User´s Manual DHA V226, November 2021, F. Reim
9
General GROUND-LIFT Jumper
(Accessible from the inside. Mind the SECURITY INSTRUCTIONS):
Ex-works this jumper is set to the LIFT position.
The internal ground potential is “lifted” by means of this jumper.
As a result, the interconnection for DC voltages and lower
frequencies (< 150 Hz) will be cut.
Higher frequencies will be bled off to earth potential through the RC
filter. The LIFT position is helpful in case of hum or jitter caused by
different ground/earth potentials. Of course, full electrical protection
is granted as the case is always connected to ground/earth
potential!
Electrical safety is always ensured, since the earth conductor is
permanently connected to the enclosure!
Please note that with jumpers not in the ex-works
position EMC emission might occur,
for which the user is responsible only!
So, only change these settings when you
know what you are doing!