Vimar 16584 Скачать руководство пользователя страница 1

Libretto uso e manutenzione

Operating and maintenance

instruction

Guide à l'usage et à l'entretien

Via IV Novembre, 32 - 36063 Marostica VI
Tel. +39.0424.488.100 - Fax +39.0424.488.188
http://www.vimar.it

800-862307

Numero Verde

16584 - 16584.B
16585 - 16585.B

08484
08485

8000

Orologio programmatore elettronico 

giornaliero/settimanale

Electronic time-delay switch

24 hour/7 day program

Interrupteur horaire programmable 

électronique

journalier/hebdomadaire

0005     0B      90716584

Содержание 16584

Страница 1: ...ica VI Tel 39 0424 488 100 Fax 39 0424 488 188 http www vimar it 800 862307 Numero Verde 16584 16584 B 16585 16585 B 08484 08485 8000 Orologio programmatore elettronico giornaliero settimanale Electronic time delay switch 24 hour 7 day program Interrupteur horaire programmable électronique journalier hebdomadaire 0005 0B 90716584 ...

Страница 2: ...ogrammata La programmazione si sviluppa sia a livello giornaliero sia a livello settimanale vedi Caratterisitche Sono pertanto particolarmente utili per impianti di riscaldamento e condizionamento di qualsiasi tipo impianti di irrigazione impianti di illuminazione insegne luminose ecc La versione 1 CANALE 16584 16584 B 08484 presenta un relé di uscita con contatto in commutazione senza potenziale ...

Страница 3: ...ervento 1 s Temperatura di esercizio da 10 C a 55 C Classe di isolamento II Visualizzazione dati a mezzo display a cristalli liquidi di dimensione 37x21 mm Dati visualizzati giorno ore minuti indicazione ora legale posizione contatti I e 0 indicazione posizione permanente P del contatto o dei contatti programma completo inserito in giorni ore minuti con rispettiva posizione dei contatti indicazion...

Страница 4: ...manente della posizione del contatto indicata dalla lettera P sul display il programma viene ristabilito al successivo comando manuale Contatti di uscita 16 A 250 V cos f 1 8 A 250 V cos f 0 7 16584 08484 contatto a due vie commutazione senza potenziale morsetti 4 5 6 secondo lo schema riportato sul pezzo 16585 08485 due contatti a programmazione indipendente a una via interruzione senza potenzial...

Страница 5: ...olazione valori Comando manovra manuale Cancellazione totale memoria Conferma e verifica programmi impostati Selettore ore minuti giorni Impostazione ora legale P 0 I P 0 I TIME PROG 2 1 3 4 5 6 7 S Indicazione ora Indicazione programma Indicazione del giorno o di blocchi di giorni Contatto permanente Indicazione ora legale Contatto ON chiuso Contatto OFF aperto 4 90716584 11 05 2000 14 19 Pagina ...

Страница 6: ...remere il tasto MODE per l impostazione dell ora e del giorno attuale sul display appare la scritta TIME 3 Premere il tasto 1h per l impostazione dell ora legale comparirà il simbolo S che indica ora legale 4 Premere il tasto SELECT inizia a lampeggiare l indicatore delle ore 0 0 1 TIME 1 TIME 1 S TIME 1 S 5 90716584 11 05 2000 14 19 Pagina 5 ...

Страница 7: ...re il tasto SELECT inizia a lampeggiare l indicatore dei minuti 7 Premere il tasto ADJUST finchè l indicatore dei minuti arriva a 58 tenendo premuto il tasto oltre 1 s aumenta la velocità di visualizzazione 8 Premere il tasto SELECT inizia a lampeggiare l indicatore dei giorni TIME 1 S TIME 1 S TIME 1 S TIME 1 S 6 90716584 11 05 2000 14 19 Pagina 6 ...

Страница 8: ...nchè l indicatore dei giorni arriva a 3 mercoledì 10 Premere il tasto ENTER si confermano i valori impostati ottenendo così la messa in servizio all ora e al giorno desiderati TIME S 3 S 3 0 0 7 90716584 11 05 2000 14 19 Pagina 7 ...

Страница 9: ...icevere l impostazione dell ora e del giorno o blocco di giorni dell intervento di ON sul canale A 3 Premere il tasto SELECT inizia a lampeggiare l indicatore delle ore ripetere le operazioni della messa in servizio dal punto 5 al punto 10 compreso Mentre si sta regolando il giorno se si continua a premere il tasto ADJUST si ottiene la visualizzazione dei blocchi di giorni vedere schema pagina seg...

Страница 10: ...mere il tasto MODE per ritornare alla visualizzazione dell ora attuale 2 2 1 1 3 3 4 4 5 5 6 6 7 2 1 3 4 5 6 2 1 3 4 5 2 1 3 4 5 6 7 6 7 7 Lunedi Il comando inserito avviene BLOCCHI DI GIORNI Ogni giorno della settimana Dal lunedi al sabato Dal lunedi al venerdi Dal lunedi al giovedi Dal venerdi alla domenica Solo sabato e domenica Martedi Mercoledi Giovedi Venerdi Sabato Domenica I PROG 1 I 3 S 9...

Страница 11: ...del canale A si preme nuovamente il tasto MODE il display mostrerà la scritta PROG i simboli I e 0 del contatto del canale B e la memoria ancora disponibile il numero totale di interventi dei due canali è sempre 30 3 Programmare gli interventi desiderati ripetendo le operazioni descritte dal punto 2 al punto 5 compresi della programmazione orologio ad 1 canale PROG 0 I 10 90716584 11 05 2000 14 19...

Страница 12: ... ancora disponibile 2 Premendo sul tasto ENTER si visualizzano uno dopo l altro tutti gli interventi programmati 3 In questo modo l orologio programmatore indica il termine del programma inserito 4 Premere il tasto MODE ricompare l indicazione dell ora attuale 0 I PROG I PROG 3 I PROG 1 0 0 3 S 11 90716584 11 05 2000 14 19 Pagina 11 ...

Страница 13: ...lare 2 Se si vogliono modificare i valori premere i tasti SELECT e quindi ADJUST fino ad ottenere nuovi valori 3 Se si vuole cancellare l impostazione premere SELECT e quindi ADJUST finchè l indicazione dell ora diventa 4 Premere ENTER per confermare i nuovi valori impostati o le cancellazioni effettuate I PROG 3 I PROG 2 I PROG 3 0 PROG 3 12 90716584 11 05 2000 14 19 Pagina 12 ...

Страница 14: ...izzazione dell ora attuale Impostazione programma ferie 1 Premere il tasto MODE finchè compare la funzione ferie Ho Holiday 2 Premere il tasto SELECT inizia a lampeggiare l indicatore dei giorni I 0 3 S 13 90716584 11 05 2000 14 19 Pagina 13 ...

Страница 15: ...ore impostato ed automaticamente ricompare l indicazione dell ora attuale Comando contatti manovra manuale Tenendo premuto il comando manuale il relativo contatto sarà forzato a commutare anche se tale commutazione non è prevista dal programma Il programma si ristabilisce automaticamente al primo intervento automatico successivo alla manovra manuale I 0 3 S 14 90716584 11 05 2000 14 19 Pagina 14 ...

Страница 16: ...ne tolta 1 ora all ora attuale Funzione CALL Questa particolare funzione permette la programmazione del l orologio anche in assenza di alimentazione Per attivare tale funzione basta tenere premuto per almeno 2 s uno qualsiasi dei tasti ad esclusione del tasto C Il display si accende e si può impostare l ora attuale il programma e il programma ferie Se non si preme alcun tasto per circa un min il d...

Страница 17: ...one L installazione deve essere effettuata in conformità alle norme CEI vigenti Prima di operare sull impianto togliere tensione agendo sull interruttore generale Utilizzare conduttori isolati di colore giallo verde solo per il collegamento di terra Verificare che la sezione dei conduttori di alimentazione sia adeguata al carico alimentato ed in ogni caso non inferiore a 1 5 mm2 Serrare accuratame...

Страница 18: ...e ON OFF The switching program is developed both as a 24 hour program and as a 7 day program see Features These equipments are thus particularly suitable for heating and air conditioning installations of any kind sprinkling systems ligh ting installations electric signs etc 16584 16584 B 08484 with 1 OUTPUT CHANNEL has one out going relay with change over contact without potential rating 16 A 250 ...

Страница 19: ...t 25 C Intervention precision 1 s Operating temperature from 10 C to 55 C Insulation class II Liquid crystals display 37x21 mm dimensions Data display day hours minutes daylight saving time indication contacts position I on and 0 off permanent position indication P of the contact or contacts complete program set in days hours minutes with relevant contacts position indication of holidays when the ...

Страница 20: ...ting of the contact position indicated by P on the display the program is reset at the next manual change Output contacts 16 A 250 V cos f 1 8 A 250 V cos f 0 7 16584 08484 Change over contact without potential terminals 4 5 6 according to the diagram on the equipment 16585 08485 Two contacts with independent programming 1P ON OFF contacts without potential terminals 4 5 and 6 7 according to the d...

Страница 21: ...e Values adjustment Manual operation push button Memory total erasure Confirmation and control of selected programs Hours minutes days selector Daylight saving time setting P 0 I P 0 I TIME PROG 2 1 3 4 5 6 7 S Time display Program indication Day display or display of groups of days Permanent contact Daylight saving time ON contact closed OFF contact open 20 90716584 11 05 2000 14 19 Pagina 20 ...

Страница 22: ...s push button MODE to set the present time and day TIME will be displayed 3 Press the push button 1h to set the daylight saving time S will appear on the display to indicate the daylight saving time setting 4 Press push button SELECT the hours indicator will start flashing 0 0 1 TIME 1 TIME 1 S TIME 1 S 21 90716584 11 05 2000 14 19 Pagina 21 ...

Страница 23: ...ess push button SELECT the minute indicator will start flashing 7 Press push button ADJUST until the minutes indicator is set on 58 keeping the push button pressed for more than 1 s the visualization speed increases 8 Press push button SELECT the days indicator will start flashing TIME 1 S TIME 1 S TIME 1 S TIME 1 S 22 90716584 11 05 2000 14 19 Pagina 22 ...

Страница 24: ...JUST until the days indicator shows 3 Wednesday 10 Press push button ENTER the setting of the values is confirmed and operation will start at the selected time and day TIME S 3 S 3 0 0 23 90716584 11 05 2000 14 19 Pagina 23 ...

Страница 25: ... appear as in the figure ready to receive the time and day or group of days setting of I ON on channel A 3 Press push button SELECT the hours indicator starts flashing repeat steps from 5 to 10 included of the operating instructions While setting the day of the week if you keep the push button ADJUST pressed the groups of days will be displayed see next page 0 I PROG I PROG 1 PROG 1 0 24 90716584 ...

Страница 26: ...E to visualize again the present time 2 2 1 1 3 3 4 4 5 5 6 6 7 2 1 3 4 5 6 2 1 3 4 5 2 1 3 4 5 6 7 6 7 7 Monday The operation is set for GROUPS OF DAYS Every day of the week From Monday to Saturday From Monday to Friday From Monday to Thursday From Friday to Sunday Only Saturday and Sunday Tuesday Wednesday Thursday Friday Saturday Sunday I PROG 1 I 3 S 25 90716584 11 05 2000 14 19 Pagina 25 ...

Страница 27: ...er having programmed channel A press MODE push button again PROG will be displayed as well as symbols I On and O OFF of the contact and the channel B memory still available the total number of switching sequences is always 30 3 Set the desired programmations repeating steps from 2 to 5 included of the operating instructions for the 1 channel time delay switch PROG 0 I 26 90716584 11 05 2000 14 19 ...

Страница 28: ... Press push button ENTER all programmed settings will appear in sequence 3 In this way the time delay switch will indicate to have completed the display of the program setting 4 Press push button MODE the current time will appear on the display 0 I PROG I PROG 3 I PROG 1 0 0 3 S 27 90716584 11 05 2000 14 19 Pagina 27 ...

Страница 29: ...ars 2 If values have to be changed press push buttons SELECT and then ADJUST until you obtain the new values 3 To erase a programmed setting press push buttons SELECT and then ADJU ST until the hours indication becomes 4 Press push button ENTER to confirm newly set values or cancellations I PROG 3 I PROG 2 I PROG 3 0 PROG 3 28 90716584 11 05 2000 14 19 Pagina 28 ...

Страница 30: ... the display of the current time Setting of a holiday program 1 Press push button MODE until the function Ho Holiday is displayed 2 Press push button SELECT the days indicator starts flashing I 0 3 S 29 90716584 11 05 2000 14 20 Pagina 29 ...

Страница 31: ...ue is confirmed and automatically the current time will be displayed Non permanent manual operation Keeping the push button for manual operation pressed the relevant contact will change over even if this operation is not in the program setting The program will automatically be reset at the first automatic switching sequence after the manual operation I 0 3 S 30 90716584 11 05 2000 14 20 Pagina 30 ...

Страница 32: ... symbol S disap pears and 1 hour time will be removed from the current time CALL function This particular function allows to program the time delay switch even in absence of supply To activate this function keep any push button except push button C pressed for at least 2 s The display will light up and it will be possible to set the current time the program and the holiday program If no push butto...

Страница 33: ...ng to in force Italian CEI specifications or equivalent rules for buildings electrical installations Disconnect the mains acting on the main switch before operating on the system Use the yellow green insulated conductors only for the connection to the earthing circuit Verify if the supply conductors cross sectional area is sufficient for the feeded load in any case it must never be less than 1 5 m...

Страница 34: ...hements ON et débranchements OFF La programmation peut être journalière ou hebdomadaire voir Caractéristiques Ils sont donc particulièrement utiles pour les installations de chauffage et de climatisation de tout genre pour installations d arrosage et d éclairage pour enseignes lumineuses etc Appareil à 1 SORTIE 16584 16584 B 08484 avec un relais en sortie à un contact inverseur sans potentiel de c...

Страница 35: ... 1 s Température de fonctionnement de 10 C à 55 C Classe d isolation II Affichage par cristaux liquides dimensions 37x21 mm Capacité d affichage jour heures minutes indication de l heure d été position des contacts I on et 0 off indication de position permanente P du des contact contacts programme complet sélectionné en jours heures minutes avec indication de la position des contacts indication de...

Страница 36: ...réglage permanent de la position du contact indiquée par P sur l affichage retour au programme à la successive commutation manuelle Contacts de sortie 16 A 250 V cos f 1 8 A 250 V cos f 0 7 16584 08484 contact inverseur sans potentiel bornes 4 5 6 selon le schéma sur l appareil 16585 08485 deux contacts à programmation indépendante 1P ON OFF sans potentiel bornes 4 5 et 6 7 selon le schéma sur l a...

Страница 37: ...urs Touche de commande manuelle Annullation totale de la mémoire Confirmation et vérification des programmes réglés Sélecteur heures minutes jours Programmation heure d été P 0 I P 0 I TIME PROG 2 1 3 4 5 6 7 S Indication heure Indication programme Indication du jour ou des groupes de jours Contact permanent Indication heure d été Contact ON I fermé Contact OFF 0 ouvert 36 90716584 11 05 2000 14 2...

Страница 38: ... sur MODE pour régler l heure et le jour actuels TIME sera affiché 3 Appuyer sur la touche 1h pour sélectionner l heure d été le symbole S qui indique l heure d été sera affiché 4 Appuyer sur SELECT l indicateur des heures commence à clignoter 0 0 1 TIME 1 TIME 1 S TIME 1 S 37 90716584 11 05 2000 14 20 Pagina 37 ...

Страница 39: ...ppuyer sur SELECT l indicateur des minutes commence à clignoter 7 Appuyer sur ADJUST jusqu au moment où l indicateur des minutes est sur 58 laisser enfoncé pour plus de 1 s pour un affichage à vitesse élevée 8 Appuyer sur SELECT l indicateur des jours commence à clignoter TIME 1 S TIME 1 S TIME 1 S TIME 1 S 38 90716584 11 05 2000 14 20 Pagina 38 ...

Страница 40: ...moment où l indicateur des jours indique 3 mercredi 10 Appuyer sur ENTER les valeurs réglées sont confirmées On obtiendra ainsi la mise en marche à l heure et au jour préfixés TIME S 3 S 3 0 0 39 90716584 11 05 2000 14 20 Pagina 39 ...

