- 5 -
Installation Instructions
NOTES:
•
Mounting brackets, screws, gaskets and other seal materials are not included.
•
Do not install any ducts onto the supply, return, intake and exhaust.
•
Because of potential safety hazards under a certain condition, we strongly
recommend against the use of an extension cord. However, if you still elect to
use an extension cord, it is absolutely necessary that it will be a UL LISTED
3-wire grounding type appliance extension cord having a 3-blade grounding
plug and a 3-slot receptacle that will plug into the appliance. The marked
rating of the extension cord shall be 220 V, 10 A.
1. Cabinet Location
•
Place the wine cabinet in a properly ventilated location. Otherwise, heat
exhausted by the cooling unit will build up and it will not operate properly.
•
The exhaust area must not be closed space and must be ventilated. The
ambient temperatures shall not be higher than 78°F for a WM-1520HTD unit
and 95°F for a WM-2520HTD unit or lower than 50 °F.
1) Rear Exhaust Location
•
Leave min 6 “clearance from the rear to the wall.
•
Leave min 12” clearance from the top to the ceiling.
•
Leave min 6” clearance from the left and right sides.
2) Front Exhaust Location
•
Leave min 6” clearance from the front if left and right sides unobstructed.
•
Or, leave min 36” clearance from the front if left and right sides obstructed
3) Top Exhaust Location
•
Leave min 12” from the top to the ceiling.
•
Leave min 2 “clearance from the rear to the wall.
•
Leave min 2” clearance from the left and right sides.
4) Side Exhaust Location
•
Leave min 6 “clearance from the left or right side to the wall.
•
Leave min 12” clearance from the top to the ceiling.
2. Cooling Unit Installation
•
The cooling unit produces cooling supplied into the cabinet, meanwhile it also
generates heat that must be exhausted outside the cabinet. So the cold-air
supply with return-air intake and hot-air exhaust with ambient-air side must be
separated and sealed. Foam tape gasket may be used to seal them. The
cooling unit must intake adequate fresh ambient-air to work properly. The
Содержание WINE-MATE WM-1520HTD
Страница 8: ... 7 Fig 2 1 CUTOUT AND HOLE DIMENSIONS Fig 2 2 REAR EXHAUST CUTOUT ...
Страница 9: ... 8 Fig 2 3 TOP EXHAUST CUTOUT Fig 2 4 MOUNTING SCREW INSERT Fig 2 5 GASKET AND SCREW INSERT ...
Страница 10: ... 9 Fig 2 6 TOP EXHAUST GASKET ...
Страница 11: ... 10 Fig 2 7 COOLING UNIT MOUNTED ...
Страница 12: ... 11 Fig 2 8 COOLING UNIT MOUNTED REAR EXHAUST Fig 2 9 COOLING UNIT MOUNTED TOP EXHAUST ...
Страница 21: ... 20 Wiring Diagram Fig 6 1 WIRING DIAGRAM ...
Страница 22: ... 21 Fig 6 2 WIRING DIAGRAM ALARM CALL ...