VARIPOOL
23
Option : flow sensor
if you need a flow control (Heat pump / treatment), you must use a flow detector installed
on the pipe at the pump discharge - see reference below.
Flow collar
ref : FLOW50
Страница 1: ...15 Rue des Marais 44310 ST Philbert de Gd Lieu www acis france com VARIPOOL VARIATEUR DE FR QUENCE 50963 E 50964 E 50965 E 50966 E 11 2019 NOTVARIPOOL...
Страница 2: ...CONSIGNES DE S CURIT 3 2 CARACT RISTIQUES TECHNIQUES 4 3 AVANT L INSTALLATION 5 4 RACCORDEMENT A LA POMPE DE PISCINE 5 6 5 PARAM TRES ET FONCTIONNEMENT 7 6 CODES ERREURS 11 7 EXCLUSIONS 11 8 R GLEMEN...
Страница 3: ...iques d poser au centre de recyclage 1 IMPORTANTES CONSIGNES DE S CURIT Pour tirer le meilleur parti de ce dispositif conome en nergie et afin d viter le risque potentiel d incendie de chocs lectrique...
Страница 4: ...1 1 kW Max 2 2 kW Max 1 1 kW Max 2 2 kW Sortie tension 1ph 0 240V 1ph 0 240V 3ph 0 240V 3ph 0 240V Type de pompe Monophas e Monophas e Tri Tri Max courant 6 A max 12 A max 4 5 A max 8 A max Vitesse 1...
Страница 5: ...oqu e ou un espace clos avec un d bit d air limit peut entra ner une surchauffe ou un dysfonctionnement potentiel de l onduleur 4 RACCORDEMENT LA POMPE DE PISCINE Merci de bien suivre ces tapes ainsi...
Страница 6: ...ntilateur quand l appareil est en fonctionnement et attendre au moins 30 minutes apr s usage Gardez le hors de port e des enfants En raison de composants de conversion haute tension contenues dans l a...
Страница 7: ...gurer jusqu 4 plages horaires pour un fonctionnement quotidien chacune avec une vitesse individuelle Mode Gamme de vitesse Vitesse par d faut Nuit Petite vitesse V1 1200 2900 tr min 2000 tr min Jour M...
Страница 8: ...er sur M Au rel chement de la touche on passe la vitesse suivante en boucle V3 V2 V1 V3 lavage jour nuit lavage 4 Pour modifier les vitesses il faut utiliser les touches pendant le fonctionnement de c...
Страница 9: ...que les 4 programmes sont bien enregistr s en les faisant d filer ou Si des plages horaires se chevauchent l enregistrement sera invalide et l appareil fonctionnera sur le dernier r glage valide enreg...
Страница 10: ...autres Voir tableau ci dessus Pour changer la valeur des vitesses il faut proc der comme suit En mode off appuyer 3 fois sur les touches simultan ment R appuyer pour faire d filer les codes CODE Par...
Страница 11: ...re interne Quand la temp rature sera retomb e 65 C l onduleur reprendra la vitesse pr r gl e 2 Lorsque les causes sont E002 E101 E103 l appareil recommencera fonctionner automatiquement cependant la q...
Страница 12: ...VARIPOOL Option d tecteur de d bit Si vous avez besoin d un asservissement li au d bit P A C traitement vous devez utiliser un d tecteur de flux install sur la canalisation au refoulement de la pompe...
Страница 13: ...15 Rue des Marais 44310 ST Philbert de Gd Lieu France www acis france com VARIPOOL FREQUENCY INVERTER 50963 E 50964 E 50965 E 50966 E 11 2019 NOTVARIPOOL...
Страница 14: ...TENTS 1 IMPORTANT SAFETY INSTRUCTIONS 15 2 TECHNICAL DATA 16 3 BEFORE INSTALLATION 17 4 CONNECTING TO POOL PUMP 17 5 SETTINGS OPERATION 18 6 PROTECTON ERROR CODES 20 7 EXCLUSIONS 21 8 WEEE LEGISLATION...
Страница 15: ...electrical shock Do not touch the heat sink e Waste Dispose at recycling centre 1 IMPORTANT SAFETY INSTRUCTIONS To make the best use of this energy saving device and to avoid potential risk of fire e...
Страница 16: ...kW Max 1 1 kW Max 2 2 kW OutputVoltage 1ph 0 240V 1ph 0 240V 3ph 0 240V 3ph 0 240V Pump type Single phase Single phase Three Three Max current Max 6 A Max 12 A Max 4 5 A Max 8 A Speed range 1200 2900...
Страница 17: ...ir flow may cause overheating or potential operational failure of the inverter 4 CONNECTING TO POOL PUMP Please follow these steps and the wiring diagram for correct connection The warranty may be com...
Страница 18: ...hile the device is in operation or until at least 30 mins after it has been switched off Keep it out of reach of children Because of high voltage conversion components contained in the device do not t...
Страница 19: ...eed Night Low V1 1200 2900 rpm 2000 rpm Day Medium V2 1200 2900 rpm 2400 rpm Backwash High V3 1200 2900 rpm 2900 rpm Switch on the device 1 Press 3 seconds the button padlock M to unlock the keyboard...
Страница 20: ...lid timer setting During timer setting if you want to abandon it hold 3 seconds 5 Press 3 seconds to enter timer settings Note If inactivate for 1 minute the screen will lock automatically Hold on 3 s...
Страница 21: ...ress the keys 3 times simultaneously 6 PROTECTON ERROR CODES CODE Default speed setting Manual setting 1 Priming time 1 mn 0 10 mn 2 Minimum setting speed 1200 rmp 1200 2900 rmp 3 H washing speed 2900...
Страница 22: ...nappropriate incorrect installation or mismatching of the product to pool pumps that are not compatible The manufacturer reserves the right to change the specification of the product or its perfor man...
Страница 23: ...VARIPOOL 23 Option flow sensor if you need a flow control Heat pump treatment you must use a flow detector installed on the pipe at the pump discharge see reference below Flow sensor collar ref FLOW50...
Страница 24: ...VARIPOOL 24 15 Rue des Marais 44310 ST Philbert de Gd Lieu www acis france com...