Страница 41: ...qué à la figure à côté prêt à recevoir la sélection de l heure et du jour ou groupe de jours de l action de I ON sur la sortie A 3 Appuyer sur SELECT l indicateur des heures commence à clignoter répéter les étapes de la mise en marche de 5 à 10 inclus Tandis que l on régle le jour en maintenant appuyé sur ADJUST on obtiendra l affichage des groupes de jours voir à la page suivante 0 I PROG I PROG ...

Страница 42: ...r MODE pour retourner à l affichage de l heure actuelle 2 2 1 1 3 3 4 4 5 5 6 6 7 2 1 3 4 5 6 2 1 3 4 5 2 1 3 4 5 6 7 6 7 7 Lundi L opération est sélectionée pour GROUPES DE JOURS Chaque jour de la semaine Du lundi au samedi Du lundi au vendredi Du lundi au jeudi Du vendredi au dimanche Le samedi et le dimanche Mardi Mercredi Jeudi Vendredi Samedi Dimanche I PROG 1 I 3 S 41 90716584 11 05 2000 14 ...

Страница 43: ...grammation de la sortie A appuyer de nouveau sur MODE on obtiendra l affichage de PROG des symboles I ON et O OFF du contact de la sortie B et de la mémoire encore disponible le numéro total des opérations des deux sorties est toujours 30 3 Sélectionner les opérations désirées en répétant les opérations de la programmation de l inter horaire 1 sortie de 2 à 5 inclus PROG 0 I 42 90716584 11 05 2000...

Страница 44: ... En appuyant sur ENTER l affichage défile toutes les programmations sélectionnées 3 L inter horaire montrera l affichage à côté pour indiquer d avoir terminé le défilement des programmations sélectionnées 4 Appuyer sur MODE on reviendra à l affichage de l heure actuelle 0 I PROG I PROG 3 I PROG 1 0 0 3 S 43 90716584 11 05 2000 14 20 Pagina 43 ...

Страница 45: ...2 Si des valeurs sont à changer appuyer sur SELECT et aprés sur ADJUST jusqu à obtenir les valeurs désirées 3 Si l on veut effacer une sélection appuyer sur SELECT et après sur ADJUST jusqu au moment où l affichage de l heure devient 4 Appuyer sur ENTER pour confirmer les nouvelles valeurs ou les effacements définis I PROG 3 I PROG 2 I PROG 3 0 PROG 3 44 90716584 11 05 2000 14 20 Pagina 44 ...

Страница 46: ...fichage de l heure actuelle Programme jours fériés 1 Appuyer sur MODE jusqu à l affichage de la fonction Ho Holiday jours fériés 2 Appuyer sur SELECT l indicateur des jours commence à clignoter I 0 3 S 45 90716584 11 05 2000 14 20 Pagina 45 ...

Страница 47: ...nfirmée et l on revient à l affichage de l heure actuelle Commande manuelle temporaire En maintenant pressé la touche pour la commande manuelle son contact est obligé à commuter même si cette opération n est pas prévue par le programme Le programme est automatiquement rétabli à la première manoeuvre automatique qui suit la commande manuelle I 0 3 S 46 90716584 11 05 2000 14 20 Pagina 46 ...

Страница 48: ... actuelle Fonction CALL Cette fonction permet la programmation de l inter horaire même si l alimentation est coupée Pour activer cette fonction il faut tenir pressée une touche quelconque excepté la touche C pour au moins 2 s L affichage s allume et il est possible de sélectionner l heure actuelle la programmation et le programme jours fériés Si aucune touche n est pressée pour 1 min environ l aff...

Страница 49: ...n vigueur ou normes équivalentes pour les installations électriques dans les bâtimentes Couper l alimentation en agissant sur l interrupteur général avant d intervenir sur l installation Utiliser les câbles isolés de couleur jaune verte seulement pour la connexion au circuit de terre Vérifier si la section des conducteurs d alimentation est suffisante pour la charge alimentée elle ne doit quand mê...

Страница 50: ...ca VI Tel 39 0424 488 600 Fax 39 0424 488 188 http www vimar it 800 862307 Numero Verde 16584 16584 B 16585 16585 B 08484 08485 8000 Orologio programmatore elettronico giornaliero settimanale Electronic time delay switch 24 hour 7 day program Interrupteur horaire programmable électronique journalier hebdomadaire 0005 0B 90716584 ...