-1- 

 
 
 

Important Safety Information 

 
 

WARNING 

 

To avoid the risk of electrical shock, property damage, personal injury, or death: 

 

  The power cord must be plugged into a 3-prong grounding type wall 

receptacle, grounded in accordance with the National Electrical Code, 
ANSI/NFPA 70 

– latest edition and local codes and ordinances. 

  It is the personal responsibility of the consumer to have a proper 3-prong wall 

receptacle installed by a qualified electrician. 

  DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER CORD 

GROUNDING PRONG. 

  A separate adequately fused and grounded circuit should be available for this 

appliance. 

  Do not remove any grounding wires from individual components while servicing 

unless the component is to be removed and replaced. It is extremely important 
to replace all grounding wires when components are replaced. 

 

 

 

WARNING 

ELECTRICAL SHOCK HAZARD 

  Disconnect electrical supply from appliance before servicing. 

  Replace all panels before operating. 

  Failure to do so could result in death or electrical shock. 

 
 

Содержание Wine-Mate WM-2520SSR

Страница 1: ...Manual WM 2520SSR WM 2520SSR LA WM 4520SSR WM 4520SSR LA WM 6520SSR WM 6520SSR LA www vinotemp com Read and save these instructions Vinotemp International Corp 732 South Racetrack Road Henderson NV 89...

Страница 2: ...cle installed by a qualified electrician DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE POWER CORD GROUNDING PRONG A separate adequately fused and grounded circuit should be available for this appliance Do...

Страница 3: ...2 Table of Contents Cellar Construction Guide 3 Features Specifications 4 Temperature Humidity 6 Care Guide 10 User Troubleshooting 11 Installer s Instructions 14 Electrical Wirings 26 Warranty 29...

Страница 4: ...temperature surrounding the cellar shall not exceed the temperature of the cellar by more than 25 F No cellar walls shall receive direct sun or strong wind Lighting shall be of low wattage with a tim...

Страница 5: ...evaporator units are designed for horizontal installation inside a rack or between two ceiling joists making them an ideal choice for small and medium wine cellars There are also multiple air inlet an...

Страница 6: ...d R19 exterior insulations Higher ambient temperatures or lower insulations will cause reducing capacity and the cellar temperature may not be maintained at 55 F The specifications are listed as follo...

Страница 7: ...ock the keypad SET To enter in the programming mode SET To return to the temperature display 2 Lock and unlock the keys To lock the keys press up down keys until POF is displayed to unlock the keys pr...

Страница 8: ...nstrument 2 Temperature Setting Set the temperature at 55 F for the optimum aging of wine On initial start up the time required to reach the desired temperature will vary depending on the quantity of...

Страница 9: ...e regulation differential 4 AC anti short cycle delay min 10 hidden Con compress on with probe faulty min 15 CoF compress off with probe faulty min 30 CF temperature unit F C F Fahrenheit rES display...

Страница 10: ...lative humidity Use a separate hygrometer to monitor the humidity 10 How to set alarm call 1 Speech notice will be sent to your phones when the cellar temperature is ALU higher or ALL lower than the s...

Страница 11: ...ng Clean the condenser coil regularly Coil may need to be cleaned at least every 6 months Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty 2 Condensate Remo...

Страница 12: ...ling unit turns on at 59 F of air temperature It may be higher than 59 F if it is in anti short cycle or defrost and turns off at 55 F of air temperature The average air temperature is 57 F and then t...

Страница 13: ...rt capacitor overload protector compressor c Call service 9 Compressor running but condenser fan not running a Fan blade stuck b Incorrect or loose wirings c Failed motors d Fan cycle control a Check...

Страница 14: ...cessive condensate b High humidity causing excessivecondensate c Drain restricted a Check for any air leak b Use drain line c Clean the drip tray and drain line 17 Condensateinside ducts a Drain line...

Страница 15: ...geration technician has properly installed the system Proper installation is critical Vinotemp can only warrant the quality of the components The installation and proper operation of the system must b...

Страница 16: ...252SFCR 32 x 29 3 16 x 11 1 8 x11 3 8 WM 252SCUR 18 x 14 x 12 220V 50Hz 4A 220V 50Hz 3A 10A 25 40 WM 2520SSR LA WM 252SFCR 32 x 29 3 16 x 11 1 8 x11 3 8 WM 252SCUR LA 18 x 14 x 12 220V 50Hz 4A 220V 50...

Страница 17: ...16 Fig 3 Temperature Controller 4 5 L X 4 5 W X 3 75H Fig 4 WM 252 652SFCR Evaporator Unit...

Страница 18: ...17 Fig 5 WM 252 452SCUR Condensing Unit Fig 6 WM 652SCUR Condensing Unit...

Страница 19: ...e air probe 3 Evaporator Unit Location 1 The WM 252 652SFCR evaporator units shall be installed for rack or joist mount with the supply air on the left front top or side and return air on the right fr...

Страница 20: ...e Suction Line Drain Line Recommended Initial Charge WM 2520SSR WM 2520SSR LA 75 FT 1 4 OD 3 8 OD 7 8 OD R134a 19 OZ WM 4520SSR WM 4520SSR LA 75 FT 1 4 OD 1 2 OD 7 8 OD R134a 26 OZ WM 6520SSR WM 6520S...

Страница 21: ...Back Position Normal operation manifold port is closed Front Position Storage operation liquid or suction line connection is closed Middle Position Installation operation all ports are open NOTE The r...

Страница 22: ...se the manifold high and low pressure valves Turn on the power to start the system 7 Check the following temperatures and pressures 8 Adjusting and Completing the Installation 1 Checking pressure cont...

Страница 23: ...installed at the bottom of the compressor and shall be turned on all the time The heater is self regulated B The condenser fan control The condenser fan control is installed at the high side It close...

Страница 24: ...d until it supplies the required CFM Fig 14 Fan Speed Control 3 The subcooling at the condensing unit shall be around 10 F The charge may be complete when there are no more bubbles forming in the liqu...

Страница 25: ...manifold 9 Pressure Superheat and Subcooling Readings CAUTION To read properly the service valves must be in the middlepositions Complaint Possible Causes 1 High suction pressure and low head pressure...

Страница 26: ...ng 15 low to normal suction pressure and high head pressure Normal to high superheat and high subcooling high evaporator load 7 Undercharge 8 Liquid line restricted after receiver solenoid valve restr...

Страница 27: ...he field wirings Use minimum 14 gauge wires for power lines If equipped with low ambient condition kit use low ambient temperature wiring diagrams A safety switch is always recommended for the condens...

Страница 28: ...27 Fig 17 WM 2520 4520SSR LA Electrical Wiring Diagram Fig 18 WM 6520SSR Electrical Wiring Diagram...

Страница 29: ...28 Fig 19 WM 6520SSR LA Electrical Wiring Diagram...

Страница 30: ...a particular purpose In no event shall VINOTEMP be responsible for any consequential damages what is so ever Any modification of VINOTEMP products shall void this warranty Service under Warranty This...

Страница 31: ...F USE OF THE UNIT LOSS OF TIME OR COMMERCIAL LOSS ANY OUTER DAMAGES WHETHER INCIDENTAL CONSEQUENTIAL OR OTHERWISE THIS WARRANTY IS EXCLUSIBE AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR INPLIED...

Отзывы: