Thank you for choosing a Vinotemp cooling unit. 

 
Please enter the complete model and serial numbers in the space provided: 

 
Model_________________________________________________________ 
Serial No.______________________________________________________ 

 
Attach your purchase receipt to this owner’s manual. 
 
 

1.  Limited Warranty 

         
 
VINOTEMP  warrants  its  products,  parts  only,  to  be  free  from  defects  due  to 
workmanship or materials under normal use and service for twelve months after 
the  initial  sale.  If  the  product  is  defective  due  to  workmanship  or  materials,  is 
removed within twelve months of the initial sale and is returned to VINOTEMP, in 
the original shipping carton, shipping prepaid, VINOTEMP will at its option, repair 
or replace the product free of charge.  
 
This warranty constitutes the entire warranty of the VINOTEMP with respect to its 
products and is in lieu of all other warranties, express or implied, including any of 
fitness for a particular purpose. In no event shall VINOTEMP be responsible for 
any  consequential  damages  what  is  so  ever.  Any  modification  of  VINOTEMP 
products shall void this warranty. 
 
 

Service under Warranty 

 
This  service  is  provided  to  customers  within  the  continental  UNITED  STATES 
only.  VINOTEMP  cooling  units  are  warranted  to  produce  the  stated  number  of 
BTU/H.  While  every  effort  has  been  made  to  provide  accurate  guidelines, 
VINOTEMP can not warranty its units to cool a particular enclosure. 
             
In case of failure, VINOTEMP cooling units must be repaired by the factory or its 
authorized  agent.  Repairs  or  modifications  made  by  anyone  else  will  void  the 
warranty. 
             
Shall  a  VINOTEMP  cooling  unit  fail,  contact  the  dealer  for  instructions,  do  not 
return  the  unit  to  the  factory  without  authorization  from  VINOTEMP.  If  the  unit 
requires  repair,  re-pack  it  in  the  original  shipping  carton  and  return  it  to  the 
factory, shipping prepaid. VINOTEMP will not accept COD shipments. If the unit 
is  determined  to  be  faulty  and  is  within  the  twelve  month  warranty  period 

Содержание Wine-Mate 2520SSW-LA

Страница 1: ...A WM 4520SSW 4520SSW LA w ww ww w v vi in no ot te em mp p c co om m R Re ea ad d a an nd d s sa av ve e t th he es se e i in ns st tr ru uc ct ti io on ns s Vinotemp International Corp 17631 S Susana...

Страница 2: ...1 Important Safety Information...

Страница 3: ...2 Table of Contents Cellar Construction Guide 3 Features Specifications 4 Temperature Humidity 6 Care Guide 10 User Troubleshooting 11 Installer s Instructions 14 Electrical Wirings 25 Warranty 27...

Страница 4: ...temperature surrounding the cellar shall not exceed the temperature of the cellar by more than 25 F No cellar walls shall receive direct sun or strong wind Lighting shall be of low wattage with a tim...

Страница 5: ...wine like that in natural caves SSW evaporator units can be installed inside a wine rack or between two wall studs making them an idea choice for wine cabinets or small wine rooms as built in install...

Страница 6: ...with R13 interior and R19 exterior insulations Higher ambient temperatures or lower insulations will cause reducing capacity and the cellar temperature may not be maintained at 55 F The specification...

Страница 7: ...ock the keypad SET To enter in the programming mode SET To return to the temperature display 2 Lock and unlock the keys To lock the keys press up down keys until POF is displayed to unlock the keys pr...

Страница 8: ...nstrument 2 Temperature Setting Set the temperature at 55 F for the optimum aging of wine On initial start up the time required to reach the desired temperature will vary depending on the quantity of...

Страница 9: ...e regulation differential 4 AC anti short cycle delay min 10 hidden Con compress on with probe faulty min 15 CoF compress off with probe faulty min 30 CF temperature unit F C F Fahrenheit rES display...

Страница 10: ...ative humidity Use a separate hygrometer to monitor the humidity 10 How to set alarm call 1 Speech notice will be sent to your phones when the cellar temperature is ALU higher or ALL lower than the se...

Страница 11: ...ng Clean the condenser coil regularly Coil may need to be cleaned at least every 6 months Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty 2 Condensate Remo...

Страница 12: ...the wine temperature is around 57 0 5 F The air is light enough to change so quickly that it maintains relatively constant average temperature that would prevent wine bottle temperature from fluctuati...

Страница 13: ...Post compressor fan running mode for humidity modulation a Reset FON 12 Evaporator fan running but condensing unit not running a Incorrect or loose wirings b Failed components c Low refrigerant a Che...

Страница 14: ...difier c Increase air flow or raise temperature setting 19 Circuit tripping a Incorrect fuse or breaker b Incorrect wirings c Failed components a Check for proper fuse or breaker b Check for wirings a...

Страница 15: ...Installation of the system must be done in accordance with all state and local building and electrical codes The condensing unit and evaporator unit are connected by a liquid line and an insulated suc...

Страница 16: ...x H Electrical Rating Evap Unit Cond Unit Min Circuit Ampacity Weight lb Evap Unit Cond Unit WM 2520SSW WM 252SFCW 16 x 5 1 2 x 36 x 34 WM 252SCUR 18 x 14 x 12 220V 50Hz 4A 220V 50Hz 3A 10A 30 40 WM...

Страница 17: ...ir return area 3 Evaporator Unit Location 1 The WM252 452SFCW evaporator units shall be installed for wall mount with the air supply on the top side and air return on the bottom side It can be install...

Страница 18: ...higher than 110 F or lower than 50 F 3 Leave minimum 5 ft clearance for the air exhaust side and leave minimum 1 foot clearance for the ambient air intake side 5 Refrigeration Piping and Leak Testing...

Страница 19: ...or If the elevation difference is more than 10 ft use both inverted U trap and suction accumulator 4 If the condensing unit is located more than 10 ft above the evaporator unit use U trap to aid oil r...

Страница 20: ...e compressor after the condensing unit has been powered for 12 hours 1 Turn both discharge and suction valves in the middle positions 2 Connect the manifold high or low pressure hose to the discharge...

Страница 21: ...ressure setting Cut out 5 psig Cut in 25 psig Differential 20 psig Head pressure setting Cut out 230 psig Cut in 150 psig Differential 80 psig It is necessary to adjust the setting in the field to rea...

Страница 22: ...ng Cut in 170 psig Cut out 110 psig Differential 60 psig Fig 11 Condenser Fan Cycle Control 2 A fan speed control may be used to adjust the air flow to achieve the specified CFM The fan will run from...

Страница 23: ...first to see if the refrigerant charge is sufficient If the charge is not sufficient add more refrigerant Liquid must always be charged into the hide side when the compressor runs If the charge is goo...

Страница 24: ...High superheat and normal to high subcooling 12 Low suction pressure and normal head pressure High superheat and normal subcooling 13 Low suction pressure and high head pressure High superheat and hi...

Страница 25: ...d components 4 Low pressure switch shutting down the system 5 high pressure switch shutting down the system 1 Check for proper voltage 2 Check all wirings and connections 3 Check start relay start cap...

Страница 26: ...he field wirings Use minimum 14 gauge wires for power lines If equipped with low ambient condition kit use low ambient temperature wiring diagrams A safety switch is always recommended for the condens...

Страница 27: ...26 Fig 14 WM 2520 4520SSW LA Electrical Wiring Diagram...