background image

 

 

Split Floor-Mounted Cooling System 

 

Operation Care Installation Manual 

 

WM-2500SSA WM-2500SSA-LA 
WM-4500SSA WM-4500SSA-LA 
WM-6500SSA WM-6500SSA-LA 
WM-8500SSA WM-8500SSA-LA 

WM-12000SSA WM-12000SSA-LA 

 

 

www.vinote

www.vinote

mp.com

mp.com

 

 

 

 

Read and save these instructions

Read and save these instructions

 

 

 

 

Vinotemp International Corp 
17631 S Susana Road Rancho Dominguez, CA 90221  
Tel: (800) 777-VINO Fax: (310) 886-3310 Email: [email protected] 

Содержание WINE-MATE WM-12000SSA

Страница 1: ...A LA WM 6500SSA WM 6500SSA LA WM 8500SSA WM 8500SSA LA WM 12000SSA WM 12000SSA LA www vinote www vinotemp com mp com Read and save these instructions Read and save these instructions Vinotemp Internat...

Страница 2: ...1 Important Safety Information...

Страница 3: ...2 Table of Contents Cellar Construction Guide 3 Features Specifications 4 Temperature Humidity 6 Care Guide 10 User Troubleshooting 11 Installer s Instructions 14 Electrical Wirings 26 Warranty 29...

Страница 4: ...temperature surrounding the cellar shall not exceed the temperature of the cellar by more than 25 F No cellar walls shall receive direct sun or strong wind Lighting shall be of low wattage with a tim...

Страница 5: ...for long term storage of wine like that in natural caves SSA evaporator units are designed for mounting on the floor making them an ideal choice for quick and convenient installation SSA cooling syste...

Страница 6: ...temperatures or lower insulations will cause reducing capacity and the cellar temperature may not be maintained at 55 F The specifications are listed as follows Model No Capacity Btu h Airflow CFM Max...

Страница 7: ...ock the keypad SET To enter in the programming mode SET To return to the temperature display 2 Lock and unlock the keys To lock the keys press up down keys until POF is displayed to unlock the keys pr...

Страница 8: ...nstrument 2 Temperature Setting Set the temperature at 55 F for the optimum aging of wine On initial start up the time required to reach the desired temperature will vary depending on the quantity of...

Страница 9: ...e regulation differential 4 AC anti short cycle delay min 10 hidden Con compress on with probe faulty min 15 CoF compress off with probe faulty min 30 CF temperature unit F C F Fahrenheit rES display...

Страница 10: ...ative humidity Use a separate hygrometer to monitor the humidity 10 How to set alarm call 1 Speech notice will be sent to your phones when the cellar temperature is ALU higher or ALL lower than the se...

Страница 11: ...ng Clean the condenser coil regularly Coil may need to be cleaned at least every 6 months Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty 2 Condensate Remo...

Страница 12: ...oling unit turns on at 59 F of air temperature It may be higher than 59 F if it is in anti short cycle or defrost and turns off at 55 F of air temperature The average air temperature is 57 F and then...

Страница 13: ...rt capacitor overload protector compressor c Call service 9 Compressor running but condenser fan not running a Fan blade stuck b Incorrect or loose wirings c Failed motors d Fan cycle control a Check...

Страница 14: ...cessive condensate b High humidity causing excessive condensate c Drain restricted a Check for any air leak b Use drain line c Clean the drip tray and drain line 17 Condensate inside ducts a Drain lin...

Страница 15: ...Installation of the system must be done in accordance with all state and local building and electrical codes The condensing unit and evaporator unit are connected by a liquid line and an insulated suc...

Страница 16: ...2A 115V 60HZ 6A 20A 42 60 WM 4500SSA LA WM 45SFCA 20 7 8 x 15 5 8 x 25 1 8 17 11 16 x 12 1 16 x 14 x 12 WM 450SCUR LA 18 x 14 x 12 115V 60HZ 2A 115V 60HZ 7A 20A 42 60 WM 6500SSA WM 65SFCA 20 7 8 x 15...

Страница 17: ...16 Fig 3 Temperature Controller 4 5 L X 4 5 W X 3 75H Fig 4 WM 25 120SFCA Evaporator Unit...

Страница 18: ...17 Fig 5 WM 250 450SCUR Condensing Unit Fig 6 WM 650 1203SCUR Condensing Unit...

Страница 19: ...l wires are necessary 18 gauge wires may be used to extend the air probe 3 Evaporator Unit Location 1 WM 25 120SFCA evaporator units shall be installed for floor mount with the supply air at the top a...

Страница 20: ...valent Line Set Liquid Line Suction Line Drain Line Recommended Initial Charge WM 2500SSA WM 2500SSA LA 75 FT 1 4 OD 3 8 OD 7 8 MPT R134a 19 OZ WM 4500SSA WM 4500SSA LA 75 FT 1 4 OD 1 2 OD 7 8 MPT R13...

Страница 21: ...ng Charging and Starting the System 1 Manifold High or Low Pressure Hose 2 Receiver Discharge or Compressor Suction Port 3 Liquid or Suction Line 4 Pressure Control BACK POSITION FRONT POSITION MIDDLE...

Страница 22: ...es to evacuate the system 4 Close the manifold high and low pressure valves and switch it to a charging scale 5 Open the manifold high and low pressure valves to charge the system using the recommende...

Страница 23: ...installed at the bottom of the compressor and shall be turned on all the time The heater is self regulated B The condenser fan control The condenser fan control is installed at the high side It close...

Страница 24: ...the condensing unit shall be around 10 F The charge may be complete when there are no more bubbles forming in the liquid indicator 4 The head pressure shall be 120 150 psig at 70 90 F condensing unit...

Страница 25: ...be in the middle positions Complaint Possible Causes 1 High suction pressure and low head pressure Zero superheat and zero subcooling 2 High suction pressure and low head pressure Low superheat and lo...

Страница 26: ...15 low to normal suction pressure and high head pressure Normal to high superheat and high subcooling 7 Undercharge 8 Liquid line restricted after receiver solenoid valve restricted 9 Suction line res...

Страница 27: ...he field wirings Use minimum 14 gauge wires for power lines If equipped with low ambient condition kit use low ambient temperature wiring diagrams A safety switch is always recommended for the condens...

Страница 28: ...27 Fig 17 WM 2500 4500SSA LA Electrical Wiring Diagram Fig 18 WM 6500 12000SSA Electrical Wiring Diagram...

Страница 29: ...28 Fig 19 WM 6500 12000SSA LA Electrical Wiring Diagram...

Страница 30: ...and is in lieu of all other warranties express or implied including any of fitness for a particular purpose In no event shall VINOTEMP be responsible for any consequential damages what is so ever Any...

Страница 31: ...NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE While great effort has been made to provide accurate guidelines VINOTEMP cannot warrant its units to properly...