SP-2000/X-Y
Installation
User Manual
3-13
2.
Connect the input hose and regulator to the nitrogen tank. Close the regula-
tor valve fully. Close the purge valve on the manifold and turn the three T
valves fully CCW.
3.
Remove the yellow dust caps from the three fill valves on the column.
4.
Install a 4” valve extension (packed separately) onto each fill valve.
Tighten the extensions with a crescent wrench - but do not overtighten.
5.
Connect a fill hose to each valve extension. Use one crescent wrench to
hold the valve extension steady and use a second crescent wrench to tighten
the fill hose fitting. Open each T valve by turning it fully clockwise.
6.
With the regulator fully closed (turn CCW), open the main valve on the
nitrogen tank.
7.
Press and hold the Standby/Charge (yellow) button on the pedestal until the
light comes on and stays on.
8.
If you have an older pedestal with a Fill Switch as shown opposite, press
and hold the switch while the pedestal is being pressurized, until the pedes-
tal is powered up in step 11. (In newer pedestals, a set of contacts on the
Standy/Charge switch perform the function of the Fill Switch)
9.
Start increasing the pressure setting on the regulator (turn CW). At approx-
imately 900 psi (63 bar) you will hear a hissing sound indicating that the
three holding chambers are being filled. Keep the regulator set just high
enough to keep the nitrogen flowing but no higher. Listen for leaks at the
fittings, tighten as needed.
10. Have an assistant pull up gently on the payload and column (with around
20-30 lb. of force) from time to time. Make sure that you support and lift
the manifold and fill hoses as the column rises to avoid straining the valve
extensions. Make sure that the hoses do not get caught as the column rises.
Keep nitrogen flowing until the column starts rising on its own and then
immediately close the regulator (turn CCW) to prevent overfilling.
11. Close the main valve on the nitrogen tank completely.
12. Be prepared for the column to go up and down during initialization. Press
Run to power up the pedestal.
Содержание AutoCam SP-2000/X-Y
Страница 10: ...Table Of Contents x This page left blank intentionally ...
Страница 11: ...User Manual 1 1 1 Safety Introduction ...
Страница 21: ...SP 2000 X Y Safety Introduction User Manual 1 11 This page left blank intentionally ...
Страница 28: ...SP 2000 X Y Safety Introduction 1 18 User Manual This page left blank intentionally ...
Страница 29: ...User Manual 2 1 2 Operation ...
Страница 40: ...SP 2000 X Y Operation 2 12 User Manual This page left blank intentionally ...
Страница 41: ...User Manual 3 1 3 Installation ...
Страница 57: ...SP 2000 X Y Installation User Manual 3 17 This page left blank intentionally ...
Страница 63: ...SP 2000 X Y Installation User Manual 3 23 This page left blank intentionally ...
Страница 67: ...User Manual 4 1 4 Maintenance And Repair ...
Страница 71: ...SP 2000 X Y Maintenance And Repair User Manual 4 5 This page left blank intentionally ...
Страница 79: ...SP 2000 X Y Maintenance And Repair User Manual 4 13 This page left blank intentionally ...
Страница 81: ...SP 2000 X Y Maintenance And Repair User Manual 4 15 North Sensors West Sensors ...
Страница 85: ...SP 2000 X Y Maintenance And Repair User Manual 4 19 This page left blank intentionally ...
Страница 91: ...SP 2000 X Y Maintenance And Repair User Manual 4 25 This page left blank intentionally ...
Страница 95: ...SP 2000 X Y Maintenance And Repair User Manual 4 29 This page left blank intentionally ...
Страница 106: ...SP 2000 X Y Index IV This page left blank intentionally ...