When the sequence is active and you fall into the menu Fading-Show, the screen
becomes the following:
• Tapping the
icon will stop the sequence of Faing-Show set.
Example for setting the Fading-Show with 4 colors.
- With the
icon set the desired 4 colors; with
remove the 2 colors
that you want to include in the sequence.
- With
and
set the
Persistance
and
Transition
(for example, 2 min
and 15 s respectively).
- Tapping
confirms the settings you have made.
- Tapping
to activate the sequence Fading-Show just set.
In the case considered the color remains fixed for 2 minutes then if will start to
change up to the next color within 15 seconds.
Dimmer feature when it is combined with the “Brightness Sensor”
If the system is fitted with a brightness sensor combined with art. 01467, you can
keep the brightness in a room automatically constant according to the value read
by the sensor and a brightness setpoint that is set automatically with each adjust-
ment on the dimmer.
The function of keeping the brightness constant can be switched on/off at any time
by tapping
; in this case the controls become the same as for any other
dimmered lighting point.
This function then allows obtaining energy savings as natural light is used, as long
as possible, instead of artificial light for lighting the room.
On the touchscreen, the dimmer combined with the brightness sensor can be
added to any room screen and the view is similar to the following:
•
THERMOSTAT AND TEMPERATURE PROBE
In the touchscreen, at the graphical user interface level, the thermostat and the
temperature probe behave in a similar way; it will then display:
• Current temperature.
• Temperature measured by the external sensor connected to the thermostat input
(if fitted).
• Relative humidity, measured by the electronic humidity sensor (if fitted).
• Speed of fan coil
(if fitted).
• Current setpoint.
• Output status (on, off and, when present, with boost)
.
• Alarm symbol of an external probe used as a screed alarm in an underfloor
system
.
With the touchscreen you can set:
• Seasonal mode SUMMER – NEUTRAL ZONE – WINTER.
• Operating mode.
• Temperature setpoint.
• Fan coil speed (1-2-3 AUTO or setting on a proportional value, in steps of 10%,
between 0 and 100% or AUTO)
.
•
OTHER TYPES OF ADJUSTMENTS
The touchscreen lets you make other types of proportional adjustments that are not
necessarily related to the lighting; a viewing example can be as follows:
If the actuator is OFF, the display will show:
.
If there is a fault on the output that you are adjusting, the associated control will
display a specific warning instead of the adjustment value:
If the system includes the device with 3 analogue inputs 01467 which is connected
to a dedicated sensor, the room control screens may display one or more instanta-
neous values of different variables measured by the sensor.
The variables that can be viewed, which can be brightness, wind speed, baromet-
ric pressure, relative humidity, air quality, air flow, voltage, electric current, power,
amount of rainfall and temperature, are shown as follows:
If the displayed variable is relative humidity and when envisaged by the system,
you can set a setpoint on exceeding which a special alarm will be displayed, and
activated when needed.
On the previous screen, notice that the ON/OFF output status indicator linked to it
may be absent if the humidity control is disabled on the setpoint adjustment screen.
Tapping
displays the screen for setpoint adjustment (minimum value 20%
- maximum value 80%) and for switching the output control on/off:
•
CLIMATE CONTROLLER
If there is one or more climate controllers in the system and the installer has
configured their command/control in the touch screen, the device will display the
following operating options:
- Fixed mode (with the possible setpoint control).
- Modulating mode.
If there is a malfunction of the system, or damage to the probes connected to the
climate controller, the touch screen will display the icon
.
ON normal
On in the
adjustment phase
Adjustment OFF
Viewing only