- 5 -
CAUTION
If the condensing unit will operate below 50°F, install a low
ambient condition kit.
NOTE
The cooling capacity is determined under 55
°
F cellar
temperature, 75
°
F cellar ambient temperature and 90
°
F
condensing unit ambient temperature, with R13 interior and
R19 exterior insulations. Higher ambient temperatures or
lower insulations will cause reducing capacity and the cellar
temperature may not be maintained at 55
°
F.
The specifications are listed as follows:
Model No.
Capacity (Btu/h) / Airflow (CFM)
Max Cellar Size (cu ft)
WM-2500SSR
WM-2500SSR-LA
2500 / 220
250
WM-4500SSR
WM-4500SSR-LA
4500 / 335
1000
WM-6500SSR
WM-6500SSR-LA
6500 / 420
1500
NOTE
“LA” refers the unit equipped with a low ambient kit.
For further info, see Fig. 3~7.
Содержание WINE-MATE WM-2500SSR
Страница 2: ...1 Important Safety Information...
Страница 17: ...16 Fig 3 Temperature Controller 4 5 L X 4 5 W X 3 75H Fig 4 WM 25 65SFCR Evaporator Unit...
Страница 18: ...17 Fig 5 WM 250 450SCUR Condensing Unit Fig 6 WM 650SCUR Condensing Unit...
Страница 28: ...27 Fig 17 WM 2500 4500SSR LA Electrical Wiring Diagram Fig 18 WM 6500SSR Electrical Wiring Diagram...
Страница 29: ...28 Fig 19 WM 6500SSR LA Electrical Wiring Diagram...