Gasifying boilers VIGAS
Boiler assembly must be done by specialists of assembly firms.
Boiler need not be placed on a firm base.
Minimum temperature of reversible water at boiler inlet is 60
0
C.
Boiler room must be ventilated permanently through the opening of min. diameter 0,025
m
2
. The diameter for air inlet and outlet must equal approximately.
Boiler must be installed in the surrounding that is common, basic in accordance with the
standard, STN 33 2000-3.
Work and health safety regulations must be followed in accordance with current
instruction requirements, UBP SR No. 718/2002 Coll. and seq.
Z
h
ľ
adiska požiarno-technické vlastnosti hmôt v
blízkosti kotla musia by
ť
splnené
požiadavky normy STN 73 0823:1983/z1 - Stupe
ň
hor
ľ
avosti stavebných hmôt.
18.2 Safety regulations for control and maintenance of VIGAS boiler electric
equipment
The boiler operator must follow relevant regulations and standards, as well as the following
principles:
If boiler is in operation, none of the following may be done with electric equipment:
o
uncover electronic equipment, e.g. boiler electronics, fan, thermostat,
o
to exchange fuse,
o
to repair damaged cable insulation etc.
Maintenance and repairs of boiler with uncovered electric equipment may only be done by
persons authorized to do so according to 74/1996 Coll.
Before uncovering boiler or any electric equipment connected to boiler, it is necessary to
disconnect any mains /unplug/. You can only plug in after placing covers on original
places.
If there is any defect of electric equipment or boiler installation is damaged it is important: - do
not touch any part of boiler
o
disconnect boiler from mains /unplug/.
o
to call an authorized service technician that will correct defect.
Apart from common maintenance of boiler, it is strictly forbidden:
to manipulate electric equipment and boiler installation if plugged in,
to touch damaged electric equipment and boiler installation, mainly damage cable insulation ,
etc.,
o
to operate boiler if uncovered,,
o
to operate boiler with defective electric equipment or defective boiler installation,
o
to repair damaged boiler electric parts by persons unauthorized by the producer