STANDARD UNITS
CONFIGURING THE UNIT
The S.A.G.E. Wizard can be used to configure units to the preferred programming mode and
adjust related settings. This configuration should be completed before initial operation or as
changes need to be made. To begin, visit
www.violetdefense.com/wizard
to download the
S.A.G.E. Wizard and computer configuration instructions. After downloading, run the installer
and a shortcut will be placed on computer’s start menu and desktop.
1.
Configure your computer per instructions.
2.
Plug the S.A.G.E. unit into your computer using an Ethernet cable.
3.
Open the S.A.G.E. Wizard and follow the on-screen instructions to configure the unit,
including operational mode, related settings such as length of motion time-out, runtime
for manual or scheduled mode, and scheduling options, such as start-time for scheduled
mode.
4. Once completed, unplug the cable and install the unit. See additional installation
instructions on page 9.
Each standard unit has 3 primary modes available to users. Fixtures must be programmed
before initial use.
• Autonomous Mode:
In this mode, once plugged in, the unit will automatically
activate once the space is unoccupied and continue disinfection on a regular
schedule, adjusting frequency based on level of activity in the space based on the
motion sensor. Users may select the timeout time, which determines how long the
unit will wait until resuming operation after motion is detected.
• Scheduled Mode:
In this mode, the unit will activate at selected time(s) of day
during each 24-hour period. Users may schedule up to 4 start times each day to
operate for a specified run time (i.e. 15 or 30 minutes). Users may select the motion
timeout, which determines how long the unit will wait until resuming operation after
motion is detected. The unit may also be configured to activate a disinfection cycle
immediately when it is powered and then continue with the scheduled operational
time(s).
• Single Cycle Mode:
In this method, users will manually activate the unit to start
a disinfection cycle. The unit will then run its pre-programmed cycle (i.e. 15 or 30
minutes) one time before entering safe mode until power is cycled on and off again.
Users may select the timeout time, which determines how long the unit will wait until
resuming operation after motion is detected.
OPERATIONAL MODES
ST
AND
ARD UNITS
© Copyright 2020 Violet Defense, LLC All Rights Reserved SUV-GEN2-UM2020