Cutout Width - Minimum 

26 3/4” (67.9 cm)

34 3/8” (87.3 cm)

Maximum

29 7/8” (75.9 cm)

35 7/8” (91.1 cm)

Cutout Height - Minimum

2 3/8” (6.0 cm)

Cutout Depth - Minimum

18 5/8” (47.3 cm)

Maximum

20 1/8” (51.1cm)

Overall Width

30 3/4” (78.1 cm)

36 3/4” (93.3 cm)

Overall Height from Bottom 

4 3/16” (10.5 cm)

Overall Depth from Rear

21” (53.3 cm)

Gas Requirements

To field convert from natural to LP/Propane, the orifice spuds and regulator must be physically
changed.  Order accessory kit (LPK2-VGSU).  Accepts standard residental 1/2” (1.3 cm) I.D. gas
service line.

Electrical Requirements

120 VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product.

Maximum Amp Usage

2.0 amps

Surface Burner Rating

Left Front- 14,000 Nat./13,500 LP (BTU)

Left Front-

14,000 Nat./13,500 LP (BTU)

(4.1 Nat./4.0 LP [kw])

(4.1 Nat./4.0 LP [kw])

Left Rear-   12,000 Nat./11,000 LP (BTU

Left Rear, Center Front, and Center Rear -     

(3.5 Nat./2.8 LP [kw])

12,000 Nat./11,000 LP (BTU

Right Rear-   9,100 Nat./LP (BTU)

(3.5 Nat./2.8 LP [kw])

(2.6 Nat./LP [kw})

Right Rear-      9,100 Nat./LP (BTU)

Right Front-  6,000 Nat./LP (BTU)

(2.6 Nat./LP [kw})

(1.8 Nat./LP [kw])

Right Front-     6,000 Nat./LP (BTU)

(1.8 Nat./LP [kw])

Approximate Shipping Weight

67 lb. (30.2 kg.)

80 lb. (36.0 kg)

BASIC SPECIFICATIONS

GENERAL INFORMATION

1.  

WARNING

::    The use of cabinets for storage above the appliance may result in a potential burn hazard.

Combustible items may ignite, metallic items may become hot and cause burns.  If a cabinet storage is to be
provided the risk can be reduced by installing a rangehood that projects horizontally a minimum of 5” (12.7 cm)
beyond the bottom of the cabinets.

2. 

WARNING

::    This appliance shall not be used for space heating.  This information is based on safety

considerations.

3.  All openings in the wall behind the appliance and in the floor under the appliance shall be sealed.
4.  Keep appliance area clear and free from combustible materials, gasoline, and other flammable vapors.
5.  Do not obstruct the flow of combustion and ventilation air.
6.  Disconnect the electrical supply to the appliance before servicing.
7.  When removing cooktop for cleaning and/or service;

A.  Shut off gas at main supply
B.  Disconnect AC power supply
C.  Disconnect gas line to the inlet pipe.
D.  Lift appliance out of cabinet cutout.

8.  

Electrical Requirement

Normal grounded household current, 120 volts, 60 Hz, 15 amps, single phase.  Electrical installation should
comply with national and local codes.

9.  

Air Supply and Ventilation

Means must be provided for any heavy-duty cooking appliance to exhaust combustion waste product to the
outside of the building.  It is recommended that the cooktop be set under a powered, vented exhaust hood. A
non-vented recirculating hood is not recommended. Nothing should obstruct the flow of combustion and
ventilation air.

10.  

Gas Manifold Pressure

Natural gas - 

5.0” W.C.P.

LP/Propane - 

10.0” W.C.P.

11.  

Flexible Connections

If the unit is to be installed with flexible couplings and/or quick disconnect fittings, the installer must use a
flexible connector of at least 1/2” I.D. (1.3 cm) NPT with suitable strain reliefs and comply with ANSI Z21.41
and Z21.69 standards. 

Содержание VGSU SERIES

Страница 1: ...censed plumber or gasfitter A T handle type manual gas valve must be installed in the gas supply line to the appliance 1 Do not store or use gasoline or other flammable vapors and liquids in the vicin...

Страница 2: ...cabinet storage is to be provided the risk can be reduced by installing a rangehood that projects horizontally a minimum of 5 12 7 cm beyond the bottom of the cabinets 2 WARNING This appliance shall...

Страница 3: ...ded Do not under any circumstances cut or remove the third ground prong from the power plug WOOD COMPOSITE OVERLAY INSTALLATION The bottom of the hood should be 30 76 2 cm min to 36 91 4 cm max above...

Страница 4: ...MUM CUTOUT DIMENSIONS 3 30 0 W W M MO OD DE EL LS S 3 36 6 W W M MO OD DE EL LS S 27 68 6 cm 26 3 4 67 9 cm 30 3 4 78 1 cm 23 1 4 59 1 cm 19 9 16 49 7 cm R RE EA AR R D DO OW WN ND DR RA AF FT T R RE...

Страница 5: ...cated approximately 6 15 2 cm below the countertop cutout and 12 30 5 cm from the right side of the cutout INSTALLATION OF COOKTOP 1 Remove the roll of gasket material from your packed with items 2 Tu...

Страница 6: ...d with a manometer natural gas requires 5 0 WCP and LP Propane requires 10 0 WCP Incoming line pressure upstream for the regulator must be 1 WCP higher than the manifold pressure in order to check the...

Страница 7: ...noisy that lift completely off the ports 3 An orifice that is out of line with the burner venturi 10 After adjusting the air shutters reverse steps 1 7 to return the cooktop to working condition LP PR...

Страница 8: ...y a qualified technician If it is not contact your dealer for the name of their authorized service agency in your area Gas conversions and initial installation adjustments are not the responsibility o...

Страница 9: ...ttp www vikingrange com Specifications subject to change without notice F1516L PS0504VR REPLACEMENT PARTS Only authorized replacement parts may be used in performing service on the cooktop Replacement...

Отзывы: