Configuring iSCSI
530-0267-00 Rev 02
7700 Flash Storage Platform Installation Guide 7.6.3.x
89
If this has occurred, after you delete the old node from the iSCSI client and re-discover the target
node, the login process will complete without issue. The following example shows the old node as
deleted and the new target node is discovered, and login succeeds without issue:
Assigning LUNs to an Existing iSCSI Target
If you want to assign a virtual device with (for example, VID=3) to an iSCSI target (with for example,
Target_ID=15), issue the following commands to assign two LUNs (for example, ID=3 and 4) to a
designated target (ID=15).
To assign these LUNs to an existing target, issue the isscli assigntoiscsitarget command as shown:
[root@lab-ib1-cn6 ~]# iscsiadm -m node -o delete -T iqn.2004-
02.com.vmem-concerto.san-array3003-mgb.lab-ib1-cn6-0 -p 192.168.10.106
[root@lab-ib1-cn6 ~]# iscsiadm -m node -o delete -T iqn.2004-
02.com.vmem-concerto.san-array3003-mgb.lab-ib1-cn6-0 -p 192.168.20.106
[root@lab-ib1-cn6 ~]# iscsiadm -m node
iscsiadm: No records found
[root@lab-ib1-cn6 ~]# iscsiadm -m discovery -t st -p 192.168.10.106
192.168.10.106:3260,0 iqn.2004-02.com.vmem-concerto.san-array3003-
mgb.lab-ib1-cn6-15
192.168.20.106:3260,0 iqn.2004-02.com.vmem-concerto.san-array3003-
mgb.lab-ib1-cn6-15
[root@lab-ib1-cn6 ~]# iscsiadm -m node -l
Logging in to [iface: default, target: iqn.2004-02.com.vmem-
concerto.san-array3003-mgb.lab-ib1-cn6-15, portal:
192.168.20.106,3260] (multiple)
Logging in to [iface: default, target: iqn.2004-02.com.vmem-
concerto.san-array3003-mgb.lab-ib1-cn6-15, portal:
192.168.10.106,3260] (multiple)
Login to [iface: default, target: iqn.2004-02.com.vmem-concerto.san-
array3003-mgb.lab-ib1-cn6-15, portal: 192.168.20.106,3260] successful.
Login to [iface: default, target: iqn.2004-02.com.vmem-concerto.san-
array3003-mgb.lab-ib1-cn6-15, portal: 192.168.10.106,3260] successful.
[root@san-array3003-mgb san-array3003-mgb]# isscli assigntoiscsitarget
-v 3 -r 15
Command: assigntoiscsitarget executed successfully.
[root@san-array3003-mgb lab-fil3003-mgb]# isscli assigntoiscsitarget -
v 4 -r 15
Command: assigntoiscsitarget executed successfully
Содержание 7700
Страница 12: ...Preface 6 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 122: ...Appendix A System Reference 116 7700 Series Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 144: ...Appendix C Configuring Replication 138 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 180: ...Appendix G Managing HA Using CLI Commands 174 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 195: ...Korea RFI Statement 530 0267 00 Rev 02 7700 Flash Storage Platform Installation Guide 7 6 3 x 189 Korea RFI Statement ...
Страница 202: ...Appendix H Compliance Information 196 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 208: ...202 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...