EN
Local configuration
Using the device's four push buttons, you can configure
certain operating parameters (lock time, conversation time,
audio level). It is also possible to perform the ordering pro-
cedure for the push button modules (art. 41010) which may
be connected to the audio video electronic module. During
configuration, the four white LEDs located at the push but
-
tons provide appropriate feedback.
If the display module is connected (art. 41018), it is possible
to use its interface (screen and three buttons) to perform the
same configurations.
Note: To make the electronic module operative, you must
complete the configuration using the configuration software
(see next section).
Configuration input
The procedure is activated, from the state of rest of the
speech unit, by pressing and holding the
push button
for 5 s. After this time the speech unit will emit a tone. Re-
lease the
push button and, within 30 s, press the se
-
quence of push buttons forming the password. The timeout
is renewed each time the button is pressed, so there are 30
s from the tone after which the speech unit goes back to rest.
By default the password is:
Activation is confirmed by a tone.
Use the 4 push buttons to navigate through the choice of
the item to configure. The button function and numbering
is as follows:
PREVIOUS
: to return to the previous
sequence.
NEXT
: to move on to the next sequence.
DEL
: to exit the configuration menu or a
configuration editing phase, cancelling the
selected one.
OK
: to go from the sequence menu to
configuration editing or to confirm the change
to a configuration.
The LEDs indicate the currently selected configuration item
(parameter), as in the following table:
LED configuration
Meaning (Parameter)
Selecting order of push button
modules
Lock time
Conversation time
Audio level
Restart
Pressing the
push button (DEL) at this level sets it
back to rest.
Press
(OK) to enter the specific configuration.
1. Selecting order of push button modules
By confirming with
(OK) you select how any modules
Art. 41010 connected to the speech unit are ordered. The 4
push buttons on the standard module are automatically put
in first place.
If the procedure can begin, the 4 LEDs on the standard mod-
ule will start blinking slowly, otherwise only one will turn on
to indicate an error code. By pressing
(DEL) and then
again
OK you can try entering the ordering procedure
again.
Once started, you can cancel the procedure by pressing
(DEL).
The LEDs of all the modules Art. 41010 will begin to flash.
The number of flashing LEDs for each module indicates their
current position, so that module number 1 will have only one
13
41006
Содержание ELVOX 41006
Страница 52: ...led Mini USB LED RJ45 CA NO NC SELV CA S S IP CA S S CA RJ45 52 41006 EL...
Страница 53: ...41010 LED 41018 interface 5 30 30 4 OK LED LED OK 1 OK 41010 4 4 OK led 41010 led 53 41006 EL...
Страница 55: ...1 2 25 5 5 50 4 LED 4 LED 75 100 Video Door IP Manager www vimar com LAN LAN 41010 5 55 41006 EL...
Страница 58: ...58 41006...
Страница 59: ...59 41006...
Страница 60: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com 49400683A0 00 1709...