ViM KDTA-R F400 Скачать руководство пользователя страница 5

 5/16 NT00000439-KDTA-F400-KDTR-F400-AN-210121

3.  INSTALLATION
3.1  Dimensions and weight

Horizontal discharge

 B

 Asp. G

 Asp. F

 Q

 M

 Fix. D

 C

 AH

 R

 Fix. E

 Ref. J

 Ref. H

 N

 102

 Réf. H

Vertical discharge

 M

 Q

 C  CV

 Asp. G

 Asp. F

 B

 Fix. D

 R

 Fix. E

 P

 Ref. H

 AV

 102

 Ref. H

Size AH

AV

B

C

CV

D

E

F

G

H

J

M

N

P

Q*

R*

200

993

981

595

703

742

555

680

400

500

258 182

249

392

500

28

125

250

1130

1118

727

784 824

679

766

500

600

324

209

221

411

569

28

125

280

1177

1168 824

776

816 780

777

600

700

362

230

146

379

609,5

28

125

315

1360 1329

896 876

916

860

767

600

700

408 281

221

416

683,5 28

125

355

1490 1457 1006

990

1030

966

897

700

800

457

321

221

476

744

28

125

400

1594 1565 1120 1036

1078

1071

926

800

900

509

353

184

471

753

28

125

450

1761 1734 1191

1119

1162 1143 1130

900

1000

570

381 184 486 825

39

182

500

1919

1891 1387

1222 1264 1340

1180

900

1000

640

467

249

521

964

39

182

560

1919

1891 1387

1269 1310 1340

1180

1000 1100

718

505

189

492

999

39

182

630

2132 2104 1575 1464 1473 1507 1016 1200 1300

806

566

177

567

1070

44

240

710

2292 2264 1765 1614 1623 1697 1176 1200 1400

900

661

286

617

1125

44

240

* PAVZ: anti-vibration pads delivered accessories

Size

Axis height

Weight **

KDTA

KDTR

standard

insulated

standard

insulated

200

112

60

73

60

73

250

132

70

77

70

77

280

132

84

101

87

104

315

132

110

134

110

134

355

160

145

175

145

175

400

160

210

247

210

247

450

180

230

275

230

275

500

200

290

342

295

347

560

200

316

360

328

372

630

200

451

515

467

531

710

200

541

619

561

639

** Fan weight (kg) without motor, with transmission.

Содержание KDTA-R F400

Страница 1: ...10121 INSTRUCTION MANUAL INSTALLATION WIRING COMMISSIONING MAINTENANCE AFNOR CERTIFICATION ISO 14001 Environnement AFNOR CERTIFICATION ISO 9001 Q u a l i t KDTA R F400 F400 120mn extraction fan unit B...

Страница 2: ...Handling 10 3 5 Casing assembly 10 4 ELECTRICAL CONNECTION 11 4 1 Preliminary precautions 11 4 2 Wiring without any safety switch 12 4 3 Wiring with a mounted and connected safety switch 13 4 4 Wirin...

Страница 3: ...g units are designed for smoke extraction and ventilation applications in residential buildings commercial buildings industrial and logistics buildings and covered car paks Interior or exterior instal...

Страница 4: ...to the replacement are the responsibility of the Customer Excluded from our warranty are defects linked to abnormal use or not in accordance with the recommendations in our instructions defects observ...

Страница 5: ...1036 1078 1071 926 800 900 509 353 184 471 753 28 125 450 1761 1734 1191 1119 1162 1143 1130 900 1000 570 381 184 486 825 39 182 500 1919 1891 1387 1222 1264 1340 1180 900 1000 640 467 249 521 964 39...

Страница 6: ...6 16 NT00000439 KDTA F400 KDTR F400 AN 210121 3 2 Accessory assembly diagrams AVRZ RCAZ TPKD VSKZ RRKZ RCAZ RCAZ PPVZ TPKD RCRZ RCAZ PPHZ VSKZ RRKZ TPKD RCAZ VSKZ RRKZ...

Страница 7: ...630 806 466 355 457 304 710 900 510 400 509 328 AxA E Exhaust side bird proof guard Model AVRZ Exhaust side bird proof guard Model AVRZ Exhaust side bird proof guard A E A E 200 260 50 450 572 50 250...

Страница 8: ...ular connection Outlet A D A D 200 260 355 450 572 710 250 326 400 500 642 800 280 364 500 560 720 900 315 410 500 630 808 1000 355 459 560 710 902 1250 400 511 630 B C A External roof Model TPKD Exte...

Страница 9: ...with pressure than a KDTR backward curved fan KDTA F400 RRKZ Pstat Pa Qv m3 h 30 25 Qv 1 5 Qv 4 Qv 3 Qv 2 15 Plage d utilisation volet RRKZ RRKZ airflow adjustment range KDTR F400 RRKZ Pstat Pa 15 12...

Страница 10: ...he transmission of vibrations Leave a minimum distance L of 60cm on the transmission side for any technical work to be performed Do not obstruct the ventilation slits on either side of the unit 3 5 2...

Страница 11: ...el Do not forget the earthing connection In addition the cables routing must be protected from mechanical aggressions when the connection is made to the motor s terminal box or to the unit s safety sw...

Страница 12: ...rs check the direction of rotation of the fan for the two speeds Three phase motors U1 V1 W1 V2 U2 W2 Moteur D230 Y400V Moteur 1V Alim tri 230Vac 50Hz PE L2 L3 L1 0 GV U1 V1 W1 V2 U2 W2 Moteur D230 Y4...

Страница 13: ...In order to start up the fan make sure that the whole unit including fan motor and transmission rotates freely and that there is no object that may be projected by the fan The unit must be connected...

Страница 14: ...en the lugs if necessary Pressure switch Check the electrical aeraulic connections Check the operation Control box Make sure that there are no defects check the connections in particular the ground co...

Страница 15: ...re that they press against the bottom of the 2 grooves so that the threading of the pulley is not damaged To reduce the rotation speed loosen the mobile flange To increase the rotation speed tighten t...

Страница 16: ...constant bid to improve equipment the manufacturer reserves the right to undertake any technical alteration without any notice VIM Les pr s de M gy Sud SOUDAN CS 60120 79401 ST MAIXENT L ECOLE CEDEX T...

Отзывы: