VIPA SLIO FM 050-1BB30 Скачать руководство пользователя страница 29

Manual VIPA System SLIO 

Chapter 2   Hardware description 

HB300E - FM - RE_050-1BB30 - Rev. 10/30 

 

2-3 

Structure 

 

1

3

5

4

6

7
8

9

2

 

[1] 
[2] 
[3] 
[4] 
[5] 
[6] 
[7] 
[8] 
[9] 

Locking lever terminal module 
Labeling strip 
Backplane bus 
LED status indication 
DC 24V power section supply 
Electronic module 
Terminal module 
Locking lever electronic module 
Terminal 

 

LED 

Color 

Description 

RUN green RUN

MF   

MF red 

 

 

Bus communication is OK  
Module status is OK 

 

 

Bus communication is OK 
Module status reports an error 

 

 

Bus communication is not possible 
Module status reports an error 

 

 

Error at bus power supply 

 

 

Error in parameterization (see Basics) 

 

 

 

Status indication 

 

RUN

MF

A0

B0

A1

B1

 

A0 green 

 

Counter 0: Digital input 1 A0/pulse is set 

 

B0 green 

 

Counter 0: Digital input 5 B0/direction is set 

 

A1 green 

 

Counter 1: Digital input 4 A1/pulse is set 

 

B1 green 

 

Counter 1: Digital input 8 B1/direction is set 

on: 

   off: 

   blinks with 2Hz: 

 

050-1BB30 

Содержание SLIO FM 050-1BB30

Страница 1: ...VIPA System SLIO FM 050 1BB30 Manual HB300E_FM RE_050 1BB30 Rev 10 30 July 2010...

Страница 2: ...c Compatibility Directive 2006 95 EC Low Voltage Directive Conformity is indicated by the CE marking affixed to the product Conformity Information For more information regarding CE marking and Declara...

Страница 3: ...ion for Users 1 2 System conception 1 3 Dimensions 1 6 Installation 1 7 Wiring 1 11 Trouble shooting LEDs 1 14 Installation guidelines 1 15 General data 1 18 Chapter 2 Hardware description 2 1 Propert...

Страница 4: ...Contents Manual VIPA System SLIO ii HB300E FM RE_050 1BB30 Rev 10 30...

Страница 5: ...of the VIPA System SLIO Here you will find the information required to assemble and wire a controller system consisting of System SLIO components Besides the dimensions the general technical data of...

Страница 6: ...lowing guides are available in the manual an overall table of contents at the beginning of the manual an overview of the topics for every chapter The manual is available in printed form on paper in el...

Страница 7: ...anual must be available to all personnel in the project design department installation department commissioning operation The following conditions must be met before using or commissioning the compone...

Страница 8: ...Safety information Manual VIPA System SLIO 4 HB300E FM RE_050 1BB30 Rev 10 30...

Страница 9: ...e information required to assemble and wire a controller system consisting of System SLIO components Besides the dimensions the general technical data of System SLIO will be found Topic Page Chapter 1...

Страница 10: ...ge components thereby causing the module to become inoperable or unusable Modules that have been damaged by electrostatic discharges can fail after a temperature change mechanical shock or changes in...

Страница 11: ...y the electronic power supply may be extended with 2A The System SLIO consists of the following components Bus coupler Periphery modules Power modules Accessories With a bus coupler bus interface and...

Страница 12: ...nic module which is mounted to the terminal module by a save sliding mechanism With an error the defective module may be exchanged for a functional module with standing installation By an integrated c...

Страница 13: ...nderneath the terminal of the terminal module With a flat mounting rail for adaption to a flat mounting rail you may remove the spacer of the shield bus carrier With each bus coupler to protect the ba...

Страница 14: ...bly Manual VIPA System SLIO 1 6 HB300E FM RE_050 1BB30 Rev 10 30 Dimensions 104 109 76 5 48 5 104 109 76 5 15 133 12 9 58 62 12 9 Dimensions in mm Dimensions bus coupler Dimensions periphery module Di...

Страница 15: ...odule The module is fixed to the mounting rail by pushing downwards the locking lever The modules may either separately be mounted to the mounting rail or as block Here is to be considered that each l...

Страница 16: ...with 2A More about this may be found at Wiring Mount the mounting rail Please consider that a clearance from the middle of the mounting rail of at least 80mm above and 60mm below respectively 80mm by...

Страница 17: ...ver may now be mounted at the last module The shield bus carrier available as accessory serves to carry the shield bus to connect cable shields The shield bus carrier is mounted underneath the termina...

Страница 18: ...ripes at both sides to the mounting rail 1 2 3 4 With mounting respectively de mounting of a module group you also have to remove the electronic module of the just mounted right module After mounting...

