background image

Features

•  Touch Tone control of four zones, expandable 

to 8 zones 

•  Switches line level signal to amplifiers or           

amplified signal to speakers (amplifier(s) not  
included) 

•  Balanced audio circuitry for low noise 

•  Night bell warble with adjustable level from     

contact closure or ringing analog station 

•  Input provided for background music 

•  Separate paging and background music level   

adjustments 

•  Background music automatically mutes in 

paged zone(s) in all but single amplifier mode 

•  All-call and five group call patterns, selected by  

Touch Tones 

•  Selectable page alert tone with adjustable level 

•  Interfaces with ringing analog station ports,    

paging ports and unused phone system trunk 
ports 

•  Disconnects on silence, CPC, busy, touch     

tone “#” or time-out 

•  Screw terminals for all input/output connections

•  Multiple zone paging for phone systems with   

paging ports, unused analog station ports or 
unused trunk inputs 

•  Multiple department manufacturing business 

•  Multi-level warehouse 

•  Multiple building office complex 

Applications

Specifications

Power: 

 120V AC/13.8V AC, 1.25A adapter 

provided

 

Dimensions: 

211mm x 160mm x 46mm (8.30" x 

6.30" x 1.80") 

Shipping Weight:  

 1.5 kg (3.2 lbs)

 

Environmental:  

0° C to 32° C (32° F to 90° F) 

with 5% to 95% non-condensing humidity 

 

Relay Contacts:   

5 Amps@30V DC/250V AC 

each (350W@70V, 200W@8Ohm)

 

REN:  

0.5 A

 

Artificial Talk Battery Voltage: 

 24V DC

 

Connections: 

 (32) cage clamp screw terminals 

Four Zone Paging Interface

The

 ZPI-4

 is a four-zone touch tone 

controlled paging system capable of 
switching a line level signal (600 ohms) to 
amplifiers, an amplified signal to 70V 
speakers, or an amplified signal (200 watts 
maximum) to 8 ohm speakers.  

The

 ZPI-4

 features balanced audio circuitry 

throughout for low noise and compatibility 
with balanced paging system inputs and 
outputs.There are separate level controls for 
paging and background music, and 
background music can be disabled on a 
per-zone basis. Also provided is a night bell 
with adjustable volume activated by a dry 
contact closure or a ringing analog 
PABX/KSU station. 

The 

ZPI-4

 is compatible with ringing analog 

PABX/KSU station ports (disconnects on 
silence, CPC, busy, Touch Tone “#” or time-out) 
as well as unused trunk inputs, and will 
interface directly with standard paging ports.

www.vikingelectronics.com 

Information: (715) 386-8861

DESIGNED, MANUFACTURED AND SUPPORTED IN THE USA

ZPI-4

 

Four Zone 

Paging Interface 

July 8, 2020

PRODUCT 

MANUAL

SECURITY & COMMUNICATION

VIKING

Содержание ZPI-4

Страница 1: ...30 x 1 80 Shipping Weight 1 5 kg 3 2 lbs Environmental 0 C to 32 C 32 F to 90 F with 5 to 95 non condensing humidity Relay Contacts 5 Amps 30V DC 250V AC each 350W 70V 200W 8Ohm REN 0 5 A Artificial...

Страница 2: ...2 3 on 4 5 OFF ON DIP Switches Note Remove these shunts to eliminate background music for each zone individually except Single Amplifier Mode IMPORTANT Electronic devices are susceptible to lightning...

Страница 3: ...BATT switch to the OFF position all the way to the left Step 3 Attach a pair of wires from the paging port to the TELCO IN screw terminals Step 4 Attach the background music source if required to the...

Страница 4: ...tputs and speakers Step 1 Attach the ZONE 1 screw terminals to the speaker s for Zone 1 Step 2 If background music is to be enabled on this zone ensure that the ZONE 1 music shunts are in place coveri...

Страница 5: ...ends input to this amp the amplified signal is returned and the ZPI 4 sends it to the correct zone s Advantages Up to a 350 watt amplifier may be used when driving 70V speakers only one amplifier is r...

Страница 6: ...e volumes will work independently Step 13 Set the TIME OUT ADJUSTMENT on the Secondary to the maximum time clockwise Step 14 Plug the power supply adapter into the power jack of the Secondary and the...

Страница 7: ...the ZPI 4 activates the selected zone s See table to the right Touch Tone Zone s 1 1 2 2 3 3 4 4 5 1 2 6 2 3 7 3 4 8 1 2 3 9 2 3 4 0 1 2 3 4 ALL Touch Tone Primary Unit Zone s 11 1 1 12 1 2 13 1 3 14...

Страница 8: ...ER EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY WHETHER IN AN ACTION BASED ON CONTRACT TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY OR ANY OTHER LEGAL THEORY ANY LIABILITY OF VIKING SHALL BE LIMITED...