Viqua S2Q-P/12VDC Скачать руководство пользователя страница 15

Manufacturer’s Warranty

15

Section 9

Manufacturer’s Warranty

Our Commitment

VIQUA is committed to ensuring your experience with our products and organization exceeds your expectations. We have 

manufactured your UV disinfection system to the highest quality standards and value you as our customer. Should you 

need any support, or have questions about your system, please contact our Technical Support team at 1.800.265.7246 or 

[email protected]

 and we will be happy to assist you. We sincerely hope you enjoy the benefits of clean, safe 

drinking water after the installation of your VIQUA disinfection system.

How to Make a Warranty Claim

Note: 

To maximise the disinfection performance and reliability of your VIQUA product, the system must be properly sized, 

installed and maintained. Guidance on the necessary water quality parameters and maintenance requirements can 

be found in your Owner’s Manual. 

In the event that repair or replacement of parts covered by this warranty are required, the process will be handled by your 

dealer. If you are unsure whether an equipment problem or failure is covered by warranty, contact our Technical Support 

team at 1.800.265.7246 or e-mail 

[email protected]

. Our fully trained technicians will help you troubleshoot the 

problem and identify a solution. Please have available the model number (system type), the date of purchase, the name of 

the dealer from whom you purchased your VIQUA product (“the source dealer”), as well as a description of the problem 

you are experiencing. To establish proof of purchase when making a warranty claim, you will either need your original 

invoice, or have previously completed and returned your product registration card via mail or online.

Specific Warranty Coverage

Warranty coverage is specific to the VIQUA range of products. Warranty coverage is subject to the conditions and 

limitations outlined under “

General Conditions and Limitations

”.

Ten-Year Limited Warranty for VIQUA UV Chamber

VIQUA warrants the UV chamber on the VIQUA product to be free from defects in material and workmanship for a period of 

ten (10) years from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective VIQUA 

UV chamber. Please return the defective part to your dealer who will process your claim.

Three-Year Limited Warranty for Electrical and Hardware Components

VIQUA warrants the electrical (controller) and hardware components to be free from defects in material and workmanship 

for a period of three (3) years from the date of purchase. During this time, VIQUA will repair or replace, at its option, any 

defective parts covered by the warranty. Please return the defective part to your dealer who will process your claim.

One-Year Limited Warranty for UV lamps, Sleeves, and UV Sensors

VIQUA warrants UV lamps, sleeves, and UV sensors to be free from defects in material and workmanship for a period of 

one (1) year from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective parts 

covered by the warranty.Your dealer will process your claim and advise whether the defective item needs to be returned for 

failure analysis.

Note: 

Use only genuine VIQUA replacement lamps and sleeves in your system. Failure to do so may seriously 

compromise disinfection performance and affect warranty coverage.

General Conditions and Limitations

None of the above warranties cover damage caused by improper use or maintenance, accidents, acts of God or minor 

scratches or imperfections that do not materially impair the operation of the product. The warranties also do not cover 

products that are not installed as outlined in the applicable Owner’s Manual.
Parts repaired or replaced under these warranties will be covered under warranty up to the end of the warranty period 

applicable to the original part.
The above warranties do not include the cost of shipping and handling of returned items.The limited warranties described 

above are the only warranties applicable to the VIQUA range of products. These limited warranties outline the exclusive 

remedy for all claims based on a failure of or defect in any of these products, whether the claim is based on contract, tort 

(including negligence), strict liability or otherwise. These warranties are in lieu of all other warranties whether written, oral, 

implied or statutory. Without limitation, no warranty of merchantability or of fitness for a particular purpose shall apply to any 

of these products.
VIQUA does not assume any liability for personal injury or property damage caused by the use or misuse of any of the 

above products. VIQUA shall not in any event be liable for special, incidental, indirect or consequential damages. VIQUA’s 

liability shall, in all instances, be limited to repair or replacement of the defective product or part and this liability will 

terminate upon expiration of the applicable warranty period.

Содержание S2Q-P/12VDC

Страница 1: ...f 1 519 763 5069 e mail info viqua com www viqua com Models S1Q PA S2Q PA S5Q PA S8Q PA S2Q P 12VDC S5Q P 12VDC NSF Standard 55 Class B Validated Models SV5Q PA SV8Q PA Owner s Manual Powered by Syste...

Страница 2: ...y should you insist on genuine factory supplied VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV disinfection equip...

Страница 3: ...started Warning This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm DANGER Failure to follow these instructions will resul...

Страница 4: ...d inhalation or ingestion of the debris and avoid exposure to eyes and skin Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury Obey local regulations and guid...

Страница 5: ...r long consistent life 9000 hours S287RL S1Q PA S330RL S2Q PA S463RL S5Q PA SV5Q PA S810RL S8Q PA SV8Q PA 7 Controller for 100 240V models only BA ICE S S1Q PA S2Q PA S5Q PA S8Q PA SV5Q PA SV8Q PA 8 C...

Страница 6: ...it may be exposed to the weather Install the disinfection system on cold water line only before any branched lines A 5 micron sediment filter must precede the disinfection system Ideally the disinfect...

Страница 7: ...tain the manufacturers rated flow The flow restrictor should be installed on the outlet port and is designed to be installed in one direction only Ensure that the flow of the water matches the flow di...

Страница 8: ...a leak shut water off drain cell remove the retaining nut wipe the O ring and threads Clean and re install 7 Once it is determined that there are no leaks plug the system into the ground fault interru...

Страница 9: ...ocedure for any other conditioners that may form a part of the pre treatment for the UV unit 2 The above disinfection procedure will result in a massive chlorine residual far in excess of the 0 5 to 1...

Страница 10: ...org for UV lamp disposal DO NOT use water during replacement of UV lamp 1 Shut off the water line to chamber and release system pressure before servicing 2 0 30 15 45 10 mins Disconnect main power sou...

Страница 11: ...ring 4 Carefully remove O ring adhering to the quartz sleeve Remove the quartz sleeve 5 Mild Acid Clean the quartz sleeve with a cloth soaked in CLR vinegar or some other mild acid and then rinse wit...

Страница 12: ...refer to Section 4 1 5 1 3 Resetting UV lamp Life Refer to Section 4 1 Note Even though the alarm on the system can be deferred for a period of time it is important to address each and every alarm co...

Страница 13: ...d or UV sensor Ensure O ring is in place check for cuts or abrasions clean O ring moisten with water lubricant and re install replace if necessary 410867 Condensation on UV chamber caused by excessive...

Страница 14: ...1 cm x 6 4 cm 7 3 x 3 2 x 2 5 18 6 cm x 8 1 cm x 6 4 cm 7 3 x 3 2 x 2 5 Controller 12 VDC 13 5 cm x 4 3 cm x 5 8 cm 5 3 x 1 7 x 2 3 13 5 cm x 4 3 cm x 5 8 cm 5 3 x 1 7 x 2 3 Inlet Outlet Port Size1 1...

Страница 15: ...Hardware Components VIQUA warrants the electrical controller and hardware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During...

Страница 16: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com...

Отзывы: