14
3.4.2 Index of Menu
PROTOCOL
PELCO-D
LANGUAGE
ENGLISH
SOUND
OFF
ADDRESS
000
BAUD RATE
2400
PELCO-D 2400 000
FOCUS+
The above menus are displayed in the second line on LCD. Only one menu is displayed at one time. The display mode
is as below (e.g communication address):
LCD
MENU
ADDRESS
000
Menu Setting Range:
- PROTOCOL: PELCO-P/ PELCO-D / SAMSUNG / YAAN / SAE
- LANGUAGE: ENGLISH
- SOUND: ON/OFF
- ADDRESS: 000 ~ 255
- BAUD RATE: 1200/2400/4800/9600/19200 BPS
3.5 Menu Operation
When joystick and keys are operated at the same time, joystick operation is preferred.
Rotating the joystick to any direction can exit the present setting page (except on menu page).
When setting parameters in menu, pressing [Enter] can make the setting effective. The key [Enter] just store the latest
changed parameters of menu.
For example, if you change protocal, address and baud rate in order, then press [Enter]. Only baud rate is changed
successfully.
When there is nothing in the second line on LCD as Fig 3.5.1, number keys [2], [8], [4], [6] can be used as up, down, left
and right keys to control PTZ or dome camera left and right rotation as the function of joystick. But the rotation speed
is the fastest and no grades to select, shown as 3.5.2 (e.g key [2]).
PELCO-D 2400 000
PT->UP
PELCO-D 2400 000
Fig 3.5.1
Fig 3.5.2
After entering menu, joystick has no function to control PTZ or dome camera. It can only be used as up or down to flip
the menu page and left or right to change the parameters of menu. Number keys [0], [1], [3], [5], [7], [9] are invalid. [2],
[8], [4], [6] are used as up, down, left and right keys. They are not used as number keys at this time. Their functions
are just to flip the menu page but not to control PTZ or dome camera’s up, down, left or right rotation. Only after exiting
menu and when there is nothing in the second line on LCD, they can control dome camera’s up, down, left and right
rotation.
EN