Important:  Please read and follow

1.  Before beginning, please read these instructions completely and carefully.
2.  Do not remove permanently affixed labels, warnings, or plates from product.  This may void the warranty.
3.  Please observe all local and national codes and ordinances.
4.  Please ensure that this product is properly grounded.

5.  The installer should leave these instructions with the consumer who should retain for local inspector’s use and for

future reference.

Installation must conform with local codes or in the absence of codes, the National Fuel Gas Code, ANSI Z223.1-latest edition.

IN CANADA

:  Installation must be in accordance with the current CAN/CGA-B149.1, Natural Gas Installation Code or

CAN/CGA-B149.2, Propane Installation Code and/or local codes.

General Information

1.  WARNING:  This wok/cooker is not intended to be installed in or on recreational vehicles and/or boats.
2.  WARNING:  Keep any electrical supply cord and the fuel supply hose away from any heated surfaces.
3.  Keep the wok/cooker area clear and free from combustible materials, gasoline, and other flammable vapors and

liquids.

4.  When the wok/cooker is not in use, the gas supply must be turned off at the LP gas supply cylinder.
5.  The pressure regulator and hose assembly supplied with the wok/cooker must be used.  Replacement pressure

regulators and hose assemblies must be those specified by the manufacturer.

6.  Finding a leak is not a “do-it-yourself” procedure.  Some leaks can only be found with the burner control in the

“on” position and this must be done by a qualified technician.

7.  The LP supply cylinder to be used must be constructed and marked in accordance with the specifications for LP gas

cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339,
Cylinders, Spheres, and Tubes for the Transportation of Dangerous Goods.

8.  Gas Manifold Pressure:

Natural gas -

4.0” W.C.P.

LP/Propane -

10.0” W.C.P. 

If you smell gas:
1.  Shut off gas to the appliance.
2.  Extinguish any open flame.
3.  Open lid.
4.  If odor continues, immediately call your gas supplier or your

fire department.

1.  Do not store or use gasoline or other flammable vapors

and liquids in the vicinity of this or any other appliance.

2.  Any LP cylinder not connected for use shall not be stored

in the vicinity of this or any other appliance.

If not installed, operated and maintained in
accordance with the manufacturer’s instructions, this
product could expose you to substances in fuel or
fuel combustion which can cause death or serious
illness and which are known to cause cancer, birth
defects or other reproductive harm.

For example, benzene is a chemical which is
part of the gas supplied to the cooking
product.  It is consumed in the flame during
combustion.  However, exposure to a small
amount of benzene is possible if a gas leak
occurs.  Formaldehyde and soot are by-
products of incomplete combustion.  Properly
adjusted burners with a bluish rather than
yellow flame minimize incomplete combustion.

DANGER

WARNING

FOR YOUR SAFETY

Содержание VGWTO5241

Страница 1: ...Use Installation Guide Built In Gas Outdoor Wok Cooker...

Страница 2: ...k is not a do it yourself procedure Some leaks can only be found with the burner control in the on position and this must be done by a qualified technician 7 The LP supply cylinder to be used must be...

Страница 3: ...e utensil scorching the outside of the utensil and making cleanup harder 10 The flame of the surface burner should be adjusted to just cover the bottom of the pan or pot Excessive burner setting may c...

Страница 4: ...out Height 10 1 4 26 0 cm Gas Requirements Natural standard residential 1 2 1 3 cm ID gas service line LP Propane standard residential 1 2 1 3 cm ID gas service line or equipped with high capacity hos...

Страница 5: ...uction where an LP Propane tank is going to be used there MUST be some type of support braces cut out etc to prevent tank from moving within the installation The support must also allow the LP Propane...

Страница 6: ...s shut off valve must be installed in an easily accessible location All installer supplied parts must conform to local codes or in the absence of local codes with National Fuel Gas Code ANSI Z223 1 la...

Страница 7: ...o check on type and size of run and how deep to bury the lines If the gas line is too small the unit will not function properly To connect the supplied regulator assembly to the incoming flexible gas...

Страница 8: ...d size of run and how deep to bury the lines If the gas line is too small the unit will not function properly To connect the supplied regulator assembly to the incoming flexible gas line attach with a...

Страница 9: ...to the LP Propane tank Open the tank valve and check the connection between the regulator and the Type 1 QCC 1 fitting for leaks with a soapy water solution If bubbles appear tighten the connection R...

Страница 10: ...uce the air and to prevent a noisy flame that lifts off the burner 5 Turn the surface burners off 6 Tighten the air shutter screws 7 Replace the grate support and grate A B 3 4 1 91 cm Air Shutter Ori...

Страница 11: ...rs will ignite at any on position with the automatic reignition system If the flame goes out for any reason the burners will automatically reignite if the gas is still flowing When gas is permitted to...

Страница 12: ...the front right side interior of the unit Loosen the head screws to remove the lid which is connected to 8 AA batteries After replacing the batteries reattach the lid with the screws Replace the pan b...

Страница 13: ...graphics from the control panel Use hot soapy water and a soft clean cloth Control Knobs MAKE SURE THE CONTROL KNOBS POINT TO THE OFF POSITION BEFORE REMOVING Pull the knobs straight off Wash in dete...

Страница 14: ...owing information indicated below You will need it if service is ever required The serial number and model number for your wok cooker is located on the left rear side of the burner box Model Number __...

Страница 15: ...wner of the product during the term of the warranty and applies to products purchased and located in the United States and Canada Products must be purchased in the country where service is requested I...

Страница 16: ...093014 Viking Range LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit the Viking website at vikingrange com in the US or brigade ca...

Отзывы: