background image

Safety Information

3

Section 1

Safety Information

These are the original instructions.Please read this entire manual before operating this equipment. Pay attention to all 
danger, warning, and caution statements in this manual. Failure to do so could result in serious personal injury or damage to 
the equipment.

Make sure that the protection provided by this equipment is not impaired. DO NOT use or install this equipment in any 
manner other than that specified in the installation manual.

1.1 Potential Hazards:

Read all labels and tags attached to the system. Personal injury or damage to the system could occur if not observed.

1.2 Safety Precautions:

Waste electrical and electronic equipment (WEEE). This symbol 
indicates that you should not discard wasted electrical or electronic 
equipment (WEEE) in the trash. For proper disposal, contact your local 
recycling/reuse or hazardous waste center.

This symbol indicates not to store any combustible or flammable 
material close to the system.

This symbol indicates there is Mercury present.

This symbol indicates that the contents of the transport package are 
fragile and the package should be handled with care.

This is the safety alert symbol. Obey all safety messages that follow 
this symbol to avoid potential injury. When on the equipment, refer to 
the Operational and Maintenance manual for additional safety 

This symbol indicates safety glasses with side protection is required for 
protection against UV exposure.

This symbol indicates a risk of electrical shock and/or electrocution 
exists.

This symbol indicates gloves must be worn.

This symbol indicates the marked equipment may contain a 
component that can eject forcibly. Obey all procedures to safely 
depressurize.

This symbol indicates safety boots must be worn.

This symbol indicates the system is under pressure.

This symbol indicates the operator must read all available 
documentation to perform required procedures.

This symbol indicates there is a potential UV hazard. Proper protection 
must be worn.

This symbol indicates the plumber must use copper piping.

This symbol indicates the marked item could be hot and should not be 
touched without care.

This symbol indicates that the system should only be connected to a 
properly grounded, grounding-type controller receptacle that is 
protected by a Ground Fault Circuit Interrupter (GFCI).

This symbol indicates there is a potential for VERY hot water when 
flow is started.

Warning: This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.

D A N G E R

Failure to follow these instructions will result in serious injury or death.

  •

Electric Shock:

 To avoid possible electric shock, special care should be taken since water is present near the electrical equipment. Unless a 

situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting sections, DO NOT attempt repairs yourself, 
refer to an authorized service facility.

  •

GROUNDING: 

This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric

current to reduce the risk of electrical shock. This system is equipped with a cord having an equipment-grounding conductor and a grounding plug. 
The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. 
Improper connection of the equipment-grounding conductor can result in a risk of electrocution. Check with a qualified electrician or service 
personnel if you are in doubt as to whether the outlet is properly grounded. DO NOT modify the plug provided with this system – if it does not fit in 
the outlet, have a proper outlet installed by a qualified electrician. DO NOT use any type of adapter with this system.

  •

GROUND FAULT CIRCUIT INTERRUPTER PROTECTION

: To comply with the National Electrical Code (NFPA 70) and to provide additional 

protection from the risk of electric shock, this system should only be connected to a properly grounded, grounding-type controller receptacle that is 
protected by a Ground Fault Circuit Interrupter (GFCI) or to a residual current device (RCD) having a rated residual operating current not exceeding 
30 mA. Inspect operation of GFCI as per manufacturer’s suggested maintenance schedule.

  •

DO NOT operate the disinfection system if it has a damaged cord or plug, if it is malfunctioning or if it has been dropped or damaged in any manner.

  •

DO NOT use this disinfection system for other than intended use (potable water applications). The use of attachments not recommended or sold by 
the manufacturer / distributor may cause an unsafe condition.

  •

DO NOT install this disinfection system where it will be exposed to the weather or to temperatures below freezing.

  •

DO NOT store this disinfection system where it will be exposed to the weather.

  •

DO NOT store this disinfection system where it will be exposed to temperatures below freezing unless all water has been drained from it and the 
water supply has been disconnected.

Hg

UV

Cu

Содержание K Plus

Страница 1: ... 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com Models H K Plus Models H K PRO Models PRO10 PRO20 PRO30 PRO50 Owner s Manual Powered by System Tested and Certified by NSF International against CSA B483 1 and NSF ANSI 55 for Disinfection Performance Class A 602936_RevAF ...

Страница 2: ...Why should you insist on genuine factory supplied VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV disinfection equipment An increasing number of calls to VIQUA Technical Support are connected with non genuine lamps being used unknowingly as replacements Damage arising from the use of non genuine lamps poses a saf...

Страница 3: ...ted Warning This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm DANGER Failure to follow these instructions will result in serious injury or death Electric Shock To avoid possible electric shock special care should be taken since water is present near the electrical equipment Unless a situation is encountered that is expl...

Страница 4: ...en avoid inhalation or ingestion of the debris and avoid exposure to eyes and skin Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury Obey local regulations and guidelines for the removal and disposal of mercury waste N O T I C E The UV lamp inside the disinfection system is rated at an effective life of approximately 18000 hours To ensure continuous prote...

Страница 5: ...660020 R PRO50 650709 005 H 660019 R K 650709 004 H 660018 R K 2 Top Bolt and Wireform 602916 602896 Used for all systems 3 Lamp 602854 PRO10 602855 PRO20 H H 602856 PRO30 50 K K 4 Sleeve 602974 PRO10 602975 PRO20 H H 602976 PRO30 50 K K 5 CoolTouch Fan 650630 Used for all systems 6 Chamber Used for all systems 7 O ring 002233 Used for all systems 1 2 3 4 6 7 8 9 11 12 13 14 7 10 5 ...

Страница 6: ...sion and Layout Item Description Function 1 Sample Valve Allows for sampling of raw water 2 Shut off Valve Allows for ease of maintenance of pre treatment equipment 3 Pre Treatment Pre treatment allows the UV system to operate effectively The water should meet certain water quality parameters before entering UV System 4 Bypass shut off valve Bypass line and valve are optional Intended to provide e...

Страница 7: ...emoves excess heat from water in chamber during periods without water flow 12 Sample valve Allows for sampling of water immediately following UV treatment necessary in order to confirm proper operation of UV system 13 Shut off valve Allows maintenance of UV system 14 Controller Powers and controls the UV lamp and other devices Provides human interface displaying information and allowing control in...

Страница 8: ... 5 Note Ensure chamber is installed with green arrows pointing upwards 2 2 Connect Flow Meter Sensor PRO10 20 30 models only to chamber using 1 unions supplied Note LED must face up Ensure proper length of straight pipe 1 0 Diameter at inlet side of Flow Meter Sensor and use a 1 to 1 Reducing Coupler not supplied 3 Install the sensor to the UV system for PRO models only Note DO NOT use wrench to t...

Страница 9: ...end of sleeve Reconnect the sleeve bolt and install screw 10 10 2 1 Hg UV Install and rotate the lamp into the sleeve assembly Ensure to rotate the lamp completely Note Do not touch glass with bare hands 11 11 4 16 10 4cm Install the controller unit to the wall Ensure that the controller is installed higher than the chamber and away from all water sources 12 12 1 2 3 Connect UV sensor into blue ja...

Страница 10: ...ect only the filter housing s to the unit 7 Open each faucets and turn on water supply Allow water to fill the chamber 8 0 30 15 45 30 mins Turn on the cold water supply followed by hot water if available until you smell the bleach Close all faucets and allow bleach to settle in the water lines for 30 minutes 9 With all faucets closed remove filter housing s using sump wrench 10 10 1 2 Reinstall t...

Страница 11: ... maximum disinfection Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures NOTICE Do not use water during replacement of UV lamp 1 1 1 2 Close all faucets and water supply Press the pressure button to release the pressure from the cartridges 2 0 30 15 45 10 mins Disconnect main power source and allow the unit to power down for 10 min...

Страница 12: ... 1 2 Remove the UV sensor from the unit Submerge the end of the sensor in the commercial scale remover for 30 minutes Clean the sensor with a cotton swab and spray with water For Basic model skip to step 10 10 10 Lock the wire form into position 11 Restore Power Press and hold the New Lamp button for 5 seconds till you hear a beep Note Lamp ignition may take up to 25 seconds 12 12 Turn on the wate...

Страница 13: ... scratched or cracked then replace the sleeve 8 3 1 2 Connect the sleeve bolt at the bottom of the sleeve assembly 9 Reinstall the sleeve with arrow pointing up Note DO NOT rotate sleeve and touch glass with bare hands 10 10 Reinstall the new lubricated O rings over the top end of the sleeve 11 11 2 1 Connect the sleeve bolt to the top of the sleeve assembly 12 12 1 2 Remove the sleeve bolt at the...

Страница 14: ... other side Procedure 4 4 Flow Meter Sensor Maintenance Inspect Flow Meter Sensor periodically to ensure that there is no fouling and the paddle wheel spins freely with no resistance If paddle wheel does not spin freely or is loose the sensor should be returned for service and calibration It is recommended that the Flow Meter Sensor be returned for calibration every two years to ensure accurate sy...

Страница 15: ...ot installed properly Ensure lamp harness ground is inserted into chamber ground terminal Controller failure replace controller Lamp inactive due to controller failure 3 Operating normally Not applicable Fan disconnected reconnect Fan turning slower than required unplug system clean blades using a Q tip Fan damaged replace fan Not applicable 4 Operating normally Note During the lamp warm up the in...

Страница 16: ... UV system is acting as a breeding ground for pathogens Ensure UV is the last piece of treatment equipment Pathogens are residing in the distribution lines post UV Ensure all distribution lines have been disinfected with chlorine Refer to Section 3 2 Recontamination from pipe dead ends Remove any pipe dead ends and flush with chlorine Refer to Section 3 2 Flow Meter Sensor red status LED Detect Fl...

Страница 17: ...ure 104 ºF 40 ºC Minimum ambient air temperature 32 ºF 0 ºC Maximum humidity 100 Maximum hardness 120 ppm 7 grains per gallon Maximum iron 0 3 ppm Minimum UVT 75 Installation Vertical ONLY Others Chamber material 316L SST Rated service life of lamp up to 2 years PRO50 has a minimum UVT rating of 85 PRO10 PRO20 PRO30 PRO50 H H K K Rated flow for NSF Std 55 Class A 10 gpm 38 lpm 2 2 m3 hr 20 gpm 76 ...

Страница 18: ...nal Flow Meter Sensor PRO10 20 30 Models only Yes No No Controls Audible alarm mute button Yes Yes Yes New lamp button Yes Yes Yes Lamp age indicator Yes Yes Yes Lamp operation indicator Yes Yes Yes Controller operation indicator Yes Yes Yes Solenoid operation indicator Yes Yes Yes Fan operation indicator Yes Yes Yes Sensor reading indicator Yes Yes No NSF ANSI certification PRO10 20 30 models onl...

Страница 19: ...d Hardware Components VIQUA warrants the electrical controller and hardware components to be free from defects in material and workmanship for a period of five 5 years from the date of purchase During this time VIQUA will repair or replace at its option any defective parts covered by the warranty Please return the defective part to your dealer who will process your claim One Year Limited Warranty ...

Страница 20: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com ...

Отзывы: