A 5-micron (nominal) sediment filter must be installed upstream 
of (before) any UV system.

• 

This product is for 

indoor use only

. Keep all components clean 

and dry.

• 

Clean the sleeve regularly for optimum performance.

KEY INFORMATION YOU SHOULD KNOW:

Congratulations. By purchasing this system, you 
have taken the first step in ensuring safe drinking 
water. Designed using the most advanced UV 
technology available today, your UV system is 
designed to provide you with years of trouble free 
operation with minimal maintenance required.

Ultraviolet Water Purification System

Owner’s Manual

Sterilight® SV50 model is USEPA UVDGM 

2006 validated.

S80, SM80, SV50

Date of installation:   

Installed by: 

Installer phone#:          

Serial #:                     

(Found on label on side of Power Supply)

425 Clair Road West, Guelph, ON N1L 1R1 Canada

t. 

519 763 1032  

t.f.

 1 800 265 7246  

f. 

519 763 5069  www.viqua.com

July 2010

P/N 520150-R revD

Содержание Sterilight S80

Страница 1: ...ng water Designed using the most advanced UV technology available today your UV system is designed to provide you with years of trouble free operation with minimal maintenance required Ultraviolet Wat...

Страница 2: ...This product must be grounded If it should malfunction or breakdown grounding provides a path of least resistance for electric current to reduce the risk of electrical shock This system is equipped wi...

Страница 3: ...Components 4 Specifications 5 Dimensions and layout 7 Installation 9 Installing the UV system 9 Disinfecting the water lines 11 Operation 14 Control panel 14 Troubleshooting 15 Low UV alarms 16 Maint...

Страница 4: ...0 SM80 S80 Part S37RL AM Chamber Power cord Part 602636 120V Part 602637 230V For replacement components please contact your installer listed on the front of this manual or contact VIQUA directly for...

Страница 5: ...al ONLY Other Chamber material 316L SST Rated service life of lamp 2 years General All Models SV50 SM80 S80 Rated flow dose of 30 mJ cm2 up to 80 gpm 265 lpm up to 80 gpm 265 lpm Rated flow dose of 40...

Страница 6: ...Yes Solenoid valve Optional Optional Optional Controls Audible alarm mute button Yes Yes Yes New lamp button Yes Yes Yes Lamp age indicator Yes Yes Yes Lamp operation indicator Yes Yes Yes Power suppl...

Страница 7: ...A B C L L S D 6 1 2 3 5 4 12 13 10 11 7 9 Sampling and shut off valves fittings and pre treatment equipment not included L Model SV50 41 103cm 12 30cm 4 10cm 72 182cm 6 5 16 5cm 13 33cm 48 122cm SM80...

Страница 8: ...noid valve installation of an approved ground strap is required This ground strap will maintain continuity between the lines that have been cut to install the solenoid Check your local electrical code...

Страница 9: ...al of the lamp and sleeve Make all necessary plumbing connections Attach chamber to wall vertically Install screws 37 5 apart 4 1 3 2 10 Wet O ring with water then place over top end of sleeve 5 6 7 8...

Страница 10: ...round Fault Circuit Interrupter GFCI 4 16 10 4cm 1 2 1 2 Do not touch glass with bare hands Be sure to rotate lamp completely Let water flow to one faucet or other water outlet then close the outlet a...

Страница 11: ...ntaminated it is critical that these water lines be chemically disinfected Disinfection of the water lines is therefore required after initial system installation and following any period of time duri...

Страница 12: ...water if present to flow until you can smell bleach then stop the flow Repeat procedure at all water outlets Remember to include all faucets washing machines toilets outside taps and other water outl...

Страница 13: ...INSTALLATION OVERVIEW OPERATION Plug sensor into blue jack 21 Flush all water outlets until bleach can no longer be smelled at least 5 minutes 18 20 22 17 19 23 13...

Страница 14: ...stem again UV dose is below minimum required see Low UV Alarm section Sensor inactive due to lamp or power supply failure Solenoid valve open If equipped with solenoid Not applicable Solenoid valve di...

Страница 15: ...moist air on cold chamber slow accumulation O ring damaged deteriorated or incorrectly installed Sleeve bolt not tight enough Control humidity or relocate unit Inspect and replace if deteriorated Ensu...

Страница 16: ...and SM80 Series are equipped with a unique patented self test sensor Simply press the test button located at the top of the sensor and hold until the audible alarm stops usually about 5 seconds If the...

Страница 17: ...eaning is required follow the instructions below and re install the current lamp Lamp replacement The amount of UV light created by the lamp decreases over time requiring that the lamp be replaced The...

Страница 18: ...N OVERVIEW WARRANTY MAINTENANCE 4 Let the system cool for 10 minutes 3 2 6 5 1 Solenoid representative only Not on all systems Solenoid 10 7 Close after all water has drained 8 9 Pinch wireform to rel...

Страница 19: ...ely cleaned or if it appears scratched or cracked 13 1 2 1 12 2 11 Do not touch glass with bare hands 2 16 Remove sleeve Water will escape have bucket under chamber 14 Sleeve removal tool Insert sleev...

Страница 20: ...lly rotated until positive stop 23 1 2 Ensure sleeve bolt is fully rotated until positive stop 26 1 2 Ensure sleeve bolt is fully rotated until positive stop 21 Do not touch glass with bare hands Inse...

Страница 21: ...ERATION 31 33 If lamp was replaced Press and hold New Lamp button for 5 seconds until you hear a beep 35 Disinfect the water lines Refer to Disinfecting the Water Lines in Installation section 36 34 3...

Страница 22: ...mes equipped with one functioning and one spare 250V 2 5A fuse To access the fuses first unplug system and disconnect the power cord from the power supply Remove the fuse door by pushing in the tab on...

Страница 23: ...riginal lamps sleeves and UV sensors to be free from defects in material and workmanship for a period of one 1 year from the date of purchase During this time we will repair or replace at its option a...

Страница 24: ...Printed in Canada Copyright 2010 VIQUA aTrojanTechnologies Company Guelph ON Canada Sterilight SV50 model is USEPA UVDGM 2006 validated...

Страница 25: ...Imprim au Canada Tous droits r serv s 2010 VIQUA a Trojan Technology Company Guelph On Canada Sterilight mod le SV50 Certifi USEPA UVDGM 2006...

Отзывы: