![Vimar By-alarm 01717 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/vimar/by-alarm-01717/by-alarm-01717_quick-start-manual_1027143003.webp)
Viale Vicenza, 14
36063 Marostica VI - Italy
www.vimar.com
49400895C0 01 1705
By-alarm
01717-01717.120
FRONT VIEW AND BOARD
1.
2.
F3,15A
F1
250V
BC
TI
12V–
MC
F3,15A
F2
250V
F3,15A
F3
250V
18V–
D
A
B
C
By-alarm additional power supply unit 50/60 Hz 1.5 A, metal enclosure
with battery compartment, surface mounting.
TECHNICAL CHARACTERISTICS
• Power supply for
art. 01717
:
230 V~
(+10% / -15%) 50 Hz
• Power supply for
art. 01717.120
:
120 V~
(+10% / -10%) 60 Hz
• Stabilized voltage: 13.8 Vdc nominal (± 2%)
• Rated current: 1.5 A total
• Ripple at 230 V~ -15%: 10 mV at maximum load
• Ripple at 120 V~ -10%: 350 mV at maximum load
• Autotest: dynamic and programmable
• Operating temperature: -10..+40 °C (indoor use)
• Dimensions: 345x435x125 mm
• Degree of safety 2 (EN 50131-6)
• Ambient class II (EN 50131-6)
BATTERIES
Sealed 12 V lead batteries must be used with flammability class UL94-HB; the cables
for connecting the battery are designed for Faston connectors.
For the screw connection, the Faston connector is to be cut and eyelet terminals
must be fixed to the ends of the cables.
CAUTION: Danger of explosion if the battery is replaced with one of the wrong
type.
OPERATING CURRENT
The operating current for the external loads depends on the characteristics of the
battery for self-powering the control panel according to the table alongside.
Current available with
internal battery of
7.2 Ah
Current available for
self-powering the system
1200 mA
Current for recharging battery
277 mA
Current available with
internal battery of
18 Ah
Current available for
self-powering the system
650 mA
Current for recharging battery
847 mA
INSTALLATION RULES
Installation should be carried out in compliance with the current regulations regarding
the installation of electrical equipment in the country where the products are installed.
Cable entry
The mains power supply cables must be inserted using the hole nearest to the 230
V~ connection terminal block and to which they must be fixed without having been
consolidated by soldering; they must also have been inserted in advance into an
additional sheath in order to ensure double insulation.
There must be an over-current circuit breaker with a high breaking capacity (1500 A)
upstream of the connection to the control panel.
If other holes are used for routing the cables, it is necessary to use cable outlets or
junction fittings for pipe or sheath constructed with materials of flammability class
HB or higher.
Earth connection
For the earth connection you need to use the specific terminal located near the trans-
former by the connection of its mains power supply; the metal cover should also be
earthed, using the Faston terminal.
Caution
: correct earthing protects the control panel and all its devices from faults
caused by electrical and atmospheric discharges and in particular ensures the integ-
rity of the telecommunications network.
Fuses
F1
: F 3.15A - 250V, located directly on the mains voltage terminals directly at the
input of the transformer, it protects the low alternating voltage input.
F2
: T 3.15A - 250V, provides protection on the power supply positive output.
F3
: T 3.15A - 250V, provides protection against polarity reversal of the battery.
REGULATORY COMPLIANCE
EN 50131-6.
LV directive. EMC directive.
Standards EN 60950-1, EN 50130-4, EN 61000-6-3.
WEEE - User information
The crossed bin symbol on the appliance or on its packaging indicates
that the product at the end of its life must be collected separately from
other waste. The user must therefore hand the equipment at the end of
its life cycle over to the appropriate municipal centres for the differen-
tiated collection of electrical and electronic waste. As an alternative to
independent management, you can deliver the equipment you want to
dispose of to the dealer when purchasing a new appliance of an equiva-
lent type. You can also deliver electronic products to be disposed of that
are smaller than 25 cm for free, with no obligation to purchase, to elec-
tronics retailers with a sales area of at least 400 m
2
. Proper sorted waste
collection for subsequent recycling, processing and environmentally
conscious disposal of the old equipment helps to prevent any possible
negative impact on the environment and human health while promoting
the practice of reusing and/or recycling materials used in manufacture.
A
: Terminals for connecting the transformer located under the printed circuit board.
B:
Terminals for connecting the battery.
C
: Ter - for powering devices.
D
: Terminals for connecting 8-input expansion module 01704.
WARNING:
Dispose of batteries in the specific
differentiated collection bins.