Installation
EN-UK
P.15
7 Installation
Advice!
Before starting the installation of the remote controller, the electrical box has to be in-
stalled.
Advice!
Use modell no.: 86HS50ll of the electrical flush-mounted box.
The remote control assembly has been designed taking this box into account. When in the
end smaller box is used, there is a risk of components not fitting in (transformer and/or
back of the wall mount). When a bigger box is used, the wall mount might not cover up the
entire box.
7.1 Prior to installation
•
Ensure that the titles and wall bricks have been laid and pipes in the pit and water supply pipes have
been reserved prior to installation.
•
Angle valve for drainage shall be opened to clear impurities and sludge in the embedded pipe prior to
installation, so that the pipe will not be clogged and the product functions normally.
•
It shall be confirmed that the extended height of soil pipe on the ground and distance from its center
to the wall (Distance between the pit center and the wall) matches with the product.
•
Position of the angle valve and outlet is as shown in figure below.
1
Angle valve
•
Distance from the angle valve to the ground is
150 mm a minimum can't be less than 100 mm.
2
Power socket
3
Sewage drain outlet
Ø
110 mm inner diameter of the
pipe 5-10 mm over the ground.
4
Installation space width 1 m Length 1.2 m