Vingtor Stentofon TCIV-2SIP Скачать руководство пользователя страница 2

On-Wall Surface Mounting

2.1  On-Wall Surface Mount Backbox - TA-1

2.2  On-Wall Surface Mounting Procedure

1.  Mount the backbox onto the wall
2.  Fit the gasket onto the backbox with the ridged side facing down

 

Plug the Ethernet cable into the RJ-45 port on the station

3.  Mount the station onto the backbox with the M5 fasteners provided applying 1.5 Nm 

torque

76 mm

150 mm

D6.5 mm

25 mm

120 mm

Mounting holes are to be drilled 

as shown.
Max. recommended screw 

diameter: ISO M6 or ANSI 1/4".

Screw length must be greater 

than 25 mm or 1".

 

A4 stainless steel socket head 

screws/bolts are recommended.

Max. recommended screw

head diameter: 9.5 mm or 3/8".

3”

5.90”

4.72”

1”

0.25”

D

Mounting Hole

Mounting Hole

Mounting Hole

Mounting Hole

Optional washers for extra protection

against corrosive effects between

surfaces are provided. 

They should be placed at the bottom 

of the 4 mounting holes.

Grommets and an M20 cable gland 

are provided.

cable holes

M20

M16

Surface

Mount 

Back Box

Gasket

Turbine

Station

1

2

3

Microphone

Washers

Camera

Lens

 

L

The Gasket MUST be mounted to 

seal the station!

 

L

Ensure the station is mounted verti-

cally with the microphone aperture 

facing down.

 

L

Ensure there is enough clearance 

under the station so that the micro-

phone aperture is NOT smothered.

 

L

Place the washers at the bottom of 

the 4 mounting holes on the back 

box.

 

L

Use the grommets and M20 cable 

gland provided for the cable holes 

on the back box.