17
HIDDY
Electrical wiring harnesses:
take the actuator cable to the watertight junction box (cable length 2 metres) and do the wiring according to the diagram:
Wire colour
Description
White
Encoder signal
Blue
Encoder supply voltage negative (GND)
Brown
Encoder supply voltage positive (+12 Vdc)
Red
Motor supply voltage
Black
Motor supply voltage
User Manual
Manual unlocking:
In the event of mains power failure, the back-up battery ensures the operation of the automatic gate system for a limited period. If the
battery is discharged or not installed, manually unlock the actuator using the unlocking lever.
1. Remove the plastic cap
2. Insert the lever and rotate it by 90° until the gate leaf is freed
3. The gate leaf is unlocked and opens with a slight pressure.
4. Remove the lever and put the cap back on.
5. Repeat operations 1 to 4 for the second gate leaf, if present.
- To return to automatic operation:
1. Remove the plastic cap
2. Insert the lever and rotate it 90° anticlockwise
3. Move the gate leaf into the coupling position and turn the lever 90° clockwise
4. Remove the lever and put the cap back on.
5. Repeat operations 1 to 4 for the second gate leaf, if present.
The electrical wiring between the control unit and the actuator must not exceed 15 metres
EN