background image

7

           Installation Rules - Standard Compliance

5. INSTALLATION RULES

Installation should be carried out in compliance with the current regulations 
regarding the installation of electrical systems in the country where the products 
are installed. 
-   Carefully read the instructions given in this document as they provide important information on safety for installation, use and maintenance. 

-  After removing the packing, check the integrity of the appliance. The packing materials (plastic bags, foam polystyrene, etc.) must not be left within the reach of 

children as they are a potential source of hazard. The system must be made in compliance with current CEI standards. 

-  Above the power supply there must be a bipolar circuit breaker that is easily accessible with a contact gap of at least 3mm. 
-  Before connecting the appliance make sure that the panel data conform to the data of the distribution network. 
- This appliance must be intended solely for the use for which it has been expressly designed, and that is for audio door entry systems. Any other use is to be con

-

sider improper and therefore dangerous. The manufacturer cannot be held liable for any damage deriving from improper, erroneous or unreasonable use. 

-  

Warning

: To prevent injury, this appliance must be secured to the floor/wall in accordance with the installation instructions. 

-  Before doing any cleaning or maintenance, disconnect the appliance from the electric supply mains, turning the system switch off. 

-  In the event of faulty and/or poor operation of the appliance, cut off the power supply with the switch and do not tamper with it. For any repair work, contact only 

a technical support centre authorised by the manufacturer. Failure to comply with the above may jeopardise the safety of the appliance. 

-  Do not obstruct the openings or slots for ventilation or heat disposal and do not subject the appliance to drips or splashes of water. 
-  The installer must make sure the user information is given on the derived appliances. 

-  All the appliances forming the system must be intended solely for the use for 
   which they have been designed. 

- The installer must make sure the user information is given on the appliances. 

- This document must always remain enclosed with the system’s documentation. 

6

.

 STANDARD COMPLIANCE

EMC directive 
Standards EN 61000-6-1, EN 61000-6-3

Содержание 02032

Страница 1: ...ili power supply unit for LEDs and CCTV type cameras with 10 5 V d c 13 5 V d c 18 V d c 35 VA output power supply 230 V 50 Hz installation on DIN rail 60715 TH35 occupies 4 modules of 17 5 mm Instructions manual ...

Страница 2: ... voltage 230Va c 50Hz Maximum input power 35VA Protection of the primary winding of the transformer PTC SIEMENS TYPE C860 Protection of the internal electronics and shorting on the outputs PTC SIEMENS TYPE C945 3 CONNECTIONS A B 18 V d c not stabilized with piloting 0 8A intermittent cycle 90 sec ON 90 sec OFF A B C 13 5 V d c stabilized with piloting 250mA intermittent cycle 90 sec ON 90 sec OFF ...

Страница 3: ...20Vd c Output voltage U 18Vd c 0 8A not stabilized N B Make a bridge between the terminals A and B 4 CONNECTION DIAGRAMS The following diagrams illustrate some examples of the main applications using the power supply unit 02032 Connection Diagrams 6 1 3 2 4 5 11 8 7 9 10 V 14 13 M 14 6 2 1 3 4 5 10 8 7 9 11 13 V M 14 6 2 1 5 4 3 10 9 7 8 13 12 12 12 11 M V oppure CN2 6E 6S 6P 6 7 AU 2 3 5 CN1 C A ...

Страница 4: ...r a number of buildings In this case the power supply unit delivers stabilized voltage with the command of the central power unit Art 6580 6581 6680 Input voltage I 5 to 13 Vd c Output voltage U 10 5Vd c 0 25A stabilized and protected against shorting N B Make a bridge between the terminals A B and D MONITOR TERMINAL BLOCKS NETWORK POWER SUPPLY ART 02032 TO THE VIDEO CAMERA TO THE POWER SUPPLY ART...

Страница 5: ...eras operating at 12Vd c The power unit always delivers 0 25A POWER SUPPLY ART 02032 RETE VIDEO CAMERA ART 5000 ART 5020 5A20 5B20 ART 5A10 5B10 5C10 NETWORK MONITOR TVCC PRI D U B A C I Vi Vu OFF ON 75 Ohm BNC VIDEO VIDEO CAMERA Art 5AL6 Art 5BL6 MONITOR TVCC NETWORK NETWORK POWER SUPPLY ART 02032 Connection Diagrams ...

Страница 6: ...ing The diagram shows the connection of the video signal amplifier Art 5559 in a CCTV system Input voltage I 0 V Output voltage U 13 5Vd c 0 25A stabilized and protected against shorting N B Make a bridge between the terminals B and C VIDEO CAMERA ART 5000 ART 5020 5A20 5B20 ART 5A10 5B10 5C10 NETWORK AMPLIFIER ART 5559 MONITOR TVCC POWER SUPPLY ART 02032 NETWORK Connection Diagrams ...

Страница 7: ... sider improper and therefore dangerous The manufacturer cannot be held liable for any damage deriving from improper erroneous or unreasonable use Warning To prevent injury this appliance must be secured to the floor wall in accordance with the installation instructions Before doing any cleaning or maintenance disconnect the appliance from the electric supply mains turning the system switch off In...

Страница 8: ...49400241A0 EN 02 1204 VIMAR Marostica Italy Viale Vicenza 14 I 36063 Marostica VI Tel 39 0424 488 600 Fax 39 0424 488 188 http www vimar eu ...

Отзывы: