background image

4

www.vintageair.com

907173 REV A 5/14/14, PG 4 OF 6

RED

CIRCUIT BREAKER

30 AMP

+

+

-

BLAC

K

RED

WHI

TE

RED

 CHASSIS GROUND 

 A/C

COMPRESSOR 

RELAY

Ignition Switch:

Dash Light:

 

NOTE:

 

MOUNT RELAY

IN DESIRED 

LOCATION

UNDER DASH

 GREEN

 FIREWALL

BLUE

BLUE

RED 

WHITE

VIOLET

(IGNITION HOT

TERMINAL)

IGNITION 

SWITCH

DASH BACK LIGHT+0-12v

TAN

GRAY

BLUE

WHITE

WHITE

RED
RED

 WHITE

COMPRESSOR

BATTERY

NOTE:

 

CONNECT WHITE

WIRES DIRECTLY TO 

(-) BATTERY TERMINAL

BAT

RUN

12V

RED

 GREEN

RED

RED

BLUE

LATCH

BLACK

BINARY

SAFETY

SWITCH

YELLOW

ORANGE

WIRING 

HARNESS

Violet 12V Ign Switch Source (Key On 

Accessory) Position Must Be Switched. 

Tan Wire Used Only With Vintage Air 

Supplied Control Panel With LED Back 

Light.

Binary: Connect As Shown (Typical 

Compressor Wiring). Be Sure 

Compressor Body Is Grounded. 

Trinary Switch: Connect According To 

Trinary Switch Wiring Diagram.

Install With Servo Motor Facing Down, 

As Shown. Note Flow Direction Arrow 

Molded Into Valve Body, And Install 

Accordingly.

White

 

Must Run To (-) Battery. Red May 

Run To (+) Battery Or Starter. Mount 

Circuit Breaker As Close to Battery As 

Possible.

Heater Control Valve:

Binary/Trinary & Compressor:

Circuit Breaker/Battery:

CONTROL 

WIRING 

HARNESS

NOTE: 

YELLOW & ORANGE 

COMING FROM 

HARNESS ARE NOT 

USED. 

WIRING 

HARNESS

GRAY WIRE IS USED FOR 

PROGRAMING CONTROLS 

IF APPLICABLE

WIRING 

HARNESS

                Gen IV Wiring 

Connection Instruction

HEATER

CONTROL VALVE

WARNING: 

ALWAYS MOUNT CIRCUIT BREAKER 

AS CLOSE TO THE BATTERY AS POSSIBLE. 

(NOTE: WIRE BETWEEN BATTERY AND 

CIRCUIT BREAKER IS UNPROTECTED 

AND SHOULD BE CAREFULLY ROUTED 

TO AVOID A SHORT CIRCUIT).

NOTE: HEATER CONTROL 

VALVE CONNECTION AND 

CHASSIS GROUND MAY BE 

LOCATED ON EITHER SIDE 

OF THE FIREWALL. ENSURE

CONNECTOR IS LATCHED 

FIRMLY.

Содержание 46115-VUH

Страница 1: ... instructions on Pages 5 and 6 of this insert B Flow direction follows molded arrow on valve C Connection between heater control valve and wiring adapter may be located in engine bay or passenger compartment Be sure to secure ground ring terminal to chassis ground ATTENTION From Intake Manifold From Heater Core To Water Pump From Heater Control Valve to Heater Core Heater Hose Instructions notices...

Страница 2: ...sensitive to voltage spikes on the power leads which can cause unexpected resets strange behavior and or permanent damage Vintage Air strives to harden our products against these types of electrical noise but there is a point where a vehicle s electrical system can be degraded so much that nothing can help Radio interference capacitors should be available at most auto and truck parts suppliers The...

Страница 3: ...VUR 232002 VUA CIRCUIT BREAKER 30 AMP WIDE OPEN THROTTLE SWITCH OPTIONAL DASH LAMP IF USED Dash Lamp Is Used Only With Type 232007 VUR Harness Warning Always Mount Circuit Breaker As Close to the Battery As Possible NOTE Wire Between Battery and Circuit Breaker Is Unprotected and Should Be Carefully Routed to Avoid a Short Circuit Wide Open Throttle Switch Contacts Close Only at Full Throttle Whic...

Страница 4: ...essor Body Is Grounded Trinary Switch Connect According To Trinary Switch Wiring Diagram Install With Servo Motor Facing Down As Shown Note Flow Direction Arrow Molded Into Valve Body And Install Accordingly White Must Run To Battery Red May Run To Battery Or Starter Mount Circuit Breaker As Close to Battery As Possible Heater Control Valve Binary Trinary Compressor Circuit Breaker Battery CONTROL...

Страница 5: ...ove the small green wire from the heater control valve connector by gently depressing the retaining tab on the metal terminal and withdrawing the wire from the connector Repeat the process for the other 3 wires Using a small flat blade screwdriver gently return the retaining tab on the small green wire s metal terminal to the raised position as shown below Repeat the process for the 2 red wires In...

Страница 6: ...s into place NOTE It does not matter which of the two red wires is used for this step Insert the remaining red wire into Position 2 of the new white heater control valve connector Push the terminal inward until it locks into place Using wire cutters cut the large green wire in two places as shown It will not be used with the new heater control valve NOTE It is not necessary to insulate the ends of...