brine well CH7...

Страница 21: ...Quantity 1 474 0 5 gpm flow control CH4655 1 2 O ring 019 CH3163 1 3 3 8 elbow cap CH4613 1 1 2 elbow cap CH4612 4 Elbow locking clip CH4615 1 5 3 8 compression nut CJCPG 5PBLK 1 1 2 compression nut C...

Страница 22: ...Injector and Bypass Caps 4 Loosening Quick Connect Nuts Item Description Part Number Quantity 1 Salt and tank cover must be ordered together CG2197 01 1 2 Windsor cabinet white with black lids CG2724...

Страница 23: ...tem Description Part Number Quantity 1 Nut 1 quick connect CV3151 1 1 Nut 1 quick connect CV3151 1 2 Split ring CV3150 1 2 Split ring CV3150 1 3 O ring 215 CV3105 1 3 O ring 215 CV3105 1 4 Fitting CV3...

Страница 24: ...100 F 0 5 37 7 C 33 100 F 0 5 37 7 C 33 100 F 0 5 37 7 C 33 100 F 0 5 37 7 C 33 100 F 0 5 37 7 C 33 100 F Electrical Requirements 110 V 50 60 Hz 110 V 50 60 Hz 110 V 50 60 Hz 110 V 50 60 Hz 110 V 50...

Страница 25: ...0 5 37 7 C 33 100 F Electrical Requirements 110 V 50 60 Hz 110 V 50 60 Hz Pipe Size 3 4 brass 3 4 brass Total Dimension Media Tank width x height 25 4 cm x 11 71 cm 10 x 44 25 4 cm x 137 1 cm 10 x 54...

Страница 26: ...0 gpm 15 1 lpm 5 0 gpm 18 9 lpm 8 0 gpm 30 3 lpm Peak Flow 5 0 gpm 18 9 lpm 6 0 gpm 22 7 lpm 8 0 gpm 30 3 lpm 5 0 gpm 18 9 lpm 6 0 gpm 22 7 lpm 9 0 gpm 34 1 lpm Backwash Flow 5 0 gpm 18 9 lpm 5 0 gpm...

Страница 27: ...st minutes with U and V buttons 5 Press NEXT to complete and return to normal operation Bypass To shut off water to the system position arrow handles as shown in the bypass operation diagram below If...

Страница 28: ...y does not cover change in water test mis application of media use of mineral cleaners in brine tank including salt additives lack of maintenance or any other acts of God VIQUA will not be responsible...

Страница 29: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com...

Отзывы: