![Vimar ELVOX TVCC 46535.550E Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/vimar/elvox-tvcc-46535-550e/elvox-tvcc-46535-550e_installation-and-operation-manual_1027579022.webp)
20
46535.550E
EN
4.3.2 - IR Display
<IR DISPLAY>
WORKING MODE
TESTING TIME
OUTPUT POWER
ILLUMINATION ON
AMBIENT LIGHT
IR SWITCH ZOOM
EXIT
AUTO
08S
100%
03
09
06
WORKING MODE:
Working mode has auto, black/white, color selectable. Default is auto.
TESTING TIME:
On IR auto working mode and the programmed time, the IR will execute the programmed action, eg. Switch from day to night or from night
to day. The detection time is from 2s to 15s selectable.
OUTPUT POWER:
IR output consumption has 40%,60%,80%,100% selectable.
ILLUMINATION ON:
Illumination on is 1 to15 grade selectable and default is 3. On the auto IR working mode, if the illumination on level is less than the
ambient light, the picture will change to color, the IR illumination will turn off automatically. If the illumination on level is more than the ambient light, the
picture will change to black, the IR illumination will turn on automatically.
AMBIENT LIGHT:
Ambient light is a system data. User can not change it manually. It changes according to the environment all the time. The data will
refresh every time when user enter the OSD. It is from 0 to 50 grade.
IR SWITCH ZOOM:
IR swith zoom is 1-10 grade selectable and default is 5 zoom.User can set it according to the environment.
4.3.3 - Guard Tours
<GUARD TOURS>
<GUARD TOUR 01>
GUARD TOUR 01
<SETTING>
INIT
DELETE
EXIT
ID PUNTO DURATA (S) VELOCITÀ
1 01 06 64
2 02 06 64
3 03 06 64
4 04 06 64
5 05 06 64
6 06 06 64
7 07 06 64
8 08 06 64
GUARD TOUR:
Total 8 guard tours selectable: 01, 02-08.
SETTING:
Each guard tour includes max 16 presets. The number of the preset is from 0-16. 0 is not valid, dwell time is 1 to 60s selectable. Speed is 1 to
64 grade selectable.
INIT:
After init., preset point, dwell time, speed will resume to default setting.
RUNNING:
Running the present guard tour.
DELETE :
Delete the guard tour set. After deleting, the present preset points all display as 0. While the exact preset point information doesn’t be deleted.
So it is convenient for user to select the preset point needing to be guarded tour.
4.3.4 - A-B Scan
<A-B SCAN>
<A-B SCAN>
PRESET A
PRESET B
SCAN SPEED
DWELL TIME
RUNNING
DELETE
EXIT
20
06 S
RUNNING.....
PRESET 1: SAVE
PRESET 2: BACK
Fig. 4.3.4.1
Fig. 4.3.4.2
SCAN SPEED:
A-B scan speed is 1 to 64 grade selectable.
DWELL TIME:
Dwell time between A to B is 2s to 60s selectable.
RUNNING:
Running the A-B scan. Check Fig. 4.3.4.2
DELETE:
After deleted, the preset points display as 0. While the exact preset point information doesn’t be deleted. So it is convenient for user to select
the preset point needing to be scanned. Speed and dwell time will reset as default setting.
Содержание ELVOX TVCC 46535.550E
Страница 26: ... 24 46535 550E IT ...
Страница 27: ... 25 46535 550E IT ...
Страница 28: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com 49401403A0 00 1905 ...