Страница 19: ...e If one fuse released its electronic module must be exchanged It is recommended to externally protect the power section supply with a fast 10A fuse and the electronic power supply with a fast 4A fuse...

Страница 20: ...at the following backplane bus modules may be placed with a sum current of max 2A Afterwards the power module 007 1AB10 is to be placed again 007 1AB00 Sys DC 5V DC 24V 10A 007 1AB00 Sys DC 5V DC 24V...

Страница 21: ...shields The shield bus carrier is mounted underneath the terminal of the terminal module With a flat mounting rail for adaption to a flat mounting rail you may remove the spacer of the shield bus carr...

Страница 22: ...er module 007 1AB10 More concerning this may be found above at Wiring RUN MF RUN MF RUN MF RUN MF RUN MF RUN MF RUN MF RUN MF RUN MF RUN MF Behavior After PowerON the MF LED of one module respectively...

Страница 23: ...rferencing the environment All System SLIO components are developed for the deployment in hard industrial environments and fulfill high demands on the EMC Nevertheless you should project an EMC planni...

Страница 24: ...g lines must be laid isolated When transmitting signals with small amplitudes the one sided laying of the isolation may be favorable Lay the line isolation extensively on an isolation protected earth...

Страница 25: ...ation one sided Then you only achieve the absorption of the lower frequencies A one sided isolation connection may be convenient if the conduction of a potential compensating line is not possible anal...

Страница 26: ...tic Storage transport EN 60068 2 14 25 70 C Operation Horizontal installation EN 61131 2 0 60 C Vertical installation EN 61131 2 0 60 C Air humidity EN 60068 2 30 RH1 without condensation rel humidity...

Страница 27: ...on In this chapter the counter module 050 1BB30 of the System SLIO is described Here every information about the hardware components of the module may be found The technical data are at the end of the...

Страница 28: ...10 30 Properties 2 counter 32bit AB invertible DC 24V Counting frequency max 400kHz AB 1 2 4 fold evaluation or pulse and direction Input filter configurable Diagnostics function Type Order number De...

Страница 29: ...ption RUN green RUN MF MF red Bus communication is OK Module status is OK Bus communication is OK Module status reports an error Bus communication is not possible Module status reports an error Error...

Страница 30: ...ctively track A of an encoder for 1 2 or 4 fold evaluation 2 DC 24V O DC 24V for encoder 3 0V O GND 4 A1 I Counter 1 A pulse Pulse input for counter signal respectively track A of an encoder for 1 2 o...

Страница 31: ...neously utilizable vertical 4 Input characteristic IEC 61131 type 1 Input data size 12Byte Technical data digital outputs Number of outputs Cable length shielded Cable length unshielded Rated load vol...

Страница 32: ...gnostic functions no Diagnostics information read out possible Module state green LED Module error display red LED Channel error display none Isolation Between channels and backplane bus 9 Insulation...

Страница 33: ...this chapter the deployment of the System SLIO counter module 050 1BB30 is described Here every information required for the deployment may be found Topic Page Chapter 3 Deployment 3 1 Fast introduct...

Страница 34: ...1h s 1 02h 8 CSTS_I 2 Counter 0 Counter status 5402h s 03h 10 CSTS_II 2 Counter 1 Counter status 5403h s 1 04h Output area Addr Name Bytes Function IX SX 0 CCTRL_I 2 Counter 0 Control word 5602h s 01h...

Страница 35: ...C0 Input frequency track B 02h 01h 3101h 02h CH2A 1 C1 Input frequency track A 02h 01h 3102h 03h CH3B 1 C1 Input frequency track B 02h 01h 3103h 04h MODE2_I 1 C0 Counter mode 2 00h 80h 3104h 05h MODE...

Страница 36: ...SW GATE Status software gate set when SW gate is active 3 4 reserved 5 STS_GATE Status internal gate set when internal gate is active 6 reserved 7 STS_C_DN Status set at counter direction backward 8 S...

Страница 37: ...eter may only be transferred at STOP state Byte Function Possible values 0 Input frequency C0 track A 1 Input frequency C0 track B 2 Input frequency C1 track A 3 Input frequency C1 track B 02h 100kHz...

Страница 38: ...ce the I gate SW gate influences I gate 0 0 1 1 with edge 0 1 1 Each counter always starts at 0 When the counter counts forward and reaches the upper count limit and another counting pulse in positive...

Страница 39: ..._C 1 reserved 00h 04h ERR_D 1 reserved 00h 05h CHTYP 1 Channel type 76h 06h NUMBIT 1 Number diagnostics bits per channel 00h 07h NUMCH 1 Number channels of the module 02h 08h CHERR 1 reserved 00h 09h...

Страница 40: ...Chapter 3 Deployment Manual VIPA System SLIO 3 8 HB300E FM RE_050 1BB30 Rev 10 30...