OFF: The automatic flush is disabled. Only manual flushing is possible via the sensor system.
•
SINGLE: The automatic flush is enabled but the full-flush volume is always used for this.
•
DUAL: The automatic flush is enabled and the system independently determines whether to
trigger a half or full-flush volume.
Flush delay in AUTO Flush mode
An automatic flush triggered because AUTO Flush mode is enabled takes place with a delay of five
seconds from the time the user has left the sensor detection zone.
Defining the adaptive flush volume in Dual AUTO Flush mode
The flush system independently determines whether to trigger a half or full-flush volume, based on
time and distance parameters.
If the user remained at close range for a minimum of 30 s but less than approx. 90 s, a half-flush
takes place. If the user remained at close range for at least 90 s, a full-flush takes place.
46
M.VILLEROY-BOCH.COM // V 0.6 // 23.10.2020 // 921100D7