![Vinopro BU-22 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/vinopro/bu-22/bu-22_service-manual_1028044010.webp)
17
●
If fault Code ”
LL
” shown on display window, it indicates open circuit happened, pls.
replace the Sensor with new one.
(Figure 19 & Figure 19-1)
●
if fault Code ”
HH
” shown on display window, it indicates short circuit happened , pls.
replace the Sensor with new one.
(Figure 19 & Figure 19-1)
■
Temp. Sensor Replace .
(Figure 19 & Figure 19-1)
Step 1: Remove all Shelves
(Figure 1 & Figure 7)
;
Step 2: Remove Baffle Board and Control Box
(Figure 5 & Figure 9)
;
Step3: Unplug all Terminal of Fan and Temp. Senor
(Figure 5 & Figure 9)
;
Step 3 : Unscrew Screws of Temp. Senor, Remove Temp. Senor and Replace it with new one.
(Figure 19 & Figure 19-1)
1. For BU-22
T1
(
Temp.Sensor)
Terminal
For 7 Bottles
18
2. For BU-58
■
Display Error of LED Light
It is caused by Control PCB fault, remove and replace it with new one.
(Figure 20 & Figure 21)
T1
(
Temp.Sensor)
For 19 Bottles
Terminals
Screws (2pcs)
Control PCB
Bracket
Control PCB
Phillips
Screwdriver