background image

Installation

P.22

7.5 Installing the toilet

Follow the installation specification to fix the toilet as deteiled in the following steps. After completition,

connection between the connecting wire and toilet's connector should be made and screwed tightly. Orga-

nize extra exposed connecting wires.

Mark the installation positions:

1

Wall

2

Toilet contour stencil

3

Position of the soil pipe

4

Position for the ground screws

5

Floor flange contour

1. Mark the installation positions for the ground screw, the contour of floor flange and the toilet.

Using a marker pen with the installation stencil.

2. Remove the installation stencil.

Содержание 310000400465329

Страница 1: ...Installation instructions Intelligent toilet ViClean IR...

Страница 2: ...Registration Number 310105787241384 Copyright Villeroy Boch Trading Shanghai Co Ltd Liability The content of our pages has been prepared with great care However we cannot accept responsibility for the...

Страница 3: ...misuse 7 4 3 General safety instructions 8 5 Product Technical Specification 9 5 1 Dimensions of the toilet 10 6 Delivery contents 11 6 1 Standard delivery contents 11 7 Installation 15 7 1 Prior to...

Страница 4: ...nd operators Installers e g trained craftsmen and artisans Under authorisation by the operator these persons carry out work for which they have the necessary expertise gained from a professional educa...

Страница 5: ...modification disassembly and destruction of the product Damage or loss resulting from water stain retention sediments or foreign matter contained in a water system Damage or loss resulting from the qu...

Страница 6: ...an exhaust fan or air vent shall be installed to ensure sufficient airflow Intended use also includes compliance with all instructions in the installation instructions compliance with the inspection...

Страница 7: ...erwise it will cause damage to the LCD display or leakage of liquid crystals Do not modify the remote controller or it will cause damage electric leakage and citcuit fault of the remote controller Do...

Страница 8: ...ing of environmentally haz ardous materials Considerable damage to the environment can be caused by incorrect handling of environmentally hazardous materials especially incorrect disposal Recycle elec...

Страница 9: ...f soil pipe and wall 305 mm Sewage pipe inner di ameter 110 mm Toilet Drainage pattern Down drainage Cleaning flow 300 600 mL min Water pressure is 0 18 MPa Warm water heating way Instantaneous Water...

Страница 10: ...thermostat Waterproof rating IPX4 Hydraulic requirements 0 07 MPa dynamic pressure 0 75 MPa hydrostatic pres sure Water supply temperature requirements 4 35 C Ambient temperature requirements 4 40 C...

Страница 11: ...ery contents Check that delivery contents are complete and undamaged on arrival ViClean IR Main body Component Designation Quantity Main body 1 Ceramic fittings Component Designation Quantity Inlet wa...

Страница 12: ...ic fittings Component Designation Quantity Plastic expansion plug 10x50mm 2 Flat washer 22 x 8 7 x 1 mm 2 Rubber washer 25 x 10 x 1 mm 2 Nut M8 2 Remote controller and fittings Component Designation Q...

Страница 13: ...Delivery contents EN UK P 13 Remote controller and fittings Component Designation Quantity Adapter 1 Wall mount 1 Antitheft hook 1 Screw M4 x 8 2 Screw M4 x 14 2...

Страница 14: ...Delivery contents P 14 Accessories Component Designation Quantity IR Stencil 1 User manual 1 Installation manual 1...

Страница 15: ...d pipes in the pit and water supply pipes have been reserved prior to installation Angle valve for drainage shall be opened to clear impurities and sludge in the embedded pipe prior to installation so...

Страница 16: ...the steps in this manual without explicit approval Distance from the surface of ground and wall must be made watertight during installation the bot tom part of the toilet shall not be fixed and instal...

Страница 17: ...parts 1 Wall mount front 2 Antitheft hook 3 2x Screw M4 x 8 4 2x Screw M4 x 14 countersunk 5 Wall mount back 6 Adapter with micro usb plug Position of the wall mount box 1 Center point of installatio...

Страница 18: ...the cable bundle and the adapter 2 Once the box has been installed in the wall the adapter should be connected to the electric cable Power rating 220 240 V AC 50 Hz Take down the front cover 1 Wall m...

Страница 19: ...3 Once the adapter is inside the electric box the micro usb plug is inserted in wall mount back Installating the wall mount back 4 Once the micro USB cable has been inserted into the wall mount back t...

Страница 20: ...ount front 5 Once the main part of the wall holder has been screwed to the electricity box the cover of the wall hollder must be clicked on it Fix the remote controller to the wall mount optional 1 Sc...

Страница 21: ...t hook 2 Screw M4x8 6 Once the wall holder has been properly installed the remote can be hung 7 There is the option to use the antitheft hook and the screw M4x8 to fix it to the holder Otherwise it is...

Страница 22: ...ector should be made and screwed tightly Orga nize extra exposed connecting wires Mark the installation positions 1 Wall 2 Toilet contour stencil 3 Position of the soil pipe 4 Position for the ground...

Страница 23: ...atly at the marking position of the ground screw Using an impact drill 4 Fix a plastic expansion plug 10x50 mm and a ground screw M8x36 ST7 5x46mm with the ad justable spanner Preparation before fixin...

Страница 24: ...Floor flange 6 Install the wax ring Fixing the floor flange 1 Hexagon nut screw the nut tightly 2 Flat washer 3 Rubber washer 7 The outer contour of floor flange shall be aligned with the contour on...

Страница 25: ...et connection inlet Screw the nut tightly Fixing the toilet 1 Toilet contour 9 Carefully clean the ground surface of the installation area 10 Lift up and move the bottom of the toilet ceramic above th...

Страница 26: ...plying hose onto the angle valve Screw the nut tightly Advice Do not bend or twist water supplying hose excessively Check the tightness of the connection 13 Open the angle valve 14 Press the FLUSH but...

Страница 27: ...er the floor flange screws with plastic sheaths 18 Lock the screw tightly 19 Put on the screw cap Painting mold prevention sealant 20 Clean the ground surface around the bottom of the toilet ceramic U...

Страница 28: ...e circuit breaker 5 Test the function of rearwash and ladywash Warning Eletrocution from touching live components Severe injury and even death can be the consequences The power plug shall be plugged i...

Страница 29: ...caused by incorrect handling of environmentally hazardous materials especially incorrect disposal Recycle electronic equipment or dispose of properly Do not dispose of electronic equipment in the hous...

Страница 30: ...10 2015 Shades and dimensions subject to the usual tolerances We reserve the right to make technical modifica tions to the range and alter colours...

Отзывы: